| 1 | L1₹29.9 LAccepted-AOC 316 VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹32.6 L+₹1.6 L (5.22%)Rejected-Finance 316 A VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹33.6 L+₹2.6 L (8.54%)Rejected-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹34.8 L+₹3.9 L (12.6%)Rejected-Finance H NO 2702 JHANDA CHCOWK PURANI BASTI RANJHI JABALPUR M P 482005 | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹35.2 L+₹4.3 L (13.8%)Rejected-Finance MANEGAON DIWAN BADA KHAMARIA JABALPUR M P PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
15 Oct 2024, 6:00 pmClosed
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
REPAIR OF PATH, DRAIN, CULVERT COMPOUND WALL GATE, JAFRI, WALL ETC OF UNRESTRICTED AND RESTRICTED OF 506 ABW UNDER AGE B/R-II OF GE (EAST) JABALPUR
2024_MES_675263_1
8688/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (East) Jabalpur
Class D Category a (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹98,000
Yes
6 Dec 2024
19 Sept 2024
17 Oct 2024
19 Sept 2024
15 Oct 2024
28 Sept 2024
19 Sept 2024 - 25 Sept 2024
Amount
UNRESTICTED AREA
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in Soft/loose soil etc complete all as specified and directed
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement Conc ( reinfored) in gound floor nexc 15 cm thick complete all as specified and directed
Demolition of cement Conc ( Unreinfored) in gound floor nexc 15 cm thick complete all as specified and directed
M&L for Hardcore broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate ) in foundatios, filling and mass - concrete.complete all as specified and directed.
M &L for RCC design mix M-25 (20 mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC design mix M-25 (20 mm graded aggregates) as in walls, retaining walls, basement walls and the like , any thickness ,above top of footings, including attached plasters and buttresses complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
M&L for Use and waste of formwork flat face to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished of concrete complete all as specified and directed.
M&L for Use and waste of formwork to flat face of walls , retaiing walls, abutment, parapets and staircase railing and similar work including attached pillaters, buttresses etc vertical or to better. rough finished of concrete complete all as specified and directed.
M&L for TMT reinforcement bars 10mm over dia including all cutting bending binding cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 5 mm thick in CM 1:3 and to be finished even and smooth without using extra cement complete all as specified and directed
M&L for Precast cement concrete block soild blocks PCC 1:2:4 type B-1 using 20 mm aggregated masonry with exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
M&L fo Brick work using Modular bricks fly ash' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. (only for soak well)
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed
S&Ffor PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in walls complete all as specified and directed.
M&L for Hand packing by brocken stone or boulders (any thickness) at back of walls over arches etc use as filter media. and raising (or lowering) to the required level ®
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete ) set in CM Internal dia of 600 any size complete all as specified and directed.
S&Ffor 600MM Dia reinforced concrete pipe class NP-3 with on collar per length of pipe complete all as specified and directed.
Dismantling fencing wire mesh, any type
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid drry or laid dry and pointed complete all as specified and directed
M&Lfor PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as specified and directed..
S&Ffor Rubber moulded casted Machine pressed precast concrete inter locking Paver Block any shape and size Conf. to IS:15658-2006 of 60mm thick M-35 grade with Grey cement and pigment complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
S & Ffor Precast( kerb stone) concrete block masonry of PCC (1:3:6) type C1 using 20mm graded aggregate and set in CM (1:4) complete (Machine pressed) to match the interlocking tile etc with and including necessary excavation, use & waste of form work for plain fair faces of concrete complete all as specified and directed.
fixing only Rubber moulded casted Machine pressed precast concrete inter locking Paver Block any shape and size Conf. to IS:15658-2006 of 60mm thick M-35 grade with Grey cement and pigment complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for colour rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments complete.incl 15 mm thick screed bed CM (1:6) complete all as specified and directed.
M&L for Machine pressed precast cement concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40Grade with Grey cement and pigment complete all as specified and directed.
M& L for Applying two coats of synthetic enamel paint on concrete /paver block old surfaces of any description, not otherwise, described, over 10cm width or girth including complete all as specified and directed.
M&L for 100 mm thick Cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate ) in floors and paving and using exta cement complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Taking out removing rubbish and incl CM 1:3 Broken glass coping on top of walls complete all as specified and directed.
M&L for PCC 1:2:4 B-2 Type using 20 mm graded stone aggregate Cement concrete in surface channels and drains complete all as specified and directed.
M&L for 1:2:4 type B-0 using 12.5 mm grade aggregate set in CM 1:4 precast cement concrete louvres and jallies, 35mm thick (mea sured solid), including all mould- ings including necessary work complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M&L for Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as complete all as specified and directed.
S&Ffor Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., conforming to Fe -290 Gde E-165 complete all as specified and directed.
S&F for Mild steel round bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ® Fe-410 -W (Gde . E-250 Quality -A complete all as specified and directed.
S&F for Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 10cm complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
S&F in repair , Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
M&L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F in repair for Steel Concentrina coil of super profile of 600 mm dia stress in position hot dipped Galvanised steel wire coated with CLR ante corrosive paint making dimond shape with the help of dove tail clip (18 SWG) the coil fixed with razor wire at points were coil touch the bottom layer wire with help of hog rings(14 SWG) with and including all fittings like fastener, clips, luggs rings etc as approved by Engr-in Charge complete all as specified and directed .
M&Lfor two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxzide primer incl preparation of surfaces complete all as specified and directed.
M&L for two coat of syntetic enamel paint over new steel surface of any description n exc 10 cm in width or girth not otherwise described over one coat red oxzide primer incl preparation of surfaces complete all as specified and directed.
M&L forApplying two coats of cement base paint, white or tinted on new wall plaster incl primer surface including preparation of surface complete all as specified and directed..
M&L for complete removal of existing treatment and applying two coats of cement base paint,incl primer on wall surface including preparation of surface.complete all as specified and directed.
M&L for preparation of old plastered or un-plastered surface including brooming down or, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by and applying one coat of white wash on walls complete all as specified and directed.
M&L for one subsequent coat of white wash over one coat of white wash applied by under Srl item No 55 above
Dismantling posts or struts (wood, steel or R.C.C.) anysection, including taking out embedded portion and making good disturbed groundcomplete all as specified and directed.
RESTICTED AREA
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in Soft/loose soil etc complete all as specified and directed
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement Conc ( reinfored) in gound floor nexc 15 cm thick complete all as specified and directed
Demolition of cement Conc ( Unreinfored) in gound floor nexc 15 cm thick complete all as specified and directed
M&L for Hardcore broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate ) in foundatios, filling and mass - concrete.complete all as specified and directed.
M &L for RCC design mix M-25 (20 mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed..
M&L for RCC design mix M-25 (20 mm graded aggregates) as in walls, retaining walls, basement walls and the like , any thickness ,above top of footings, including attached plasters and buttresses complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
M&L for Use and waste of formwork flat face to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished of concrete complete all as specified and directed.
M&L for Use and waste of formwork to flat face of walls , retaiing walls, abutment, parapets and staircase railing and similar work including attached pillaters, buttresses etc vertical or to better. rough finished of concrete complete all as specified and directed.
M&L forTMT reinforcement bars 10mm over dia including all cutting bending binding cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 5 mm thick in CM 1:3 and to be finished even and smooth without using extra cement complete all as specified and directed
M&L for Precast cement concrete block soild blocks PCC 1:2:4 type B-1 using 20 mm aggregated masonry with exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
M&L for Brick work using Modular bricks fly ash' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. (only for soak well)
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed
S&Ffor PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in walls complete all as specified and directed.
M&L for Hand packing by brocken stone or boulders (any thickness) at back of walls over arches etc use as filter media. and raising (or lowering) to the required level complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete ) set in CM Internal dia of pipe 600 MM size complete all as specified and directed.
S&Ffor 600MM Dia reinforced concrete pipe class NP-3 with on collar per length of pipe complete all as specified and directed.
Dismantling fencing wire mesh, any type
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid drry or laid dry and pointed complete all as specified and directed
M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as specified and directed.
S&F for Rubber moulded casted Machine pressed precast concrete inter locking Paver Block any shape and size Conf. to IS:15658-2006 of 60mm thick M-35 grade with Grey cement and pigment complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
S & F for Precast( kerb stone) concrete block masonry of PCC (1:3:6) type C1 using 20mm graded aggregate and set in CM (1:4) complete (Machine pressed) to match the interlocking tile etc with and including necessary excavation, use & waste of form work for plain fair faces of concrete complete all as specified and directed.
fixing only Rubber moulded casted Machine pressed precast concrete inter locking Paver Block any shape and size Conf. to IS:15658-2006 of 60mm thick M-35 grade with Grey cement and pigment complete all as specified and directed.
fixing only Precast( kerb stone) concrete block masonry of PCC (1:3:6) type C1 using 20mm graded aggregate and set in CM (1:6) complete (Machine pressed) to match the interlocking tile etc with and including necessary excavation, use & waste of form work for plain fair faces of concrete complete all as specified and directed.
M& L for Applying two coats of synthetic enamel paint on concrete /paver block old surfaces of any description, not otherwise, described, over 10cm width or girth including complete all as specified and directed.
M&L for 100 mm thick Cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate ) in floors and paving and using exta cement complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Taking out removing rubbish and incl CM 1:3 Broken glass coping on top of walls complete all as specified and directed.
M&L for PCC 1:2:4 B-2 Type using 20 mm graded stone aggregate Cement concrete in surface channels and drains complete all as specified and directed.
M&L for 1:2:4 type B-0 using 12.5 mm grade aggregate set in CM 1:4 precast cement concrete louvres and jallies, 35mm thick (mea sured solid), including all mould- ings including necessary work complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
M&L for Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed.
S&Ffor Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F for Mild steel round bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ® complete all as specified and directed.
S&Ffor Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 10cm complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
S&F, in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)complete all as specified and directed.
M&L forFramed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S& F in repair for Steel Concentrina coil of super profile of 600 mm dia stress in position hot dipped Galvanised steel wire coated with CLR ante corrosive paint making dimond shape with the help of dove tail clip (18 SWG) the coil fixed with razor wire at points were coil touch the bottom layer wire with help of hog rings(14 SWG) with and including all fittings like fastener, clips, luggs rings etc as approved by Engr-in Charge complete all as specified and directed .
M&L for two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxzide primer incl preparation of surfacescomplete all as specified and directed.
M&L for two coat of syntetic enamel paint over new steel surface of any description n exc 10 cm in width or girth not otherwise described over one coat red oxzide primer incl preparation of surfaces complete all as specified and directed.
M&L for Applying two coats of cement base paint, white or tinted on new wall plaster ncl primer surface including preparation of surface complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint,incl primer on wall surface including preparation of surface.complete all as specified and directed.
M&L for preparation of old plastered or un-plastered surface including brooming down or, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by Mechanicaly and applying one coat of white wash on walls complete all as specified and directed.
M&L for one subsequent coat of white wash over one coat of white wash applied by Mechanicaly under Srl item No 109 above
Material & Labour for Preparation of newly plastered surfaces of walls and apply three coat of white wash by Mechanicaly complete all as specified and directed.
M&L for colour rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments complete.incl 15 mm thick screed bed CM (1:6)complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Schedule of credit amount of Rs. 102050.00 to be deducted during AOC.
M/S A.P.M. CONSTRUCTION CO. (BID ID -3132470)
M/s Brij Constructions (BID ID -3137765)
R R VISHWAKARMA CONSTRUCTION CO (BID ID -3132701)
M/S BHATIA CONSTRUCTIONS (BID ID -3140249)
M/S N K SONKAR (BID ID -3132574)
m/s R K SETHI (BID ID -3139873)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .