Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC OLD SABZI MANDI PATHANKOT M S NORTHERN INDIA CONSTRUCTION CO DHANGU ROAD VILLAGE TOWN PATHANKOT CITY PATHANKOT PATHANKOT PUNJAB 145001 INDIA | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.9 L+₹5.4 L (30.8%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.8 L+₹11.3 L (64.4%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
3 Jan 2024, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REPR OF PERIMETR STRET SECURITY POST TOP LANTERNS AND GATE LIGHT MAINT OF DG SET CAPACITOR PANELS AND CRAN FIRE FIGHTNG PIPE LINE AT OTG AND BHADORIYA MILITARY COMPLEX UNDER GE S PATHANKOT
2023_MES_631191_1
GES/PKT/T-38/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹60,000
Yes
29 Feb 2024
5 Dec 2023
5 Jan 2024
5 Dec 2023
3 Jan 2024
20 Dec 2023
Amount
Maintenance and servicing of 100 KVA DG set consisting of replacement of fuel filter, air filter and lub oil filter including replacement of eninge oil and coolent oil complete all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM. Note: Engine oil and coolent oil will be measured and paid seperately.
All as per item No. 1 above but 50 to 63 KVA
Dismentling of self starter and supply and fix new self starter 12 V of capacity of suitable for 50 KVA to 100 KVA DG Set complete all as specified and directed.
M&L for repair and overhauling of unsv dynamo/ alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy suitable for 50 KVA to 100 KVA DG Set complete all as specified and directed.
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 50 to 100 KVA
M & L for repair of Water pump of 50 to 100 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 50 to100 KVA DG Set of any make and model complete all as directed.
M&L for overhauling and calliberation of fuel injector assembly including replacement of unsv/defective spares of 50 to 100 KVA DG Set of any make and model complete all as directed.
S&F in replacement battery leads set, PVC insulated multisranded, copper conductor of min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets of different capacities.
M&L for replacement of coolant for radiator for DG set at various locations.
M&L for replecement of Lub Oil (Engine Oil) of grade 20W40 for Engine for DG set at various locations.
M&L for replacement of starter ring gear assembly for capacity 50 to 100 KVA DG set.
S&F in replacement of existing wornout unserviceable fan belt with new fan belt suitable of existing DG Set capacity 50 to 100 KVA complete all as specified and directed.
Dismantaling Radiator of DG Set and Servicing / overhauling the same, making leak proof including soldering bracing cleaning the fins with antiscalent fixing on base frame capacity of 50 to 100 KVA DG Set complete all as specified and directed.
S&F in replacement of battery 12 volts ,130AH with connecting leads of copper cable of suitable size including brass terminals etc complete.
S&F in replacement of battery 12 volts ,80AH with connecting leads of copper cable of suitable size including brass terminals etc complete.
M&L for replecement of existing unservicible Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make :-
DG Set 50 KVA
DG Set 62 to100 KVA.
Dismantaling taking out and opening of unserviceable 50 to 63 KVA DG Set engine repair/replacement of defective parts of piston,rings,valve,crank saft, connecting rod,pressure pipe line, injector, cylinder case, gasket if any repair to workshop and replacement of oil filter, fuel filter,replacing engine oil, air filter overhauling refixing same and testing commissioning at site complete all as specified and directed.
Dismantaling taking out and opening of unserviceable 50 to 63 KVA DG Set Alternator repair to defective parts of stator, rotor, excitor, armature rewinding and tit pit maintenance taking to workshop and refixing same and testing commissioning at site complete all as specified and directed.
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
S&F in repair capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.
S&F in repair capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor.
S&F in repair Double metalised paper and polypropylene technology(Mixed dielectric) capacitor cylindrical/box type for per KVAR power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR
M&L in replacement of existing unserviceable contector of current caring range 25 A to 40 Amp (AC-3 duty at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.
M&L in replacement of existing unserviceable contector of current caring range 9 A to 18 Amp (AC-3 duty at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage.
Supply and Repair/Replacement of MCB SP 6-32 Amps, 10 KA breaking capacity , 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement of MCB SPN 6-32 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement of MCB SPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed.
Supply and Repair/Replacement of MCB TPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed.
Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed.
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like lamp, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
S&F in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels .
Supply only the following spares suitable for LED street/Flood light fittings of
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/ Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 72 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable street light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed
S&F replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate, including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one.Make: Utkarsh Bansal/ National tubing Co/Jindal/Electrosteel. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
S&F in repair PVC insulated 3 core 1.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
Supply and fixing timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one .
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 25 Sqmm 3.5/4 core to 300 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 16 Sqmm 4 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
All as per Item No. 68 above but of size 10 Sqmm 4 core
All as per Item No. 68 above but of size 25 Sqmm 4 core
All as per Item No. 68 above but of size 35 Sqmm 3.5 core
All as per Item No. 68 above but of size 50 Sqmm 3.5 core
All as per Item No. 68 above but of size 70 Sqmm 3.5 core
All as per Item No. 68 above but of size 95 Sqmm 3.5 core
All as per Item No. 68 above but of size 120 Sqmm 3.5 core
All as per Item No. 68 above but of size 240 Sqmm 3.5 core
S&F PVC insulated copper conductor cable 10 Sq mm x 3 core for main Panel to main switch/ starter, MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge
S&F PVC insulated copper conductor cable 16 Sq mm x 3 core for main Panel to main switch/starter,MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge
S&F PVC insulated submersible copper conductor cable 10 Sq mm x 3 core for main Panel to main switch/starter/pump,MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
M&L for Horizontal Boring/ Cutting of Road/Foot Path for using through 40/80mm bore pipe for cable protection and finishing PCC after Boring/Cutting of road/Foot path, complete all as specified and as directed.
Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
Supply and Repair/Replacement for weather proof flat twin core 10 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
M&L for fault finding on LT cables of any size and any length with fault detective machine by thumbing method/other suitable find out method with suitable high voltage and all as and directed by Engineer-in-charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.
Supply and Repair/Replacement fixing Lug aluminium suitable cable size of 16 to 95 sqmm complete all as specified and directed Engineer-in-Charge.
Supply and Repair/Replacement fixing Lug aluminium suitable cable size of 120 to 400 sqmm complete all as specified and directed Engineer-in-Charge.
Supply and Repair/Replacement of industrial change over switch gear 200 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.
Supply and Repair/Replacement of industrial change over switch gear 100 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.
Supply and Repair/Replacement of industrial change over switch gear 250 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.
Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/ Replacement for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repair/Replacement for 125 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
Supply and Repeir/Replacement of panel mounted volt meter digital type 3 phase as per existing complete all as specied and directed
Repeir/Replacement of panel mounted Ammeter digital type 3 phase as per existing complete all as specied and directed
Taking out any damage of the already installed LT panel board doors/shutter and repair the broken doors by putting necessary nut,bolts,hinges, screw, welding etc and fix it again on the same panel board with two coats of synthetic enamel paint of existing colour complete upto 5 sqm complete all as specified and directed.
Taking out any damage of the already installed LT panel board doors/ shutter and repair the broken doors by putting necessary nut,bolts,hinges, welding etc and fix it again on the same panel board with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed.
Dismantling the defective LT UT cable 3.5/ 4 core from panel/DB/junction boxes, dismentling the cable gland if any, removing the pitted/burnt aluminium lugs and suplly and fixing of aluminium paim type lugs or lugs as per existing, crimping with suitable size crymping tool bit, refixing/ replacing cable gland, refixing the cable with suitable nut bolts & washers etc complete for the following size cable:- (Note:(i) one set of triple pole and neutral lugs will be measured as one job. (ii) The rate quoted deemed to be inclusive of insulation tape, nut bolts & washers etc complete. (iii)cable gland will be measured and paid separately. (iv) The rate quoted deemed to be inclusive the necessary earth work for removing loop of cable if any required complete all as directed
All as per Srl Item No. 106 above but for 25/35 sqmm
All as per Srl Item No. 106 above but for 50/70 sqmm
All as per Srl Item No. 106 above but for 70/95 sqmm
All as per Srl Item No. 106 above but for 120/150 sqmm
All as per Srl Item No. 106 above but for 240/300 sqmm
M&L for painting to steel tubular pole 9.00/11.0 metre long with one coat of red oxide on pole and two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge
M&L for painting to electric pole 9.00/11.0 metre long with two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips complete all as specified and directed by Engineer-in-Charge
M&L for numbering of pole no. Using stensils with two coats of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.
S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge
Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge
Supply and Repair/Replacement of decorative gate light MUSHROOM (PRISMATIC) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge
Supply and Repair/Replacement of decorative gate light Lexo (Prismatic) made up of high grade unbreakeble polycorbonate material suitable B22 Base and upto 60 mm pole dia with 10 watt LED lamp coplete all as specified and directed by Engineer-in-Charge
Supply and Repair/Replacement of new generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed by Engineer - in - Charge.
Supply and Repair/Replacement of Building street light fitting Endura pearl 25W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post and all as required and directed
Cleaning/desludging of raw sewage in under ground collection sump well up to the depth 7 mtr installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portabale non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove raw material and transport it to outside cantonment area for disposal at low lying area up to the distance of 10 Kms at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interior surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint.
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 40 to 100 Amps complete including control wiring thimbles etc complete all as directed.
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 250 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 200 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 160 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 160 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 100 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
Dismantling unserviceable valves and Supply, fixing,testing and commissioning of butterfly valves incl cutting, welding etc complete all as directed.
All as per Item No.127 above but for 50 mm bore
All as per Item No.127 above but for 80 mm bore
M&L for dismantling the defective induction motor of any make & capacity 3 HP to 5 HP , any duty or any class of insulation from the bed, duly coupled with pump/ motor transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.
M&L for dismantling the defective induction motor of any make & capacity 7.5 HP to 10 HP , any duty or any class of insulation from the bed, duly coupled with pump/ motor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.
M&L for dismantling the defective sewage non clog submersible motor of any make & capacity 10 Hp to 15 HP from sewage well/sump, any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts and refixing the same as sewage sump complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled,dismandling and refixing completely and quoted rate is inclusive for the same.
Repair/Replacement of Fe 410-W (Gde E- 250) for Room/Power Room Duct Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy racket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc
Supply only (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) with chlorine content 65 to 70 % , packing in 45 kg drum complete all as specified and directed by Engr-in-Charge.
Supply only stable bleaching power (SBP)(Calcium hypochloride)Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc all as per IS.
M&L for Galvanised iron round bracket made out of 40mm dia GI tubing including making provision for fixing of 04/06 no flood light on 11 mtr steel tubular pole ad fixing and connecting up of LED lights (LED lights shall be measured seperately under respective items of sch ) complete all as specified and directed. Note: The inner diameter of ring shall not be less than 1.0 meter
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof/fall ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S SHRI RAM BUILDERS
Commercial Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .