| 1 | L1₹3.7 CrAdmitted-Finance | ₹3.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.8 CrAdmitted-Finance REVENUE WARD 8 8 2 220 GANDLA STREET SULLURU SULLURPET NELLORE ANDHRA PRADESH 524121 UDYAM AP 08 0000783 | SPSR NELLORE | ANDHRA PRADESH | 524121 | ₹3.8 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | - | - | Rejected-Technical Not meeting the NIT eligibility criteria of similar works and Bidding capacity. |
| Sl No | Description | Qty | Unit | shiv electric L1 | CHANDRA REDDY ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of 415 V, 5 wire,3 Phase min.continous current rating of 630 A at 50 deg. Celsius, min short circuit rating of 36 kA/ 1 sec with TP+N,MCCB/ACB incomer feeder (LSIG MP Based) with minimum rating of 630A,36kA, TP+N MCCB/ACB outgoing feeder (LSIG MP Based) with minimum rating of 250A,25kA (5 nos) and ETP grade copper busbar (99.9% purity) including multifunction meter in all feeders, Single front, Fixed type, Pedestal/Floor mounted, Thermoplastic Polycarbonate Enclosure min.IP65 & IK08 type Outdoor Feeder Pillar with MS Hot Dip Galvanized Canopy and double door comply with IEC-61439-1/2 as per the tender specification. (MS item,GI Flat,Insulation mat required for installation will be measured separately.) | 6 | No | 11,00,000 ₹66 L | 13,25,107 ₹79.5 L |
| 2.00 | Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of 415 V, , 5 wire,3 Phase min.continous current rating of 400 A at 50 deg. Celsius, min short circuit rating of 25 kA/ 1 sec with TP+N MCCB incomer feeder (TMD Based) with minimum rating of 400A,25kA,TP+N MCCB/MCB outgoing feeder (TMD Based) with minimum rating of 32A,25kA (4 nos),63A,25kA (4 nos),200A,25kA(4 nos.) and ETP grade copper busbar (99.9% purity)including multifunction meter ln incomer feeder, Single front, Fixed type, Floor mounted,indoor type, Thermoplastic Polycarbonate Enclosure min.IP54 & IK08 type indoor panel with moving arrangement comply with IEC-61439-1/2 as per the tender specification. (MS item,GI Flat,Insulation mat required for installation will be measured separately.) | 8 | No | 10,00,000 ₹80 L | 10,79,792 ₹86.4 L |
| 3.00 | Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of Internal arc ( min 85kA for 0.4 sec) tested 415 V, 3 Phase min.continous current rating of 630 A at 50 deg. Celsius, min short circuit rating of 50 kA/ 1 sec with 4P, motorised MCCB/ACB incomer feeder (LSIG MP Based) with minimum rating of 630A,50kA, 4P,MCCB outgoing feeder (TM Based O/C,S/C) with minimum rating of 100A,16kA (34 nos),200 A,16 kA (4 nos) and ETP grade copper busbar (99.9% purity)including multifunction meter in incomer feeder, Single front, fixed type, ,fully type tested,min.IP54,4B form of segregation,Pedestal/Floor mounted indoor panel comply with IEC-61439-1/2 as per the tender specification. (MS item required for installation will be measured separatly.) | 1 | No | 18,00,000 ₹18 L | 33,22,577 ₹33.2 L |
| 4.00 | Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of Internal arc ( min 85kA for 0.4 sec) tested 415 V, 3 Phase min.continous current rating of 400 A at 50 deg. Celsius, min short circuit rating of 50 kA/ 1 sec with 4P, motorised MCCB incomer feeder (LSIG MP Based) with minimum rating of 400A,50kA, 4P,MCCB outgoing feeder (TM Based O/C,S/C) with minimum rating of 100A,16kA (30 nos),200 A,16 kA (3 nos)and ETP grade copper busbar (99.9% purity)including multifunction meter in incomer feeder, Single front, fixed type, ,fully type tested,min.IP54,4B form of segregation,Pedestal/Floor mounted indoor panel comply with IEC-61439-1/2 as per the tender specification. (MS item required for installation will be measured separatly.) | 1 | No | 18,00,000 ₹18 L | 27,26,437 ₹27.3 L |
| 5.00 | Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of Internal arc ( min 85kA for 0.4 sec) tested 415 V, 3 Phase min.continous current rating of 400 A at 50 deg. Celsius, min short circuit rating of 50 kA/ 1 sec with motorised 4P MCCB incomer feeder (LSIG MP Based) with minimum rating of 400A,50kA, MCCB outgoing feeder (TM Based O/C,S/C) with minimum rating of 100A,16kA (24 nos),200 A,16 kA (3 nos) and ETP grade copper busbar (99.9% purity)including multifunction meter in incomer feeder, Single front, fixed type, ,fully type tested,min.IP54,4B form of segregation,Pedestal/Floor mounted indoor panel comply with IEC-61439-1/2 as per the tender specification. (MS item required for installation will be measured separatly.) | 1 | No | 18,00,000 ₹18 L | 16,79,195 ₹16.8 L |
| 6.00 | Shifting,site acceptance testing, and commissioning of 415 V, 3 Phase 630/800A Power panel (approx 1000Kg). (MS item will be measured separately) | 1 | No | 50,000 ₹50,000 | 20,000 ₹20,000 |
| 7.00 | Shifting,site acceptance testing, and commissioning of 415 V, 3 Phase 250A Power panel (approx 500Kg). (MS item will be measured separetely) | 3 | No | 25,000 ₹75,000 | 10,000 ₹30,000 |
| 8.00 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of one number PVC/XLPE insulated & sheathed Copper/Aluminium Conductor, armoured power Cables of following sizes in excavated trenches direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required..(Note: Cable will be issued free of cost by the department) Size:-3/3.5/4Core X above 240 & up to 400 sqmm (Note:Height of installation may vary from 3 m to 14 m) | 4,800 | Mtrs | 350 ₹16.8 L | 424 ₹20.4 L |
| 9.00 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/XLPE/HRPVC insulated, Stranded Copper/Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).Size:-3/3.5/4core X Upto 120 sqmm (Note:Height of installation may vary from 3 m to 14 m) | 19,530 | Mtrs | 100 ₹19.5 L | 68 ₹13.3 L |
| 10.00 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/XLPE/HRPVC insulated, Stranded Copper/Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).Size:-3/3.5/4Core X above 240 & up to 400 sqmm (Note:Height of installation may vary from 3 m to 14 m) | 2,700 | Mtrs | 250 ₹6.8 L | 125 ₹3.4 L |
Tender Value
₹3.4 Cr
EMD Value
₹6.7 L
Closing Date
20 Feb 2026, 6:00 pmClosed
Project director, FRFCF, NRB
Office of the Project Director, FRFCF-NRB, Kalpakkam.
Supply, installation, testing, Commissioning of feeder pillars, MLPPs, EMLPP and associated electrical works for establishment of power supply at FRP block-1,2, FRFCF, Kalpakkam
2026_BARC_895670_1
BARC/NRB/FRFCF/EL/ETR-023/25
Open Tender
Electrical Works
365 days
FRFCF, KALPAKKAM
Please refer tender document
8 documents required · 8 mandatory
₹0
₹6.7 L
10 Apr 2026
2 Feb 2026
25 Feb 2026
2 Feb 2026
20 Feb 2026
2 Feb 2026
2 Feb 2026 - 10 Feb 2026
Name of the Work: Supply, installation, testing, Commissioning of feeder pillars, MLPPs, EMLPP and associated electrical works for establishment of power supply at FRP block-1,2, FRFCF, Kalpakkam
NIT No. BARC/NRB/FRFCF/EL/ETR-023/25 NIT Value: ₹3, 37, 49, 121/-
S.No NIT Conditions Department Requirements as per NIT Enter the name of the Firm Filling Instructions
0.0 Eligiblity based on financial credentials
1.1 Form - A : Turnover in lakhs.
FY 2020-21 Certificate from CA Enter "the value of turnover in lakhs."
FY 2021-22 Certificate from CA
FY 2022-23 Certificate from CA
FY 2023-24 Certificate from CA
FY 2024-25 Certificate from CA
Average annual financial turn over in last 3 consecutive financial years. 50 % of Estimated cost (₹1,68,74,561/-)
1.2 Form -A : Profit or Loss Account statement in Rs.
FY 2020-21 Certificate from CA Enter "the value of profit/loss in rupees."
FY 2021-22 Certificate from CA
FY 2022-23 Certificate from CA
FY 2023-24 Certificate from CA
FY 2024-25 Certificate from CA
Incurred any loss for more than two years during the last five years ending 31/03/2025.
2.1 Solvency certificate. Shall be furnished and shall not be older than 1 year from tender opening date. Enter "Furnished/Not Furnished"
2.1.1 Value 40% of Estimated cost (₹1,34,99,648) Enter "the value of Solvency in Rs."
2.1.2 Name of the bank Enter "Name of the bank"
0.0 Eligiblity Criteria
One similar completed work - 80% of the estimated cost OR two similar completed works - 60% of the estimated cost OR three similar completed works - 40% of the estimated cost. Estimated cost = ₹ 3,37,49,121.00 80% = ₹ 2,69,99,297.00 60% = ₹ 2,02,49,473.00 40% = ₹ 1,34,99,648.00
3.1 Meeting the requirements Enter "80% work / 60% work / 40% work"
3.2 Similar nature of completed works details "Supply, Installation, testing and Commissioning of Panels/Switchboards of 415V or above”. The similar works should have been executed in India.
3.2.1 Name of the work-1 : Enter" name of the work as in work order"
Value of the Work done Actual value of work done at the completion of work
WO order no: Enter "work order no with date"
Stipulated date of Completion Enter" work completion date"
Actual date of Completion Enter" Actual work completion date"
3.2.2 Name of the work-2 : Enter" name of the work as in work order"
Value of the Work done Actual value of work done at the completion of work
WO order no: Enter "work order no with date"
Stipulated date of Completion Enter" work completion date"
Actual date of Completion Enter" Actual work completion date"
3.2.3 Name of the work-3 : Enter" name of the work as in work order"
Value of the Work done Actual value of work done at the completion of work
WO order no: Enter "work order no with date"
Stipulated date of Completion Enter" work completion date"
Actual date of Completion Enter" Actual work completion date"
3.3 Details of all similar works completed in all respects during the last seven years. Shall be furnished Enter "Furnished/Not Furnished"
3.4 Performance report of works referred . Shall be furnished Enter "Furnished/Not Furnished"
0.0 List of projects under execution or awarded. Shall be furnished Enter "Furnished/Not Furnished"
0.0 FORM E - Performance report of work (for each work to be submitted) Shall be furnished Enter "Furnished/Not Furnished"
0.0 Form-F : Structure and organization Shall be furnished Enter "Furnished/Not Furnished"
0.0 Form-G : Details of Technical and administrative personnel to be employed for the work Shall be furnished Enter "Furnished/Not Furnished"
0.0 Eligiblity based on structure of the firm
8.1 Whether the firm is joint venture? Shall not be joint venture Enter "Yes/No"
0.0 Eligiblity based on mandatory registrations
9.1 PAN No Shall be furnished Enter "PAN no"
9.2 GST Registration Certificate Shall be furnished Enter "GST no "
9.3 Bidding capacity in Rs. The bidding capacity of the contractor should be equal to or more than the estimated cost, i.e, ≥ ₹ 3,37,49,121.00/- Enter " The value of Bidding capacity as furnished "
9.4 Electrical license No and validity date shall be furnished with validity Enter" The license No and validity date of license"
0.0 Eligiblity based on fulfilling requirements of the Bid
10.1 Undertakings & declaration by the contractor Shall be furnished Enter "Furnished/Not Furnished"
0.0 Eligiblity based on fulfilling Technical requirements of the Bid
11.1 Tender specific OEM Authorisation letter for panels (item no:1 to 5) Shall be furnished Enter "Furnished/Not Furnished"
11.2 Enter the Make of equipment offered against item no:1 (Eletrical panels) Shall be furnished Enter "Make"
11.3 Enter the Make of equipment offered against item no:2 (Eletrical panels) Shall be furnished Enter "Make"
11.4 Enter the Make of equipment offered against item no:3 (Eletrical panels) Shall be furnished Enter "Make"
11.5 Enter the Make of equipment offered against item no:4 (Eletrical panels) Shall be furnished Enter "Make"
11.6 Enter the Make of equipment offered against item no:5 (Eletrical panels) Shall be furnished Enter "Make"
11.7 Enter the Make & Model of equipment offered against item no:15 (LED Fixures) Shall be furnished Enter "Make & Model"
11.8 Enter the Make and Model of equipment offered against item no:24 (LED Fixures) Shall be furnished Enter "Make & Model"
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Project Director, FRFCF, NRB, BARCF, Kalpakkam – 603102
Name of Work : Supply, installation, testing, Commissioning of feeder pillars, MLPPs, EMLPP and associated electrical works for establishment of power supply at FRP block-1,2, FRFCF, Kalpakkam.
NIT No. : BARC/NRB/FRFCF/EL/ETR-023/25
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE with TAX In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of 415 V, 5 wire,3 Phase min.continous current rating of 630 A at 50 deg. Celsius, min short circuit rating of 36 kA/ 1 sec with TP+N,MCCB/ACB incomer feeder (LSIG MP Based) with minimum rating of 630A,36kA, TP+N MCCB/ACB outgoing feeder (LSIG MP Based) with minimum rating of 250A,25kA (5 nos) and ETP grade copper busbar (99.9% purity) including multifunction meter in all feeders, Single front, Fixed type, Pedestal/Floor mounted, Thermoplastic Polycarbonate Enclosure min.IP65 & IK08 type Outdoor Feeder Pillar with MS Hot Dip Galvanized Canopy and double door comply with IEC-61439-1/2 as per the tender specification. (MS item,GI Flat,Insulation mat required for installation will be measured separately.) No Excess(+) Full Conversion INR
2 Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of 415 V, , 5 wire,3 Phase min.continous current rating of 400 A at 50 deg. Celsius, min short circuit rating of 25 kA/ 1 sec with TP+N MCCB incomer feeder (TMD Based) with minimum rating of 400A,25kA,TP+N MCCB/MCB outgoing feeder (TMD Based) with minimum rating of 32A,25kA (4 nos),63A,25kA (4 nos),200A,25kA(4 nos.) and ETP grade copper busbar (99.9% purity)including multifunction meter ln incomer feeder, Single front, Fixed type, Floor mounted,indoor type, Thermoplastic Polycarbonate Enclosure min.IP54 & IK08 type indoor panel with moving arrangement comply with IEC-61439-1/2 as per the tender specification. (MS item,GI Flat,Insulation mat required for installation will be measured separately.) No Excess(+) Full Conversion INR
3 Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of Internal arc ( min 85kA for 0.4 sec) tested 415 V, 3 Phase min.continous current rating of 630 A at 50 deg. Celsius, min short circuit rating of 50 kA/ 1 sec with 4P, motorised MCCB/ACB incomer feeder (LSIG MP Based) with minimum rating of 630A,50kA, 4P,MCCB outgoing feeder (TM Based O/C,S/C) with minimum rating of 100A,16kA (34 nos),200 A,16 kA (4 nos) and ETP grade copper busbar (99.9% purity)including multifunction meter in incomer feeder, Single front, fixed type, ,fully type tested,min.IP54,4B form of segregation,Pedestal/Floor mounted indoor panel comply with IEC-61439-1/2 as per the tender specification. (MS item required for installation will be measured separatly.) No Excess(+) Full Conversion INR
4 Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of Internal arc ( min 85kA for 0.4 sec) tested 415 V, 3 Phase min.continous current rating of 400 A at 50 deg. Celsius, min short circuit rating of 50 kA/ 1 sec with 4P, motorised MCCB incomer feeder (LSIG MP Based) with minimum rating of 400A,50kA, 4P,MCCB outgoing feeder (TM Based O/C,S/C) with minimum rating of 100A,16kA (30 nos),200 A,16 kA (3 nos)and ETP grade copper busbar (99.9% purity)including multifunction meter in incomer feeder, Single front, fixed type, ,fully type tested,min.IP54,4B form of segregation,Pedestal/Floor mounted indoor panel comply with IEC-61439-1/2 as per the tender specification. (MS item required for installation will be measured separatly.) No Excess(+) Full Conversion INR
5 Fabrication, assembling, Factory testing, supply, installation, site acceptance testing, and commissioning of Internal arc ( min 85kA for 0.4 sec) tested 415 V, 3 Phase min.continous current rating of 400 A at 50 deg. Celsius, min short circuit rating of 50 kA/ 1 sec with motorised 4P MCCB incomer feeder (LSIG MP Based) with minimum rating of 400A,50kA, MCCB outgoing feeder (TM Based O/C,S/C) with minimum rating of 100A,16kA (24 nos),200 A,16 kA (3 nos) and ETP grade copper busbar (99.9% purity)including multifunction meter in incomer feeder, Single front, fixed type, ,fully type tested,min.IP54,4B form of segregation,Pedestal/Floor mounted indoor panel comply with IEC-61439-1/2 as per the tender specification. (MS item required for installation will be measured separatly.) No Excess(+) Full Conversion INR
6 Shifting,site acceptance testing, and commissioning of 415 V, 3 Phase 630/800A Power panel (approx 1000Kg). (MS item will be measured separately) No Excess(+) Full Conversion INR
7 Shifting,site acceptance testing, and commissioning of 415 V, 3 Phase 250A Power panel (approx 500Kg). (MS item will be measured separetely) No Excess(+) Full Conversion INR
8 Loading, Transportation, Unloading at site, installation, Testing and Commissioning of one number PVC/XLPE insulated & sheathed Copper/Aluminium Conductor, armoured power Cables of following sizes in excavated trenches direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required..(Note: Cable will be issued free of cost by the department) Size:-3/3.5/4Core X above 240 & up to 400 sqmm (Note:Height of installation may vary from 3 m to 14 m) Mtrs Excess(+) Full Conversion INR
9 Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/XLPE/HRPVC insulated, Stranded Copper/Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).Size:-3/3.5/4core X Upto 120 sqmm (Note:Height of installation may vary from 3 m to 14 m) Mtrs Excess(+) Full Conversion INR
10 Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/XLPE/HRPVC insulated, Stranded Copper/Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).Size:-3/3.5/4Core X above 240 & up to 400 sqmm (Note:Height of installation may vary from 3 m to 14 m) Mtrs Excess(+) Full Conversion INR
11 End Termination of Aluminium/copper Conductor PVC/XLPE Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium/copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. Size:-3/3.5/4Core X up to 35 sqmm (Note:Height of installation may vary from 3 m to 14 m) Sets Excess(+) Full Conversion INR
12 End Termination of Aluminium/copper Conductor PVC/XLPE Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium/copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland.). 3/3.5/4Core X above 50 Sqmm & up to 120 Sqmm Sets Excess(+) Full Conversion INR
13 End Termination of Aluminium/copper Conductor PVC/XLPE Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium/copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland.) 3/3.5/4Core X above 240 Sqmm & up to 400 Sqmm Sets Excess(+) Full Conversion INR
14 Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Crimping type) for 3.5 Core Aluminium Conductor, 1.1 kV (E), PVC/XLPE insulated cables of following sizes as specified. Excavation will be measured separately .Size:3.5 Core x 400 Sq. mm Sets Excess(+) Full Conversion INR
15 Supply, installation, testing and commissioning of various types of LED Luminaries with colour temperature range from 5700 - 6500K,input voltage range 1ph,50Hz±3%,230V±10%,50,000 average operating hours Surface mounted/Suspended, LED outdoor flood type fixtures of Min. initial lumen output of 14000 lumen , Min.lumen efficacy of 140 lumen/watt, Max power consumption of 100 W,IP66 or above, complete with all fixtures & erection accessories in MS Embedded Parts/Brick masonry or RCC walls/RCC ceiling/column/beam/False ceiling/any civilstructures with required number and suitable sizes of anchor fasteners, SS rope, bolts and nuts with washers etc., along with necessary Scaffolding arrangement, safety measures etc., as per the detailed specifications, drawings and as directed by the Engineer-In-Charge.(Note:5 year Manufacturer warranty shall be provided for all supplied fixtures ) No Excess(+) Full Conversion INR
16 Supply, Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade 3C*2.5sq.mm HRPVC insulated & FRLS Multicore round sheathed Bright Annalead Copper conductor Heavy Duty Industrial grade Flexible cables in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification. Mtrs Excess(+) Full Conversion INR
17 Supply, fabrication and installation of 25 X 6 mm GI flat size of Hot dip Galvanised GI Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. No cutting or drilling permitted after galvanisation. (Note:Height of installation may vary from 3 m to 14 m) Mtrs Excess(+) Full Conversion INR
18 Supply and installation of 8 SWG copper wires in built in trench as per the detailed specification Mtrs Excess(+) Full Conversion INR
19 Supply and installation of 230 mm Dia. 2 Mtrs Long, NP 2 Class Hume Pipes at a depth of 1200 mm including supply of Collars and fixing them with1:1 cement mortar and curing, including cutting for crossing of existing road and excavation of all types of soil, backfilling, normalisation of road etc complete as directed by Engineer-in-Charge. Nos Excess(+) Full Conversion INR
20 Supply installation and testing of Maintenance free earthing system (1x10 feet x 5/8inch copper bonded steel rod, 22 kg Ground Enhancing Material (GEM) ) as per IS: 3043 including RCC Chamber and RCC cover slab as per detailed specification Nos Excess(+) Full Conversion INR
21 Supply installation of 2.0 mm thickness, Max useable voltage 3.3kV, AC Proof voltage 10kV for 3 minutes, AC dielectric strength 30kV RMS Insulating Mat confirming to IS:15652 Sq.Mt Excess(+) Full Conversion INR
22 Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. CuM Excess(+) Full Conversion INR
23 Supply,Fabrication and installation of GI supports for cable trays and painted supports for other application on wall/slabs/ floor/other civil structures which includes MS Brackets, Supports, Frame work, Clamps, Base Channels, sheets etc., fabricated out of angle / Channel / Rods etc., The rate quoted shall include the cost of fabrication / welding, cleaning and galvanising including supply of required, fasteners, nuts, washers,caterpins etc., (Note:Height of installation may vary from 3 m to 14 m) Kg Excess(+) Full Conversion INR
24 Supply, installation including end termination with existing wiring, testing and commissioning of recess, box (2 ft x 2 ft) type, low bay LED indoor fixtures of Min. initial lumen output of 3600 lumen, Min.lumen efficacy of 110 lumen/watt, Max power consumption of 34 W with colour temperature range from 5700 - 6500K,input voltage range 1ph,50Hz±3%,230V±10%,50,000 average operating hours as follows, complete with all fixtures & erection accessories in False ceiling/any civilstructures with required number and suitable sizes of anchor fasteners, SS rope, bolts and nuts with washers etc., along with necessary Scaffolding arrangement, safety measures etc., as per the detailed specifications, drawings and as directed by the Engineer-In-Charge.(Note:5 year Manufacturer warranty shall be provided for all supplied fixtures) (Note: Height of false ceiling is 3 to 5 mtr and distance between false ceiling and true ceiling of room is varies from 2 mtr to 10 mtr) Nos Excess(+) Full Conversion INR
25 Supply, installation, testing and commissioning of 600mm dia Industrial wall Mounting /pedestal Fans as per the detailed specification Nos Excess(+) Full Conversion INR
26 Installation of upto 6 sqmm of 1100V grade FRLS insulated copper conductor wires existing concealed/ Exposed PVC / ERW/Flo-coated Metal conduits as per the detailed scope of work including supply and installation of spacer and clamp wherever required (Note: installation height upto 12 m) Mtrs Excess(+) Full Conversion INR
27 Wiring for Light/Sensor/Fan Points with 2 Runs of 1.5 Sq.mm copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board to Primary light/sensor/fan point through Control Switch Box including 10Amps modular switch (Note: Average length per run considered is 30 mtr and installation height upto 12 m) Nos Excess(+) Full Conversion INR
28 Supply, installation, testing and commissioning of the 32A 3P+N+E-FP Tempra plug and socket DBs with FP 20A-32A MCB of Metal Clad Socket in sheet steel enclosure with Plugs and Socket as per the detailed specification. (MS item will be measured separately). Set Excess(+) Full Conversion INR
29 Supply, installation, testing and commissioning of the 16A 2P+E-DP Tempra plug and socket DBs with DP 16A MCB of Metal Clad Socket in sheet steel enclosure with Plugs and Socket as per the detailed specification. (MS item will be measured separately). Set Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select, Excess (+), Less (-)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_941425.pdf
techsummary_941425.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tenderdocuments023.pdf
Tender Documents • 0.65 MB
TechnicalBidETR023forms.xls
Additional Documents • 0.07 MB
sectionVIAnnexure-II.PDF
Additional Documents • 7.46 MB
Annexure-I.pdf
Additional Documents • 1.41 MB
GCC2014.pdf
Additional Documents • 4.88 MB
BOQ_941425.xls
BOQ • 0.30 MB
Annexure-II.pdf
Additional Documents • 0.42 MB
Download all tender documents and submit your bid