Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC being lowest and reasonable | |
| 2 | L2₹31.0 L+₹2.1 L (7.38%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹32.6 L+₹3.7 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹55,900
Closing Date
4 Mar 2023, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
PROVN OF CHAIN LINK FENCING NEAR BLDG NO T-142 TO T-T147 AND SPL REPAIR OF CHAIN LINK FENCING NEAR BLDG NO P-51 AT LICHUBARI AND SPL REPAIRS TO BLDG NO T-32 ASC(AF) AT ROWRIAH UNDER GE JORHAT
2023_MES_577698_1
8118/E8
Open Tender
Civil Works
Item Rate
180 days
Jorhat
Please refer tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER JORHAT
₹55,900
Yes
13 Mar 2023
28 Jan 2023
6 Mar 2023
28 Jan 2023
4 Mar 2023
14 Feb 2023
28 Jan 2023 - 2 Feb 2023
Amount
NOTES :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
Excavation in post holes not exceeding 0.5 cum and getting out and returning filling in, ramming earth in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good in hard/dense soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Material and labour for Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for Reinforced Cement Concrete-20 (Nominal mix) using 20 mm graded stone aggregate as in beams and Lintel Beam complete all as specified and directed.
Material and labour for Reinforced Cement Concrete M--20 (Nominal mix) using 20 mm graded stone aggregate as in chajja complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, lintels, cantilevers, shelves for flat surfaces complete all as specified and directed.
Use and waste of formwork to chajjas and similar items including edges.
Material and labour for TMT Bars Fe 500D 10mm dia & over cut to length bent to shape required inculding cranking bending spirally hooping for columns etc and binding with MS wire ennealed less than 0.9mm dia or securing with clip complete all as specified and directed.
Material and labour for TMT Bars Fe 500D 6mm dia & 8 mm dia cut to length bent to shape required inculding cranking bending spirally hooping for columns etc and binding with MS wire ennealed less than 0.9mm dia or securing with clip complete all as specified and directed.
Dismantling plain/corrugated steel sheeting, any guage, thickness including eves gutter / rain water pipe complete & removal all as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Material and labour for mild steel Rolled mild steel in roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including cleats Fe-410 W (Gde E-250) Quality-B including welding, nuts , bolts, one shop coat of zinc chromate primer after preparation of surface complete all as specified and directed.
Material and labour for Rolled mild hollow steel sections steel of grade YSt 310 conform to IS 4923-1997 in roof trusses (framed), trussed, purlins, bracing and fastenings including distance pieces, cleats etc.
Material and labour for mild steel screw bolts (machine made) with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 22.5 cm and not exceeding 30 cm long, dia of neck 16 to 20 mm complete all as specified and as directed
Material & labour of Mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410W (Gde- E- 250) quality- A complete all as specified and as directed
Supply and fixing of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fixing of pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screws complete all as specified and as directed.
Demolition of brick masonry built in cement sand mortar including all quoins, arches, pillars , etc complete all as specified and as directed.
Material and labour for Brick work with bricks class designation 75, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, size as per old size brick, straight or curved on plan exceeding 6 m mean radius half brick thick walls built in Cement Mortar 1:4 complete all as specified and as directed.
Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth without using extra cement to the plastered surface complete all as specified and as directed.
Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paid separately
Material and labour for Preparation of new plaster wall surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.0 mm thick cement base wall putty complete all as specified and directed.
Material and labour for preparation of new surfaces and and applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
Demolition of cement concrete ( un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
Material and labour for 75 mm thick plain cement concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in plinth protection, finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for75 mm thick plain cement concrete 7.5 (Nominal Mix) using 40 mm graded stone aggregate as in sub base floor complete all as specified and as directed.
Supply and fixing of steel windows with side hung shutters including hinges projecting type with steel handle and steel peg stay complete with gauged bars, dovetailed or welded complete all as specified and as directed
Supply and fixing in repairs of sheet glass 4 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
Material and labour for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girth complete all as specified and as directed..
Material and labour for Preparation of new steel surface and pplying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over not exceeding 10 cm in width or girth complete all as specified and as directed..
Material and labour for Mild Steel angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 (Gde E-165) complete all as specified and as directed..
Supply and fixing of chain Link 3 mm dia , 75mm x75mm mesh size of mild steel galvanized fencing and minimum weight 2.1 Kg per Sqm and including fixed with straining bolts incl provision of binding wire etc complete all as specified and as directed.
Material and labour for Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts complete all as specified and as directed.
Material and labour for Mild steel screw bolts (machine made) with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm and not exc 15 cm long, dia of neck 5 to 10 mm complete all as specified and as directed.
Material, labour for high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required including hooking ends for straining chain link fencing and fixed on fencing post complete all as specified and as directed
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground, embedded in natural ground complete all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground, embedded in concrete, brickwork, masonry etc. complete all as specified and as directed.
Dismantling barbed wire fencing any size
Dismantling fencing wire mesh, any type complete all as specified and as directed.
Subtotal of Sch A part-I
SCHEDULE 'A' PART - II FOR E/M PORTION (Sl No __ to ____)
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
Material and labour for concealed point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, FRLSH through and including 20 mm PVC conduit & its accessories, cadmium screws fixed in concealed surface of wall/ceiling/false ceiling and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable FRLSH as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick laminated sheet for housing complete switch for One light/fan/bell point controlled by one way switch. Note :- Cutting chases and making good in walls shall be deemed to be included in the unit rate.
All as per item no 121here-in-above but One 3 pin socket outlet 5 amps on the same board with other switches
All as per item no 121 here-in-above but above but for one 5 amp socket independent complete all as specified and as directed.
Material and labour for concealed point wiring complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, FRLSH through and including 20 mm PVC conduit & its accessories, cadmium screws fixed in concealed surface of wall/ceiling/false ceiling and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable FRLSH as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick laminated sheet for housing 3 pin socket outlet 15 Amp independent:- Note :- Cutting chases and making good in walls shall be deemed to be included in the unit rate.
Supply and fixing of switch piano flush single pole one way 5 amps complete all as specified and as directed.
Supply and fixing of socket outlet 3 pin 6 Amps 230 volts Universal type complete all as specified and as directed.
Supply and fixing of switch piano flush single pole one way 15 amps complete all as specified and as directed.
Supply and fixing of socket outlet 3 pin 6/15 Amps 230 volts Universal type complete all as specified and as directed.
Supply and fixing of Bell AC, 230 volts, single pole single pole one way 5 amps complete all as specified and as directed.
Supply and fixing of Bell multi music type AC 240 Volt complete all as specified and as directed.
Material and labour for Electronic type fan regulator step type 120 watt, 230 volt complete all as specified and as directed. Make : Code no 14502 of Anchor or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of sub main wiring with two single core 4.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including one single core 4.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Material and labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified and as directed. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Material and labour for laying of Class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as cable protection complete all as specified and as directed.
Material and labour for laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 16 Sqmm x 4 Core complete all as specified and as directed.
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC-M10 using 20 mm graded stone aggregate including bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system including disconnecting of electric connection both incoming & out going from existing unsv indoor/outdoor feeder pillar boxes/busbar enclosers and unsv accessories and taking out panel from the foundation . The panel board shall comprise of following items & all specified in SSR Part-I clause no 19.21 and all as shown on drawing .
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S GOPAL ROY AND CO
NIHAR ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .