Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | ₹13.4 L Quoted ₹15.7 L | L1 | Accepted-AOC Lowest hence accepted |
| 2 | L2₹18.3 L+₹2.7 L (17.2%)Rejected-AOC | ₹18.3 L+₹2.7 L (17.2%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹19.0 L+₹3.3 L (21.3%)Rejected-AOC | ₹19.0 L+₹3.3 L (21.3%) | L3 | Rejected-AOC Not lowest |
| 4 | L4₹21.0 L+₹5.3 L (34.0%)Rejected-AOC | ₹21.0 L+₹5.3 L (34.0%) | L4 | Rejected-AOC Not lowest |
| 5 | L5₹23.7 L+₹8.0 L (51.3%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹23.7 L+₹8.0 L (51.3%) | L5 | Rejected-AOC Not lowest |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
21 Mar 2020, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
REPAIR REPLACEMENT OF CEILING FANS GEYSERS EXHAUST FANS AND WALL MOUNTED FANS AT ARTY CENTRE ASIF NAGAR AND MH MD AREA UNDER GE GOLCONDA
2020_MES_322400_2
GE/GOL/Token No.30 of 2019-2020
Open Tender
Civil Works
Item Rate
270 days
GE GOLCONDA
Application for tender
DD in favour of GE Golconda
EMD for UE contractors
Enlistment letter
For UE contractors documents meeting enlistment criteria as per NIT
GST registration No
Provident fund No
Electrical license issued by State Govt
7 documents required · 7 mandatory
₹500
GE GOLCONDA
₹39,000
Yes
29 Jun 2020
27 Feb 2020
23 Mar 2020
27 Feb 2020
21 Mar 2020
7 Mar 2020
27 Feb 2020 - 5 Mar 2020
Amount
Disconnecting and removing ceiling fan /wall mounting fan/exhaust fan from any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine & replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including testing complete all as specified and directed *NOTE :- (1) Necessary replacement of unserviceable parts/winding shall be measured and paid seperately. (2)Labour element for replacing of unserviceable parts deemed to be included in rate quoted.
Supply only oil filled Capacitor, 2.5 mfd suitable for ceiling fan/ exhaust fan
Supply only oil filled Capacitor 4 mfd suitable for exhaust fan
Supply only Ball bearing suitable for ceiling fans /wall mounting fan/ exhaust fan including necessary greasing. Make: NBC/SKF/TATA
Supply only bushing suitable for ceiling fans /wall mounting fan/ exhaust fan
Supply only Rubber bush with clamp, nuts and bolts for ceiling fan
Supply only shaft made out of carbon steel including necessary lathe work for ceiling fan
Taking out defective winding and rewinding of the ceiling fan of any sweep complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer's design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and directed
All as per Item No. 30 here-in-before but for exhaust fan of 225 to 305mm sweep
All as per Item No. 30 here-in-before but for exhaust fan of 330 to 400mm sweep
All as per Item No. 30 here-in-before but for exhaust fan of 450mm sweep
All as per Item No. 30 here-in-before but for air circulator fan of any sweep
M & L for spray painting the Ceiling Fan/wall mounting fan and accessories of any make / model / sweep with one coat of synthetic enamel DUCO paint (white colour) complete all as specified and directed.
M & L for spray painting the Exhaust Fan/air circulator fan and accessories of any make / mode/sweep with one coat of synthetic enamel paint (smoke gray colour) complete all as specified and directed.
Taking down water heater (Electric Geyser) of any type /make of 25/50 Ltrs capaciry after disconneting the existing electric wire , water pipe , inspecting the inner tank and components for necessary repairs including cleaning and removal of scales etc servcing etc and re-assembling in all respects after replacing unsv parts/components and testing for proper working after repairs and fixing in the original place/ position duly connecting up water supply and electric supply complete including civil work for grouting etc all as specified and directed. *NOTE:- (I) Necessary repairs /replacement parts shall be measured and paid seperately . (ii) Labour for replacing of unserviceable spare parts deemed to be included in rate quoted.
Supply & fix chromium plated connecting pipe with two brass adopters and brass flexible tubing for Hot water pipe connection for geyser complete all as specified and directed.
Supply & fix PVC cold water connection pipe with 2 Nos brass adopters/ check nuts for geyser complete all as specified and directed.
Supply & fix non return valve 15/20mm dia for cold water connection of geyser complete all as specified and directed.
Supply & fix Pressure release valve suitable for 25 Ltrs capacity Geyser complete all as specified and directed.
All as per item No. 43 here-in-before but 50 Ltrs capacity
Supply & fix thermostat including rubber gasket for 25 litres capacity geyser complete all as specified and directed.
All as per item No. 45 here-in-before but 50 Ltrs capacity
Supply & fix Indicator bulb neon AC 230 Volts (Round/Square) complete all as specified and directed.
Supply & fix Heating Element 1500 Watts including rubber/ PVC gasket of push type/threaded /round /triangle base type (as per sample) complete all as specified and directed.
Supply & fix Heating Element 2000 Watts including rubber/ PVC gasket of push type/threaded /round /triangle base type (as per sample) complete all as specified and directed.
supply only Apparatus plate base assembly complete with drain plug and fixing element including clamps for geyser of 50 lit capacity complete all as specified and directed.
supply only Apparatus plate base assembly complete with drain plug and fixing element including clamps for geyser of 25 lit capacity complete all as specified and directed.
supply only for replacement of insulating material ( Glass wool 'A' class) for geyser of 25 lit capacity complete all as specified and directed.
supply only for replacement of insulating material ( Glass wool 'A' class) for geyser of 50 lit capacity complete all as specified and directed.
S & F GI tubing medium grade 15mm bore with all fittings fixed to wall / laid in floor and including making good the disturbed surface to match with the existing surface including dismantling existing air released valve pipe and making proper connection for hot air releasing system complete all as specified and directed.
S & F GI tubing medium grade 20mm bore with all fittings fixed to wall / laid in floor and including making good the disturbed surface to match with the existing surface including dismantling existing air released valve pipe and making proper connection for hot air releasing system complete all as specified and directed.
S&F in repairs bib tap 15 mm bore dia, chromium plated, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in replacement of 15A 3 pin plug top polycarbonate, AC, 240V complete all as specified and directed.
Supply only Fan blades suitable for existing ceiling fans complete all as specified and directed.
M&L fabricated of iron bands,straps,supports or stays for rain water ,ventilating pipes including bolts if required hooks(stay) heavy for large gates ,hook and pintle hinges,large hasps and staples ,chains,hand made slidings bolts clamps hold fasts,wall ties hook for hanging fans,plain angles cleats for securing purlins to wood trusses or rafters ,knee piece inserts two way and three way straps plate washers and similar small articles conforming to Fe 290 Gde E-165, including clamps nuts,bold,fixing and old one complete all as specified and directed
M&L fabricated ceilling fans down rod both side hole and fixing clamps arrangement size of 15mm heavy duty GI pipe of one feet including taking down old one and fixng complete all complete all as specified and directed
M&L fabricated ceilling fans down rod both side hole and fixing clamps arrangement size of 15mm heavy duty GI pipe of two feet including taking down old one and fixng complete all complete all as specified and directed
M&L fabricated ceilling fans down rod both side hole and fixing clamps arrangement size of 15mm heavy duty GI pipe of three feet including taking down old one and fixng complete all complete all as specified and directed
Amutha Constructions
SANJEEV CONSTRUCTIONS
M/S Veerabhadra Constructions
STANDARD AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .