Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 256 MUNDHELA KHURD NEW DELHI 73 | WEST | DELHI | 110008 | Admitted-Finance |
Tender Value
₹4.8 L
EMD Value
₹14,305
Closing Date
4 Oct 2021, 11:00 amClosed
Executive Engineer (Electrical)/South Zone
SOUTH DELHI MUNICIPAL CORPORATION Office of the Executive Engineer (Electrical)-IV MC Primary School, Police Colony Hauz Khas, New Delhi-110016
Providing and fixing of Drinking water Cooler and Air Conditioner at various locations in ward no.75-S, Tigri under South zone.
2021_SDMC_89514_1
NIT No.11 Item No.01 (2021-2022)
Open Tender
Electrical Works
Item Rate
30 days
TIGRI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹14,305
Yes
7 Oct 2021
27 Sept 2021
5 Oct 2021
27 Sept 2021
4 Oct 2021
27 Sept 2021
Amount
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1 KV grade confirming to IS 7098 of following sizes. 2 x10 sqmm
Supply and Fixing of Desert air cooler having with tank storage capacity 70-80 Ltr.& suitable for 230 V/50 Hz etc. as required.
Supplying & installation of 4 kVA rating voltage stabilizer with input voltage : single phase sine wave (160-260V) and output voltage : single phase sine wave (210-250V) complete as reqd
Supplying & fixing of full stainless steel body self contained drinking water cooler with cooling capacity 150 ltr per hr, storage capacity: 150 ltr & suitable for 230 V supply as reqd
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
Supplying and installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required.
Supply of Inverter split airconditioner with rotary air compressor (R-32/290 refrigerant), 100% Copper Condenser,Rated cooling capacity upto : 6300 (W), rating 2 Ton complete with outer unit as required (5 star rated)
Supply of Extra refrigerant copper pipe as required.
Supply of extra drainage pipe as reqd.
Supply of extra electric wire as required. The size and material of the wire should be same as of the flexible cable which comes with the air conditioner
Supply of iron stand as required
Installation charges of split air condtioner
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .