Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.4 LAccepted-AOC | ₹29.4 L Quoted ₹29.8 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹31.9 LRejected-Finance | ₹31.9 L | L-2 | Rejected-Finance L-2 |
| 3 | L-3₹35.7 LRejected-Finance | ₹35.7 L | L-3 | Rejected-Finance L-3 |
| 4 | L-4₹36.4 LRejected-Finance | ₹36.4 L | L-4 | Rejected-Finance L-4 |
| 5 | L-5₹38.9 LRejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | ₹38.9 L | L-5 | Rejected-Finance L-5 |
| Sl No | Description | Qty | Unit | M/S Yamin L1 | H.B. Traders L4 | Singh Associates L5 | PRAHLAD NARAIN KOLI L2 | SAGAR ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed. | 26.4 | Cum | 100 ₹2,640 | 100 ₹2,640 | 300 ₹7,920 | 150 ₹3,960 | 99 ₹2,613.60 |
| 2.00 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. | 16.8 | Cum | 3,000 ₹50,400 | 3,800 ₹63,840 | 3,000 ₹50,400 | 3,000 ₹50,400 | 2,500 ₹42,000 |
| 3.00 | All as per item No 02 above but except bricks. | 7.2 | Cum | 1,400 ₹10,080 | 1,200 ₹8,640 | 1,500 ₹10,800 | 600 ₹4,320 | 2,200 ₹15,840 |
| 4.00 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as directed. | 40 | Sqm | 450 ₹18,000 | 1,200 ₹48,000 | 650 ₹26,000 | 550 ₹22,000 | 350 ₹14,000 |
| 5.00 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed | 3,815 | Sqm | 10 ₹38,150 | 10 ₹38,150 | 5 ₹19,075 | 15 ₹57,225 | 5 ₹19,075 |
| 6.00 | M&L for rendering 15 mm thick in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed. | 1,150 | Sqm | 140 ₹1.6 L | 160 ₹1.8 L | 130 ₹1.5 L | 160 ₹1.8 L | 80 ₹92,000 |
| 7.00 | M&L for rendering 15mm thick in CM 1:4 on brick work or concrete surface finish even and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. | 1,465 | Sqm | 142 ₹2.1 L | 160 ₹2.3 L | 170 ₹2.5 L | 165 ₹2.4 L | 80 ₹1.2 L |
| 8.00 | M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. . | 745 | Sqm | 140 ₹1.0 L | 160 ₹1.2 L | 130 ₹96,850 | 160 ₹1.2 L | 80 ₹59,600 |
| 9.00 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. | 1,175 | Sqm | 40 ₹47,000 | 22 ₹25,850 | 50 ₹58,750 | 40 ₹47,000 | 30 ₹35,250 |
| 10.00 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. | 610 | Sqm | 30 ₹18,300 | 22 ₹13,420 | 50 ₹30,500 | 40 ₹24,400 | 30 ₹18,300 |
Updated dates
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
3 Dec 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
PERIODICAL SERVICES, REPAIR TO COMPOUND WALL, FOOTPATH, LEAKAGE, SEEPAGE, OVERHEAD TANKS, FALSE CEILING, CLEANING/REPAIR OF SEWAGE LINE, MANHOLE, SEPTIC TANK, SOAKAGE WELL ETC AND CONNECTED WORKS AT AF STN 3 WING UNDER AOR OF GE (AF) FARIDABAD
2025_MES_739432_1
GE (FBD)/AF-T-67/2025-2026
Open Tender
Civil Works
180 days
Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹98,000
Yes
19 Feb 2026
12 Nov 2025
5 Dec 2025
12 Nov 2025
3 Dec 2025
19 Nov 2025
Amount
Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
All as per item No 02 above but except bricks.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as directed.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for rendering 15 mm thick in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick work or concrete surface finish even and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. .
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed.
M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white/tinted over a coat of appropirate primer over including a layer 2 mm wall care putty to achieve desired smoothness and eveness complete by hand roller complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surface of walls & Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, filling cracks with wall care putty etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment on walls/ roof projections including facial, cornices etc by scrapping with mechanical sander/Paint remover machine (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7"/9" to make free from dust, loose paint etc by skilled labour complete all as specified and directed.
M&L for applying two coats of oil bound distemper (OBD) over a coat of appropirate primer over and including a layer 2mm thick acrylic wall putty to achieve desired smoothness and eveness complete all as specified & directed by Engineer-in-Charge.
M&L for applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre / 10 sqm including a layer 2mm thick acrylic wall putty to achieve desired smoothness and eveness complete all as specified & directed by Engineer-in-Charge.
M&L for writing letters or figures (Block. Roman, Italic or Indian) not exceding 30 cm high complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
M&L for securing of old glass of any description in existing metal frame glazed with putty / beads including removing loose or decayed putty, beads painting / oiling one coat on rebates, groves reputting and painting / oiling puttied surface to match existing work (New length of frame reputtied shall be measured) complete all as specified and directed by Engineer-in-charge.
S&F in repair 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed.
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care putty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed. Note : Colour and make as approved by Engr-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper complete all as specified and directed.
M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces and obtain smooth finish using sand paper complete all as specified and directed.
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of white wash on surface of ceiling complete all as spcified and directed.
Demolition of cement concrete unreinforced in of any desciption and in any position not otherwise specifically provided for (sunken floor) and concrete debris and rubbishoff to a distance n exc 100m as directed by the EIC.
M&L, for rendering 10mm thick in CM 1:3 with and incl WPC as per manufacturer instruction in sunken slab complete all as specified and directed.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed.
M&L, cement concrete 1:7:12 F-2 (40 mm graded stone aggregate ) in lean concrete complete all as specified and directed.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed.
M& L for premium quaility Glazed ceramic jointless light/coloured group of size 350mmx450mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as specified and directed. Note : shade & design as approved by EIC/GE.
M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed.
S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as specified and directed.
S&F of PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern in repairs complete all as specified and directed.
S&F for Vitreous China wash basin (Pedestal pattern), White, flat back, size 550x400 mm incl brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper with and including PVC collapsible waste pipe of suitable length, fixed in repairs complete all as specified and directed.
S & F in repair vitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, (Exclusive of fixing supply pipe to flushing cistern, trap & waste pipe complete all as specified and directed.
Taking down existing roof treatment of any description and any type complete all as specified and directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, incl Brushing neat cement slurry with 3.0kg of cement per sq. metreetc all as specified and directed.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3.50 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed.
M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified and directed.
M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate in roof padding and surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Making benching with PCC (1:2:4) type B0 using 12.5mm graded stone aggregate incl. WPC along side wall adjoining to roof in concave shape complete all as specified.
Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, completer all as specified and directed.
S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting ,dismantling existing water tank complete all as specified and directed.
S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting , tank cover dismantling existing water tank complete all as specified and directed.
S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size " Tank cleaning on dt _______ " complete all as specified and directed. (a) Tank Capacit exc 250 Ltr but n exc 500 Ltr.
S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size " Tank cleaning on dt _______ " complete all as specified and directed. (a) Tank Capacit exc 500 Ltr but n exc 1000 Ltr.
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required all as directed and specified.
S&F GI tubing 15 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Fixing only in repair steel tubing and connection 15 mm dia bore to wall and laid in floors.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed..
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Fixing only in repair steel tubing and connection 20 mm dia bore to wall and laid in floors complete all as specified and directed.
S&F in repair Gun-metal globe or gate valves of 20mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. .
Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed.
S & F for plain gypsum board panel 10mm thick on ceiling with and incl necessary Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and the weight of the board shall be not less than 7 kg per sqm incl dismantling of walls and ceiling board any type complete all as specified and directed.
M&L for WPC primium quality panelling 9 to 10 mm thick on ceilling including with necessary frame work in POP Design and any colour approved by engr-in-charge, inclusive of fixing on to wall/ceiling incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed
M&L in repair for WPC primium quality wall panelling 9 to 10mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed
Dismantling of AC/GI sheet (corrugated, semi corrugated etc) of any thickness incl ridges hips valleys as in roof coverings complete all as specified and directed.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as directed and specified.
S& F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specifed and directed.
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A all as specified and directed.
All as per item No 67 above but fixing only.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed.
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care putty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. Note : Colour and make as approved by Engr-in-Charge.
M & L for preparation of old stone, concrete surfaces of any description over 10 CM width or girth and applying one coat of plastic emulsion paint (Weather Coat) on old footpath/colour tiles/ kerb stone etc (colour and pattren as per approved by EIC ) complete all as specified and directed.
M & L for precast cement concrete louveres and jallies, 25mm thick, type B0 1:2:4 (12.5 mm graded stone aggregate), set in CM 1:4, including all mouldings complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris v
M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection / path/ any paved area complete all as specified and directed.
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 60 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment,(M-35) grade any colours as approved by EIC /GE complete all as specified and directed
Labour only for 60 mm thick machine cut precast concrete inter locking paver block (except tile), (M-35) grade any colours as approved by EIC /GE complete all as specified and directed
M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any colours as approved by EIC /GE complete all as specified and directed
Labour only for 80 mm thick machine cut precast concrete inter locking paver block (except tile), (M-40) grade any colours as approved by EIC /GE complete all as specified and directed
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified.
M & L for machine pressed chequered cement concrete tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over & including 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as spd and directed.
M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement, rubbish off the primises complete all as specified and directed.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' in on concrete slab 100mm all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete inposition to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level n. exc 1.50 m above the starting point complete all as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed.
Labour only for 60 mm thick machine cut precast concrete inter locking paver block except tile ,(M-35) grade any clours as approved by EIC /GE complete all as specified and directed
Cleaning /removal of blockage 150 mm bore SWG pipes of depth not exc 1.50 mtr with mechnical process incl removing RCC man hole covers and refixing the same as per existing complete all as specified and directed.
Cleaning /removal of blockage 150 mm bore SWG pipes of depth exc 1.50 mtr but not exc 3.00 mtr with mechnical process incl removing RCC man hole covers and refixing the same as per existing complete all specified
Dewatering/desilting of existing manholes of any size depth and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system or using suction pump where ever required up to any depth )and incl removing RCC manhole Covers and refixing the same after making the manhole fully functional, complete all as specified and directed.
Dewatering/desilting for the septic tank of any capacity exc1.50 m and n.exc 4.5 m deep solid/semi-solid matter of silt residue both organic or inorganic in nature ( mechanical system or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as specified and directed. Note for Item : The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft or loose soil for shafts, wells,drains, manholes etc n exc 10Sqm on plan for sewage line & foundation etc all as specified and directed by Engr-in-charge.
All as per item No 97 but exceeding 1.5 M depth and not exceeding 3 M for foundation, etc, and getting out in Soft/ Loose soil.
All as per item No 97 but exceeding 3.0 M depth and not exceeding 4.50M for foundation, etc, and getting out in Soft/ Loose soil.
Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land all as directed.
Demoltion and breaking up existing sewag(SWR/ AC pipes and the like, 150mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m all as directed by Engr-in-charge.
Demoltion and breaking up existing sewage (SGSW / AC pipes and the like, 200mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m all as directed by Engr-in-charge.
S&F 110 mm PVC (SWR ) , pipes single socketd , in any length with rubber ring joints , laid in trenches or in floor complete all as specified & directed by Engr-in-Charge.
S & F RCC Class NP 3, 150 mm bore pipes laid and jointed complete with collars complete all as specified and directed.
S & F RCC Class NP 3, 200 mm bore pipes laid and jointed complete with collars complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore complete all as specified and directed.
S & F in repair for precast factory made reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of 60mm thick (size of the cover will be itimated by the Engineer-in-Charge) complete all as specified and directed.
S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover 100 mm thick rectangle in shape upto 01 sqm area each with hole for drain complete all as specified and directed.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as in copings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating , complete all as specified and directed. (Rates include for use of formwork)
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 150mm dia pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 200mm dia pipe complete all as specified and directed.
M&L for salt glazed stoneware gully trap, square or round moulded type 'P', 150x150mm size complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 20 mm graded stone aggregate) as in surface channels, drains and bed of manhole complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M & L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, and mass concrete complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specified and directed.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specifed and dirtected.
S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected.
S&F 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specifed and dirtected.
S&F for 100mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specifed and dirtected.
S&F for 75mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specifed and dirtected.
S& F for 75 Cast Iron Cowl complete all as specifed and dirtected.
S& F for 100 Cast Iron Cowl complete all as specifed and dirtected.
S&F for 75mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specifed and dirtected.
S&F for 100mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specifed and dirtected.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed.
All as per ser item No 133 above but laid in trench or in floor
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed. .
S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed. .
S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. .
S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. .
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed.
S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed. .
S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed.
Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed.
(Note for serial item No. __________) The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorized applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall submit the documents “Memoradum of Understanding” (MoU), between tenderer, manufacturer's of paints and their authorised applicator at the time of bidding with atleast one of the manufacturers mentioned in the contract documents. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures as per site requirement. (d) Removing of nails, making good holes, cracks etc as per site requirement. (e) Work in patches and in narrow / widths, bands, cornices, plasters etc and cutting in edge of line where necessary. (f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (g) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Removing and existing furniture for painting work and replacing the same post painting work, movable cupboard, chicks, blinds etc.
(j) Sample patch of 10 Sqm be prepared considering all the items of periodicals and shall be got approved from GE prior to carrying out further subject work. The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (k) GUARANTEE OF PERIODICAL SERVICES: Periodical services against item No ___________ of BOQ using mechanized equipment’s only executed under this contract are under the guarantee of contractor for 05 (Five) Years after the certified physical completion of work. Contractor is fully liable under this guarantee to rectify and redo all defective work intimated to him during this period including all type of materials and labour to the specifications catered for in the contract. In case contractor fails to rectify the defective work, Accepting officer shall get the rectification done as necessary at the risk and cost of contractor and recover the cost in full from the contractor. If the contractor consider that any additional treatment is required over and above that specified here in before in Schedule ‘A’, the same shall be carried out by the contractor without any extra cost to the Government.
PRAHLAD NARAIN KOLI (BID ID -3478713)
SAGAR ENTERPRISES (BID ID -3485819)
H.B. Traders (BID ID -3484339)
Singh Associates (BID ID -3488713)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_827964.xls
BOQ • 0.68 MB
Tenderdocu67.pdf
Tender Documents • 1.06 MB
Download all tender documents and submit your bid