Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹3.7 Cr+₹10.5 L (2.94%)Rejected-Finance | ₹3.7 Cr+₹10.5 L (2.94%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.7 Cr+₹18.6 L (5.24%)Rejected-Finance | ₹3.7 Cr+₹18.6 L (5.24%) | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Oinam Anil Singh L2 | M/s LL Enterprises L1 | HAOBIJAM JOY SINGH L3 |
|---|---|---|---|---|---|---|
| 1.00(1) QUARTER GUARD | ||||||
| 2.00SH : EARTH WORK | ||||||
| 3.00 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil . | 301.11 | m3 | 540 ₹1,62,599.4 | 520 ₹1,56,577.2 Lowest | 550 ₹1,65,610.5 |
| 4.00 | (b) Lift above 1.5 m upto 3.0 m | 51.75 | m3 | 650 ₹33,637.5 | 620 ₹32,085 Lowest | 660 ₹34,155 |
| 5.00 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth , consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m. | 117.62 | m3 | 230 ₹27,052.6 | 220 ₹25,876.4 Lowest | 235 ₹27,640.7 |
| 6.00 | Supplying and filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 km | 250.48 | m3 | 1,270 ₹3,18,109.6 | 1,250 ₹3,13,100 Lowest | 1,290 ₹3,23,119.2 |
| 7.00 | Providing laying & compacting granular base/sub-base with naturally occuring Sand Gravel Material free from organic or other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness) | 14.43 | m3 | 2,530 ₹36,507.9 | 2,500 ₹36,075 Lowest | 2,570 ₹37,085.1 |
| 8.00SH: CONCRETE WORKS | ||||||
| 9.00 | P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:5:10 (1 cem :5 Kanhaighat coarse sand:: 10 graded stone aggrt. 40mm nominal size). | 89.26 | m3 | 10,980 ₹9,80,074.8 | 10,700 ₹9,55,082 Lowest | 11,140 ₹9,94,356.4 |
| 10.00SH : R.C.C. WORKS | ||||||
Tender Value
₹3.0 Cr
EMD Value
₹6.1 L
Closing Date
25 Sept 2025, 1:00 pmClosed
Executive Engineer-I
MPHC Office Complex
Construction of Quarter Guard and Store block at 69 Bn.HQr. CRPF Mantripukhri, for the Financial Year, 2024-2025
2025_MPHCL_2937_1
01/EE-I/MPHC/2025-26
Open Tender
Civil Works
Works
365 days
As per tender documents
As per tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd.
₹6.1 L
3 Dec 2025
12 Sept 2025
25 Sept 2025
12 Sept 2025
25 Sept 2025
13 Sept 2025
13 Sept 2025 - 24 Sept 2025
Amount
(1) QUARTER GUARD
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil .
(b) Lift above 1.5 m upto 3.0 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth , consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 km
Providing laying & compacting granular base/sub-base with naturally occuring Sand Gravel Material free from organic or other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)
SH: CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:5:10 (1 cem :5 Kanhaighat coarse sand:: 10 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand: : 3 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degreedings,balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand: : 3 graded stone aggrt. 20mm nominal size).
Reinforced cement concrete work in vertical and horizontal and fins individually or forming box louvers, facias and eaves board up above plinth level up to floor five level excluding the cost of centering, shutering, finishing and reinforcement with 1:1.5:3 (1 cem:1.5 Kanhaighat c/sand :3 graded stone aggregate 20mm nominal size)
SH: FORM WORKS
Centering & shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. for mass concrete.
( b ) Lintels, beams,plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick.
( c )Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick.
(d) Columns, pillars, Piers, Abutments, Posts and Struts.
(e) Stairs, ( excluding landing) except spiral-staircases.
(f) Edges of slab and breaks in floors and walls.(i) Under 20 cm wide.
(g) vertical and horizontal and fins individually or forming box louvers, facias and eaves board up above
Reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete. (b) Thermo-Mechanical-Treated bars.
SH: BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Brick work with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local 1st class) in cement motar 1:4 (1 cem:4 Kanhaighat coarse sand ) in superstructure (a) Above plinth up to 1st floor level)
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fasterner of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(i) Local best quality Teak
Providing and fixing penelled or panelled and glazed shutters fo doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, ecluding panelling which will be paid for separate(Area of opening for ly, all complete as per direction of Engineer-in- charge. : (i) Local best quality Teak (i) 35 mm thik
Providing and fixing penelling or panelling and glazed shutters fo doors, windows and clerestory windows (Area of opening for panel insets excluding position inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thik : (i) Local best quality Teak
P/F glazed shutters for doors windows and clerestory windows using 4mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws a)Local best quality Teak wood.
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing & fixing M.S. grills of required pattern in frames of windows etc with M.S. flats, square or round bars etc. including priming coat with approved sleel primer all complete.(ii) Fixed to openings/wooden frames with rawl plugs screws etc.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc. complete .(i) 300X16 mm
Providing and fixing aluminium tower bolts , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with screws etc. complete .(i) 300X10 mm
(ii) 250X10 mm
Providing and fixing aluminium handles , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with screws etc. complete .(i) 125 mm
SH: STEEL WORKS
Steel work welded in built up sections / framed work in cutting cutting , hoisting, fixing in position and applyying a priming coat of approed steel primier using steel etc. as required (i) In grating , frames, guard ar, railing, brackets, gates and similar works.
P/F 20mm dia.Vertical bar lock up door wuth chaukhat frames 60X60X5mm styles and rails of 50x50x5mm bracing and holdfast etc. of 40x40x 6mm with locking arrangement hook and handles with sliding bolts including the cost of priming coat etc. complete.
P/F 2mm thick M.S.Sheet door shutters and gate shutter with chaukhat frame of 60x60x5mm , door frame 50x50x5mm with locking arrangement, hooks and handles bracing and lodging, hold fast etc. of 40x40x5mm with locking arrangement, hooks and handles with sliding bolts and including the cost of priming coat.
P/F with M.S. 20mm diameter guard bar and wire mesh steel windows and ventilators with frame of 40X40X6mm angle iron , all necessary fittings complete, including applying apriming coat of approved steel primer.
Cement concrete flooring 1:2:4 (1 Cement: 2 Kanhaighat coarse sand:4 stone aggregate 20 mm & down gauge) finished with a floating coat of neat cement. Slurry, but excluding the cost of noising of steps etc. (i) 40 mm thick with 20mm nominal size stone aggregate.
Cement plaster skirting (upto 30cm height) with cement mortar 1:3 (1 cement:3 kanaighat c/ sand ) finished with a floating coat 0f neat cement (a) 18 mm thick
SH: FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster on rough side of single or half brick wall of mix. 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster on rough side of single or half brick wall of mix. 1:3 (1 cement : 3 coarse sand:)finished with a floating coat of neat cement on the roughside of single or half brick wall.
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface (a) water thinable cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plasterd wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade new work (two or more coats applied @ 1.67litr/ 10 sqm over and including base coat of water proofing cement paint applied @ 2.2kg/ 10sqm).
Distemperring with oil bound washable distemper of approved brand and manufacture to give an even shade Neww work ( two or more coats) over and including prriming coat with cement primer
Applying priming coat with ready mixed pink or Gray primer of approved brand and manufacture on wood work (hard and soft wood).
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of appd. quality in all shades on new work to give an even shade.
Supplying and Applying Dr. Fixit Primeseal ( after making dilution with water in the ratio 2:1 (2 Primeseal : 1 Water) on new roof at 1 Litre per 9.3 sqm.after cleaning the surface using wire brush or appropriate tools (surface to be washed off with water) and allow drying fo 2-3 hours before applying Dr. Fixit Newcoat over this coat as per direction of the Engineer-in-Charge.
Supplying and Applying Dr. Fixit Newcoat on Primeseal roof surface in three different coats at 1 Litre per1.95 sqm.per coat, laying fibre mesh with adhesive primer (consuming 20 litres for 80 sheets of 3x10m fibre mesh) after 1st coat of Newcoat. 2nd coat of Newcoat should be applied immediately after laying of fibre mesh. 3rd coat of Dr. Fixit Newcoat should be applied after allowing drying of the 2nd coat for 6 to 8 hrs. Each coat should be applied in perpendicular direction to the underlying layer. The entire process should be carried out under strict supervision and direction of the Engineer-in-Charge.
Providing and fixing UPVC soil, waste, rain water and vent , pipes including all requisite fittings , joining of pipes & fittings with solvents cement, trenching , refilling & testing of joins complete as per direction of Engineer in charge (i) 110mm dia.
Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50X50X50mm hard hood plugs ,screwed with M.S. Screws of required length including cutting brick work and fitting in cement motar 1:4 (1 cem: Kanhaighat c/sand) and making good the walls etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 gms.
Making plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggrt. of 20 mm nominal size)over 75 mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3c/sand) with a floating coat of neat cement inside & outside as per standard design.
(2) STORE BLOCK
SH : -(A) GROUND FLOOR
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil .
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth , consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 km
SH : CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:5:10 (1 cem :5 Kanhaighat coarse sand:: 10 graded stone aggrt. 40mm nominal size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand: : 3 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degreedings,balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand: : 3 graded stone aggrt. 20mm nominal size).
SH : FORM WORKS
Centering & shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. for mass concrete.
( b ) Lintels, beams,plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick.
( c )Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick.
(d) Columns, pillars, Piers, Abutments, Posts and Struts.
(e) Stairs, ( excluding landing) except spiral-staircases.
(f) Edges of slab and breaks in floors and walls.(i) Under 20 cm wide.
Reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete. (b) Thermo-Mechanical-Treated bars.
SH: BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local 1st class) in cement motar 1:4 (1 cem:4 Kanhaighat coarse sand ) in superstructure (a) Above plinth up to 1st floor level)
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fasterner of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(i) Local best quality Teak
Providing and fixing penelled or panelled and glazed shutters fo doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, ecluding panelling which will be paid for separate(Area of opening for ly, all complete as per direction of Engineer-in- charge. : (i) Local best quality Teak (i) 35 mm thik
Providing and fixing penelling or panelling and glazed shutters fo doors, windows and clerestory windows (Area of opening for panel insets excluding position inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thik : (i) Local best quality Teak
P/F glazed shutters for doors windows and clerestory windows using 4mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws a)Local best quality Teak wood.
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc. complete .(i) 300X16 mm
Providing and fixing aluminium tower bolts , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with screws etc. complete .(i) 300X10 mm
(ii) 200X10 mm
Providing and fixing aluminium handles , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with screws etc. complete .(i) 125 mm
SH: STEEL WORKS
Steel work welded in built up sections / framed work in cutting cutting , hoisting, fixing in position and applyying a priming coat of approed steel primier using steel etc. as required (i) In grating , frames, guard ar, railing, brackets, gates and similar works.
P/F with M.S. 20mm diameter guard bar and wire mesh steel windows and ventilators with frame of 40X40X6mm angle iron , all necessary fittings complete, including applying apriming coat of approved steel primer.
Cement concrete flooring 1:2:4 (1 Cement: 2 Kanhaighat coarse sand:4 stone aggregate 20 mm & down gauge) finished with a floating coat of neat cement. Slurry, but excluding the cost of noising of steps etc. (i) 40 mm thick with 20mm nominal size stone aggregate.
Cement plaster skirting (upto 30cm height) with cement mortar 1:3 (1 cement:3 kanaighat c/ sand ) finished with a floating coat 0f neat cement (a) 18 mm thick
SH: FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster on rough side of single or half brick wall of mix. 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface (a) water thinable cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plasterd wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade new work (two or more coats applied @ 1.67litr/ 10 sqm over and including base coat of water proofing cement paint applied @ 2.2kg/ 10sqm).
Distemperring with oil bound washable distemper of approved brand and manufacture to give an even shade Neww work ( two or more coats) over and including prriming coat with cement primer
Applying priming coat with ready mixed pink or Gray primer of approved brand and manufacture on wood work (hard and soft wood).
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of appd. quality in all shades on new work to give an even shade.
Making plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggrt. of 20 mm nominal size)over 75 mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH : -(B) FIRST FLOOR
SH: R.C.C WORKS
RCC work in in walls (any thickness), including attached pilasters, buttresses, plinth and string ourses,fillets,columns, pillars, piers,abutment, posts and struts etc. upto floor five level excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand: : 3 graded stone aggrt. 20mm nominal size).
RCC work in beams, suspended floors, roofs having slope upto 15 degreedings,balconies,shelves,chajjas, lintels,bands,plain window sill,staircases and spiral staircase upto floor five level but excluding the cost of centering, shuttering ,finishing and reinforcement (a) 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand: : 3 graded stone aggrt. 20mm nominal size).
SH: FORM WORKS
Centering & shuttering including strutting, propping etc. and removal of form for:
( b ) Lintels, beams,plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick.
(c ) Columns, pillars, Piers, Abutments, Posts and Struts.
Reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete. (b) Thermo-Mechanical-Treated bars.
SH: BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Half brick masonry 2nd class (local 1st class) in cement motar 1:4 (1 cem:4 Kanhaighat coarse sand ) in superstructure (a) Above plinth up to 1st floor level)
SH: WOOD WORKS
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fasterner of required dia and length (hold fast lugs or dash fastener shall be paid for separately :(i) Local best quality Teak
Providing and fixing penelled or panelled and glazed shutters fo doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, ecluding panelling which will be paid for separate(Area of opening for ly, all complete as per direction of Engineer-in- charge. : (i) Local best quality Teak (i) 35 mm thik
Providing and fixing penelling or panelling and glazed shutters fo doors, windows and clerestory windows (Area of opening for panel insets excluding position inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thik : (i) Local best quality Teak
P/F glazed shutters for doors windows and clerestory windows using 4mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws a)Local best quality Teak wood.
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing & fixing M.S. grills of required pattern in frames of windows etc with M.S. flats, square or round bars etc. including priming coat with approved sleel primer all complete.(ii) Fixed to openings/wooden frames with rawl plugs screws etc.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc. complete .(i) 300X16 mm
Providing and fixing aluminium tower bolts , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with screws etc. complete .(i) 300X10 mm
(ii) 200X10 mm
Providing and fixing aluminium handles , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with screws etc. complete i) 125 mm
P/F with M.S. 20mm diameter guard bar and wire mesh steel windows and ventilators with frame of 40X40X6mm angle iron , all necessary fittings complete, including applying apriming coat of approved steel primer.
SH ;ROOFING
Steel work in built up RHS/SHS (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(i) Hot finished welded type tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams pe sqm as pe IS; 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge . The sheet shall be fixed using self drilling/ self tapping screws of (5.5X55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (i) (Precoated galvanised iron profile sheets 0.50mm thick,
Providing and fixing precoated galvanised steel sheet roofing accessories, zinc coating 120gms as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using sel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams pe sqm as pe IS; 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coate 15-18 microns using self drilling/ self tapping screws or with polymer coatedJ or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete: (a) Ridges plain(500-600mm) (i) Precoated galvanised iron profile sheets 0..50 mmthick.
P/F 1mm thick M.S.Sheet eave board with ISA 25x25x4mm and flat 25x4mm with primer and painting complete as per direction of Engineer-in- Charge.
Cement concrete flooring 1:2:4 (1 Cement: 2 Kanhaighat coarse sand:4 stone aggregate 20 mm & down gauge) finished with a floating coat of neat cement. Slurry, but excluding the cost of noising of steps etc. (i) 40 mm thick with 20mm nominal size stone aggregate.
Cement plaster skirting (upto 30cm height) with cement mortar 1:3 (1 cement:3 kanaighat c/ sand ) finished with a floating coat 0f neat cement (a) 18 mm thick
SH: FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand:).
15mm cement plaster on rough side of single or half brick wall of mix. 1:4 (1 cement : 4 Kanhaighat coarse sand:).
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface (a) water thinable cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plasterd wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade new work (two or more coats applied @ 1.67litr/ 10 sqm over and including base coat of water proofing cement paint applied @ 2.2kg/ 10sqm).
Distemperring with oil bound washable distemper of approved brand and manufacture to give an even shade Neww work ( two or more coats) over and including prriming coat with cement primer
Applying priming coat with ready mixed pink or Gray primer of approved brand and manufacture on wood work (hard and soft wood).
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of appd. quality in all shades on new work to give an even shade.
Oinam Anil Singh (BID ID -9952)
HAOBIJAM JOY SINGH (BID ID -9953)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .