| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 67D EXECUTIVE PO IZZAT NAGAR SUNCITY VISTAR BAREILLY UTTAR PRADESH 243122 | BAREILLY | UTTAR PRADESH | 243122 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical 18 19 MUNESWAR PURAM PARA ALAMNAGAR BIHIND ROSE CHILDREN ACADEMIC LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
8 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC Shahjahanpur
Electy. Trans. Circle Shahjahanpur
Work
2024_UPTCL_919238_1
51 ETC(S)/2023-24
Open Tender
Electrical Works
Fixed-rate
90 days
Shahjahanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹14,000
23 Jul 2024
19 Mar 2024
9 Apr 2024
19 Mar 2024
8 Apr 2024
19 Mar 2024
19 Mar 2024 - 8 Apr 2024
Amount
TOWER ACCESSORIES
Number Plate
Danger Plate
Phase Plate in sets of red, blue and yellow for Tension towers
Pipe type earthing material per tower
HARDWARES SUITABLE FOR ACSR PANTHER
Single Tension fittings
Single Suspension fittings
CONDUCTOR ACCESSORIES SUITABLE FOR ACSR PANTHER
Vibration Dampers
Mid Span compression Joint
Repair sleeves
HARDWARES & ACCESSORIES FOR GS EARTHWIRE 7/3.25MM
Tension clamp
Vibration Damper
Copper Bond
Supply of various Items required for erection of structures and equipments for 132 kV TBC Bayb 132 kV Shahjahanpur Bay at Sub-Station.
Supply of PG Clamps duly made of LM-6 aluminium alloy suitable For ACSR Panther to Panter Conductor, complete with 04 No. G.I. Bolts, Nuts, Spring & Plain Washers, as per Sample.
Supply of 132kV Isolator Bi-Metallic Terminal Connector duly made of LM-6 Aluminium Alloy, suitable for 132KV Isolator & Twin ACSR Panther Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specifications & Sample.
Supply of 132kV C.B. Terminal Connector duly made of LM-6 Aluminium Alloy, suitable for 132KV C.B. & Twin AC5R Panther Conductors, complete with 4 No, 12 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Technical Specificafions & Sample.
Supply of 132kV C.T. Bi-Metallic Terminal Connector duly made of LM-6 Aluminium Alloy along with Bi-Metallic Sleeve / Plate, suitable for 132KV C.T. & Twin ACSR Panther Conductors, complete with 4 No. 12 mm size G.I. Bolts, Nuts & Spring /Plain Washers, as per Technical Specifications & Sample.
Supply of 132kV Post insulator Clamp duly Made of LM-6 Aluminium AlJoy,suitable for 132KV Post Insulator & Twin ACSR Panther Conductor, complete with G.l. BoJts,Nuts, Spring & Plain Washers, as per Sample.
Supply of 120kV L.A. Clamp duly Made of LM-6 Aluminium Alloy, suitable for 120I£V L.A. & Twin ACSR Panther Conductor, complete with G.I. Bolts, nuts, Spring & Plain Washers, asper Sample.
Supply of 132kV P.T. Clamp duly Made of LM-6 Aluminium Alloy,suitable for 132KV P.T. & Twin ACSR Panther Conductor, complete with G.I. Bolts, Nuts, Sqring & Plain Washers, as per Sample.
ERECTION WORK
Survey including preparation of schedule of materials, marking of locations (Route length),GPS Survey of line with co-ordinates of each tower(The length of line shall be authenticated by GPS Survey)
Check survey
Cost of excavation of foundation pits including all earth work, backfilling and levelling etc. for
Setting of stubs including all foundation work but excluding the cost of concerting and excavation (Rate per location) for following towers :
132 KV DC/DE Panther
Cost of concreting of all type of tower foundation including cost of cement, dewatering,shoring,and shuttering,forming,curring but excluding cost of reinforcement bars
1:2:4 concreting
Erection of Superstructure of 132KV Towers and Anchor tower and their extensions wherever required including all work above ground level excluding hoisting of insulators, hardware & accessories, but including fitting of danger number, phase plates, bird guard and fixing & punching for 132KV SC/DC lines
Tack welding of all the bolts up to the height of one section of the tower or 5 meter from ground level whichever is higher with three tacks at 1200seperatiion of minimum 10 mm thickness with 10mm/12 mm electrode & application of Zinc rich Aluminium paint on the affected surface including cost of all material including tack welding of River Crossing tower & Anchor towers.
Installation of steel reinforcement bars in R.C.C. foundation including cost of steel reinforcement bars with cutting, bending, placing, binding etc. as per curent market rate.
Laying, stringing, tensioning clamping, jointing etc of ACSR ‘Panther’ conductor including hoisting of insulators , fitting of all necessary hardware and accessories i.e. fittings Armour rods, vibration dampers etc.on all three phases of 132 KV DC Towers.
Laying & stringing of 7/10 SWG EW including fixing of all kind of hardwares on 132 KV Lines.
Grounding work including earth work etc for pipe type grounding including cost of coke & salt.
Arrangment of back stay at different location where ever is required With the help of 18mm wire rope at 3 phase separately to avoid tower collapse/bend at the time of the de?stringing of conductor
Safe Loading, carriage and unloading of conductor and earthwire from store to site and other accessories etc.
Safe Sorting, Loading, carriage and unloading of tower Structure from store to site.
Opening of existing junipers of Single ACSR Panther Conductor between existing 132KV Main Bus Bar to 132KV BI and 132KV Transfer Bus to 132kV BI in in 02 No. 132Kv Bays. (1 Job per Bay)
Dismantling of Following Structures & Equipments including their Shifting in switchyard one Bay to Another at 132 kV S/S Tilhar by using hydra if required.
Lattice type Main & Aux. Structures
132 kV Post Insulator
132 kV Tendom Isolator with associated Pls
132 kV C.T. Junction Box
132 kV P.T. Junction Box
Erection of Following Structures & Equipments including their Shifting from Storage Place at the Suh Station to Erection Site :
Lattice type Main & Aux. Structures
132 kV Tendom Isolator with associated Pls
133 kV Bus Isolator with associated Pls
132 kV C.T. Junction Box
132 kV P.T. Junction Box
Jumpering of Equipment’s of Following I32KV Bays with the help of Single ACSR Panther Conductors to Connect the Bus Bar Conductors of 132KV Main Bus & 132KV Transfer Bus with Equipment’s and Equipment’s to Equipment's with the help of suitable Clamps /Connectors including, Cutting, Bending, Shaping etc. of the Conductor as per Site Requirement and material will be provided by Department.
Jumpering of 132KV Feeder Bay with Main and Transfer Bus including equipments.
Jumpering of 132KV TBC Bay with Main and Transfer Bus including equipments.
Jumpering of 132KV Section Isolator with 132 kV Main Bus after splitting of Main Bus.
Opening of cable terminations of 132 kV Bays and shifting different sizes cables from 132 kV SPN-Tilhar Bay to 132 kV Transfer Bay and making of cable schedule for re-termination.
132 kV TBC Bay
133 kV Feeder Bay
Laying of Following sizes Control Cables in Cable Trenches from Control & Relay Panels in Control Room to various Equipments, Junctions Boxes etc. in Switchyard as per Cable Schedule including Shifting of Cables in Drums from Storage Place at the Sub Station to Erection Site and Shifting Back the Balance Cables to Stores at the Sub Station.
Interconnection & Termination of various sizes above laid Control Cables between Feeder C&R Panel/DPP to various Equipments and Equipments to Equipments in 132kV Bays including Extending D.C. Supply from DCDB and AC Supply from ACDB to C&R Panel / DPP and Equipnients including Mal‹ing neccssary Holcs In Glands plates, wherever required alongwith provlding & fixing of Appropriate sizes Cable Glands, Providing of Ferrules for ech Core of the Cables, then Termination with Crimplng type Copper Lugs includes providing of the same for completion of the job.
Cable Termination in 132kV TBC Bay
Cable Termination in 132kV Shahjahanpur Bay
Making of Shielding Mesh for 132kV LAs in 132KV Shahjahanpur Bay by Fabrication of 3 Meter 1.ong Electrodes with 40 mm dia. M.S. Rod Bar having 150 mm long Conical shape and then its Piercing Vertically in the Ground with Top 500 mm below Ground Level, Jointing the Electrodes with 75 x 10 mm size M.S. Flat by Welding for making of Mesh, Connecting the Shielding Mesh with Main Earth Mat at 2 Places and finally, Painting of the Shielding Mesh /Earthing Strips with Anti-Corrosive Paint, with due Digging of Earth / Trench & its Back Filling and material will be provided by Department.
Earthing of Main & Aux. Structures and equipments(Isolators, CTs, PTs,LA, Junction Boxes etc.) with 50 x 6 mm size M.S. Flat
Earthing of Cable Trench with 25x6 mm slze M.S. Flat
Painting of M.S. Earthing Strips by Rubbing with Sand Paper & Wire Brush, then Painting with 1 Coat of Red Oxide Primer & 2 Coats (The 2nd Coat of Paint shall be Applied at the Gap of 48 hrs.when 1st Coat of Paint is Done & Checked by concerned J.E.) of 1st Quality Synthetic Enamel Paint of Asian / Berger / Nerolac make in Bus Green Colour as per Details below :
50 x 6 mm size M.S. Earthing Strip in Bus Green Colour
25 x 6 rnrn size M.S. Earthing Strip in Bus Green Colour
M/S DHIRENDRA SINGH
EMC Associates
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .