| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.6 LAccepted-AOC 0 NERTHUA RAEBARELI UTTAR PRADESH 229103 | RAE BARELI | UTTAR PRADESH | 229103 | L1 | Accepted-AOC Accepted due to lowest | |
| 2 | L2₹51.9 L+₹5,386.40 (0.10%)Rejected-Finance AT POST ARANGAON MEHERABAD TAL DIST AHMEDNAGAR PIN 414006 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414006 | L2 | Rejected-Finance Not lowest |
Tender Value
₹51.9 L
EMD Value
₹1.0 L
Closing Date
1 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Vikas Kesarwani
HQ CWE Airforce Lohegaon
ADDITION, ALTERATION, IMPROVEMENT TO MAIN GATE (TATA GATE) AT 9 BRD AT AIRFORCE STATION PUNE
2022_MES_572245_1
81865/E8
Open Tender
Civil Works
Item Rate
180 days
GE Airforce Lohegaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE Airforce Lohegaon
₹1.0 L
Yes
30 Mar 2023
30 Dec 2022
8 Feb 2023
30 Dec 2022
1 Feb 2023
20 Jan 2023
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations, etc and laying of cable or for shafts, wells, manholes etc and getting out in soft /loose soil complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser Item No.1.00 above but soft disintegrated rock complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser Item No.1.00 above but exc 1.5m but not exc 3m in depth as in soft disintegrated rock complete all as specified and as directed by Engr-in- Charge.
Surface excavation not.exc. 30 cm deep and averaging 15cm deep and getting out in in any type of soil complete all as specified and as directed by Engr-in- Charge.
M&L for Cement concrete 100 mm thick, type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and as directed by Engr-in- Charge.
M&L for machine pressed precast rubberised glossy concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS15658-2006 of 60mm thickness , M-35 Grade laid over 50 mm thick sand cushioning to interlocking paver block complete all as specified and as directed by Engr-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
Removing excavated excavated soil/ material exceeding not exceeding and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in- Charge.
Removing excavated excavated soil/ material exceeding 50mtr but not.exc 250 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in- Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm in soft disintegrated rock obtained from excavation complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete 1:4:8, type D2, using (40mm aggregate) in foundations, plinth beams filling and mass concrete complete all as specified and directed by Engineer in charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; and mass concrete complete all as specified and directed by Engineer in charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer in charge.
M & L for MS TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders or securing with clips etc complete all as specified and directed by Engineer in charge.
S&F Rolled sections as in coloums, vertical posts etc. fixed with angle cleats or other connecting plates Fe 290 (Gde E-165) complete all as specified and directed by Engineer in charge.
S & F rolled mild steel as in tubular trusses (framed) purlins, angle, beam, tee, channel including distance piece, cleats etc , grade Fe - 410W (gde E 250 quality B) with and including necessary cutting, bending, drilling holes, welding rebates etc complete all as specified and directed by Engineer in charge.
M&L 20 mm Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, upto 30cm long complete all as specified and directed by Engineer in charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting (PPGL) 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws etc complete all as specified and directed by Engineer in charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheeting (PPGL) 0.50mm thick of any colour having tensile strength 550 Mpa as in ridge, hip, valley gutters, drip and straight flashing fixed with self tapping screws etc complete all as specified and directed by Engineer in charge.
Material and labour for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and directed by Engr-in- Charge.
M&L for preparation of old steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed by Engr-in- Charge.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm of type C1 1:3:6 using 20mm graded aggregate in width and setting in mortar 1:6 , complete all as specified and as directed by Engr-in- Charge.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and as directed by Engr-in- Charge..
M&L for providing, cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in coping, kerbs or mud stops, rounded or chamfered on edges etc ccomplete all as specified and as directed by Engr-in- Charge.
Material and labour for 10 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair complete all as specified and as directed by Engr-in- Charge.
Providing precast cement concrete in cover slabs (for man holes etc.)window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings., but in landings, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces Set in cement mortar 1:4 Type B1 1:2:4 (20mm graded aggregate) complete all as specified and as directed by Engr-in- Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed by Engr-in- Charge.
M&L for Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc conforming to Fe.290.Gde-E-165. complete all as specified and as directed by Engr-in- Charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms etc and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engr-in- Charge.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and as directed by Engr-in- Charge.
M& L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick (Horizontal or sloping) rough finished flat surfaces of concrete complete all as specified and as directed by Engr-in- Charge.
M&L for Reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engr-in- Charge.
M&L for Reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engr-in- Charge.
M&L for Reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) Columns, pillars, piers, posts and struts complete all as specified and as directed by Engr-in- Charge.
M&L for Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses of Reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) complete all as specified and as directed by Engr-in- Charge.
M & L for Formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter as in rough finished surfaces. complete all as specified and as directed by Engr-in- Charge.
M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engr-in- Charge.
M& L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays etween floors and beams, etc. complete all as specified and as directed by Engr-in- Charge.
Demolition of brickwork or stone/ boulder masonry, laid dry but built in cement mortar for ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and as directed by Engr-in- Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-in- Charge.
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete all as specified and as directed by Engr-in- Charge.
Supply only Liquid water proofing compound complete all as specified and as directed by Engr-in- Charge.
M&L for rendering 5mm thick in CM 1:3 on ceiling fair faces of block masonry or concrete surfaces .complete all as specified and as directed by Engr-in- Charge.
M & L for preparation of newly plastered surfaces and applying two coats of oil bond distemper over a coat of chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and as directed by Engr-in- Charge.
All as per item No. 45 above but on ceiling complete all as specified and as directed by Engr-in- Charge.
Material & Labour for applying two coats of premium acrylic emulsion paint over a coat of primer including wall care putty on new surfaces and make surface smooth and free from undulation complete all as specified and as directed by Engr-in- Charge.
Complete removal of existing treatment preparation of old plastered surfaces of wall applying 3mm thick wall care putty on wall and applying two coats of oil bond distemper over a coat of chalk whiting primer complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser Item No 48.00 above but on ceiling complete all as specified and as directed by Engr-in- Charge.
Complete removal of existing treatment preparation of old plastered surfaces of wall applying Two coats of acrylic emulsion paint over primer including 3mm thick wall care putty complete all as specified and as directed by Engr-in- Charge..
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including old tar felt etc and removing debris outside MOD land complete all as specified and as directed by Engr-in- Charge.
M&L for water proofing treatment with APP based polymeric membrane over 15mm thick plaster on roof with the following courses of treatment :- (a) Complete removal of existing treatment, cleaning & washing the concrete /tiles surface by using wire brush including junction of parapet etc. (b) M&L 15mm thick cement plaster in CM 1:4 using water proofing liquid as per manufacturer instructions over neat cement slurry @ 3kg/Sqm on roof surface. Note: Water proofing liquid /compound will be measured & paid separately. (c) Applying bituminous primer (IS 3384) @ 0.160 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (d) M&L for APP based polymeric membrane minimum weighing 3 kg/Sqm and minimum 3mm thick reinforcement with polyester non woven fabric (wt of reinforcement not less than 150gms/sqm) laid in primed surfaced application including preparation and applying two coats of Heat resisting Aluminium paint over APP membrane complete all as specified and directed.
M&L PCC 1:2:4 type C1 (12.5mm graded aggregate) in roof padding ccomplete all as specified and as directed by Engr-in- Charge.
Taking down chowkhats with shutters (without taking off shutters from the frame) area not exceeding 1.5 Sqm each, and removing from site complete all as specified and as directed by Engr-in- Charge.
All as per item No.54 above but area exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site complete all as specified and as directed by Engr-in- Charge.
Taking down shutters n.exc 1.00 Sqm each complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser item No. 56.00 above but n.exc 2.00 Sqm in each complete all as specified and as directed by Engr-in- Charge.
M&L for cutting holes in to brick wall built in cement mortar for inserting hold fast exc hlaf brick and n.exc one brick and making good to dismantled portion with PCC 1:2:4 type B1 or CM 1:3complete all as specified and as directed by Engr-in- Charge.
M&L for treating small articles such as stops, covers, gully gratings, holdfasts, ends of post, back of chowkhats etc with tar, coal tar black paint area exc 0.1 Sqm and n.exc 0.5 Sqm each complete all as specified and as directed by Engr-in- Charge.
S&F Mild steel ventilator fixed with glazzing bar complete all as specified and as directed by Engr-in- Charge.
S&F for 35mm thick 2nd class Hard wood glazed and skelton shutters as in Doors open rebated and prepare to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I section 8 clause 8.24 (a) complete all as specified and as directed by Engr-in- Charge.
M&L for 40mm th Flush shutters, solid core construction, with partical board core and plywood face panels, complete all as specified and as directed by Engr-in- Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, complete all as specified and as directed by Engr-in- Charge.
S&F pressed steel door frame of size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed by Engr-in- Charge.
S&F pressed steel door frame of size 105 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed by Engr-in- Charge.
M&L PCC 1:3:6 (12.5mm th stone aggrgate ) filling under pressed steel frame. complete all as specified and as directed by Engr-in- Charge.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified and directed by Engr-in- Charge.
S&F 2nd class Hard wood plain solid straight chowkhats, framed rebated on the solid rounded or chamfered , put to gether with glue, pinned at joints complete all as specified and as directed by Engr-in- Charge.
S&F Curtain rod wih brackets of fancy type 20mm dia anodised aluminum alloy conduit pipe complete all as directed
S&F for 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engr-in- Charge.
S&F MS Butt hinges 75 mm size as in windows chowkhats complete all as specified and as directed by Engr-in- Charge.
S&F mild steel 300mm sliding door bolts plate type stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, complete all as specified and as directed by Engr-in- Charge.
S&F 100mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engr-in- Charge.
S&F 150mm Extruded aluminium alloy handles, fabricated type,anodised complete all as specified and as directed by Engr-in- Charge.
S&F aluminium anodized barrel tower bolts of extruded section of length 150mm and fixed with cadymium plated wood series, complete all as specified and as directed by Engr-in- Charge.
S&F 200mm aluminium anodised barrel tower bolts stove enamelled black with bright bolt and fixed complete all as directed
S&F Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engr-in- Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares area not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Hacking out old broken glass of any thickness and size from the matel frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed by Engr-in- Charge.
M&L for preparing new surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engr-in- Charge.
M&L for 18/19mm thick Block boards, grade 2 quality, with decorative face veneer on both faces,, fixed with screws to timber frame-work complete all as specified and as directed by Engr-in- Charge.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flap (when open) 30mm complete all as specified and as directed by Engr-in- Charge.
M&L for 2nd class hard wood plain fillets exc 13 and n.exc 25 sqcm, square, rectangular or triangular in section clean swan secured with nails or brads and fixed in repairs complete all as specified and as directed by Engr-in- Charge.
Taking up or down 15 mm bore GI tubing and connection including cleaning for refixing or removal complete all as specified and as directed by Engr-in- Charge.
Taking up or down 20 mm bore GI tubing and connection including cleaning for refixing or removal complete all as specified and as directed by Engr-in- Charge.
Refixing old steel tubing and connection 15 mm bore in new or old position in wall, ceiling and floor etc complete all as specified and as directed by Engr-in- Charge.
S&F 15mm medium grade GI steel tubing including all fittings and fixed complete to wall ,ceiling and laid in floor etc complete all as specified and as directed by Engr-in- Charge.
Refixing old steel tubing and connection 20 mm bore in new or old position in wall, ceiling and floor etc complete all as directedcomplete all as specified and as directed by Engr-in- Charge.
S&F 20mm medium grade GI steel tubing including all fittings and fixed complete to wall ,ceiling and laid in floor etc complete all as specified and as directed by Engr-in- Charge.
S&F 15 mm dia stop cock of cast copper alloy but fancy type chromium plated screwed down high presser with crutch or butter fly handle on both ends for iron pipe or for union fixed complete all as specified and as directed by Engr-in- Charge.
S&F for Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engr-in- Charge.
S&F Bib taps, fancy type CP cast copper alloy with crutch or butter fly handle , screwed down, or secrewed for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in- Charge.
S&F 15mm bore pillar tap, cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixedcomplete all as specified and as directed by Engr-in- Charge.
S&F in repairs Waste coupling of PTMT 32 or 40mm and min wt 45 or 60gms complete all as specified and as directed by Engr-in- Charge.
S&F 10 ltr capacity PVC valve less symphonic action type flushing cistern, white ,with inlet ball valve, float and handle including bracket and 32 mm dia HDPE flush pipe and connected to squat pattern /pedestal pattern water closet (Flush shall be fixed at suitable height for smooth functioning ) complete all as specified and as directed by Engr-in- Charge.
S&F PVC connection 15mm bore with PTMT nuts and 750mm long. complete all as specified and as directed by Engr-in- Charge.
S&F in repair vitreous china wash hand basin, white flat back size 550x400mm complete including necessary cutting for and pinning in ends of brackets ) including brackets and 750mm long PVC waste pipe 32mm bore & waste coupling 32mm dia of PTMT (half or full threaded) complete all as specified and as directed by Engr-in- Charge.
S&F in repair vitreous china squatting pan `Orissa’ pattern, size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with ‘P’ or ‘S’ trap including provision of lime concrete bedding complete all as specified and as directed by Engr-in- Charge.
S&F 20 mm dia stop cock of copper alloy screwed down high presser with crutch or butter fly handle on both ends for iron pipe or for union fixed in repair CAT No. 8520 of Prayag or eqivalant jquar and hindware. complete all as specified and as directed by Engr-in- Charge.
S&F 110mm bore PVC bends of any radius complete all as specified and as directed by Engr-in- Charge..
S&F 75mm bore PVC SWR bends of any radius complete all as specified and as directed by Engr-in- Charge.
S&F 75mm bore PVC (SWR) vent cowl, complete all as specified and as directed by Engr-in- Charge.
S&F 110mm bore PVC (SWR) vent cowl, complete all as specified and as directed by Engr-in- Charge.
M&Lfor 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed by Engr-in- Charge.
S&F 75mm PVC SWR pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engr-in- Charge.
S&F 110mm PVC SWR pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engr-in- Charge.
Dismantling water tank of exc. 500ltr but n.exc 1000ltr capacity and removing from site. complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Item No 107.00 above but exc 250 and n.exc 500ltr capacity complete all as specified and as directed by Engr-in- Charge.
S&F rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered 500 Ltr capacity, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection. complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser Item No. 109.00 above but exc.500 and n.exc 1000ltr capacity complete all as specified and as directed by Engr-in- Charge.
S&F in repair Vitreous China wash down water closet pan (padestal pattern) white excluding flushing cistern, fixing bolt and flush pipe and including seat cover complete all as specified and as directed by Engr-in- Charge.
S&F in repair Glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with chromium plated brackets guard and railing 60cm long complete all as specified and as directed by Engr-in- Charge.
S&F in repair toilet paper holdervitreous China,box type complete all as specified and as directed by Engr-in- Charge.
S&F in repair Vitreous China half stall urinals bowel type (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 secuing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement, fixing automatic flushing cistern with brackets flush pipe grating and union fo dischage pipe (excluding of fixing supply pipe to flushing cistern, trap) including waste pipe complete all as specified and as directed by Engr-in- Charge.
S&F Tubular towel rail 20mm dia 600mm long CP including brackets complete all as directedcomplete all as specified and as directed by Engr-in- Charge.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15cm thick (below or above ground level), complete all as specified and as directed by Engr-in- Charge.
Dismantling floor hearth and wall tiles including cement mortar bedding (but not backing) and removing from site complete all as specified and as directed by Engr-in- Charge.
Taking down cement plaster on brick or stone wall including racking out joints hacking for key scrubbing down with the water etc, complete all as specified and directed by engineer-in-charge.
M&L for nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm in floors , set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all as specified and as directed by Engr-in- Charge.
M&L for joints free nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors , set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 6) complete all as specified and as directed by Engr-in- Charge.
M&L for double charged Vitrified Ceramic dark shade tiles 8 mm to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM (1: 6) complete all as specified and as directed by Engr-in- Charge.
S&F 450x300x7mm thick glazed ceramic joints free tile coloured on vertical surfaces such as skirting, dados, risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile over and including 10 mm thick cement mortar rendering in CM 1:4 complete all as specified and directed by Engineer -in- Charge.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm gradded stone aggreggate as in levelling course of flooring complete all as specified and as directed by Engr-in- Charge.
M&L for machine cut Kota stone slab flooring 20mm thick and over and incl 15mm thick screed bed in CM (1:6) cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and mirror polishing 7 cut as per local trade practice and cut to shape of required size complete all as specified and as directed by Engr-in- Charge.
M&L kota stone slab 20mm thick in riser of steps skirting, dado and pillar laid over cement screed and jointed including 10mm thick rendering in CM (1:4) complete all as specified and as directed by Engr-in- Charge.
M&L for 75mm thick PCC 1:3:6 type D-2 (using 40mm graded stone aggregate as in sub base of floor and path, Plinth protection complete all as specified and as directed by Engr-in- Charge..
M&L 12mm Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size suspended false ceiling incl GI powder coated grid work using 2.5mmx 23.5mmx1.5mm main tee, 25mmx23.5mmx1.28mm crossed Tee & 25mmx23.5mmx1.2mm angle fixed to wall for false ceiling incl necessary supporting hanger with 6mm dia GI wire & wire J bolts washer nuts for securing frame work to ceiling, suspended @ 125 cm C/C bothways, size of grid shall be 605x605mm complete all as manufacture instruction & specified & complete all as specified and as directed by Engr-in- Charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engr-in- Charge.
S&F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed by Engr-in- Charge. (each line wire to be measured)
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410- W(Gde- E-250) quality-A complete all as specified and as directed by Engr-in- Charge.
S & F Punched tape concertina coil of 1050 mm dia, 56 loops, 2.5 mm core wire, heavy galvanised (wire-275 GSM), tensile strength of wire 1450- 1500 N/Sqmm, (weight 15.20 Kg/Coil +/- 5%), stretchable length 6 m including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and as directed by Enginner-in-Charge.
M & L for Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed by Engr-in- Charge.
M&L for plain cement concrete 1:3:6 type C-2 (40mm graded stone agg) in surface channels and drains complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated Anodised aluminium frame for partitions, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.including sealing of window/door frames with sillicon gel to avoid rain water entry etc complete all as specified and as directed by Engr-in- Charge.
S & F Sheet Glass, Ordinary quality 5.5 mm Thick including necessary rubber beading fixed with screws to timber/aluminium frame complete all as specified and as directed by Engr-in- Charge.
M&L for 12mm thick Block boards, grade 2 quality, with decorative face veneer on both faces,, fixed with screws to timber / aluminium frame-work complete all as specified and as directed by Engr-in- Charge.
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc complete all as specified and as directed by Engr-in- Charge.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire complete all as specified and as directed by Engr-in- Charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc complete all as specified and as directed by Engr-in- Charge.
Taking down existing tube light fittings and disconnecting connection cable ends complete .complete all as specified and as directed by Engr-in- Charge.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and as directed by Engr-in- Charge.
One light point controlled by one switch. complete all as specified and as directed by Engr-in- Charge.
One Exhaust/Wall mounted /Ceiling point controlled by one regulator/switch complete all as specified and as directed by Engr-in- Charge.
One 3 pin socket 5 A on independent board. complete all as specified and as directed by Engr-in- Charge.
One 3 pin socket 5 A onsame board. complete all as specified and as directed by Engr-in- Charge.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping 25mm size with all fittings/fixture etc fixed wall and open recessed type Plastic switch board) made of robust Synthetic material Fire Proof, Anti corrosive & shock proof ISI Marked complet for housing one 15 A Switch / sockets complete all as specified and as directed by Engr-in- Charge.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar suitable for incomming MCCB and Out going MCBs including MCCB 100A 4 Pole 18 KA - 1 Nos complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 16 way 230 V with neutral link and with 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and with 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and as directed by Engr-in- Charge.
S&F MCB SP 240 volt 6 to 32 A 'C' series complete all as specified and as directed by Engr-in- Charge.
Supply and fix switch piano flush type 5 A one way. complete all as specified and as directed by Engr-in- Charge.
S & F Socket outlet 2 in 1, 3 pin, 5A flush complete all as specified and as directed by Engr-in- Charge.
Supply and fix switch piano flush type 15 A one way. complete all as specified and as directed by Engr-in- Charge.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 A flush type complete all as specified and as directed by Engr-in- Charge.
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal. complete all as specified and as directed by Engr-in- Charge.
Supply and fix Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connector and making prpper connections complete all as specified and as directed by Engr-in- Charge.
Supply & fix wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting. complete all as specified and as directed by Engr-in- Charge.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V , 1400 mm sweep complete all as specified and as directed by Engr-in- Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and as directed by Engr-in- Charge.
Taking down ceiling/wall/air circulator /padestal fans any type and size from the site by disconnecting all electrical connection ,and cleaning , rubbing by emery paper , servicing , oiling , greasing incl replacing small parts like bush/bearing etc and applying two coat spray painting complete and refixng on site making all nacessary connecrtion and testing for smooth functioning complete all as specified and as directed by Engr-in- Charge.
M & L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed.. ( Note :one run of phase, one run of neutral and one run of copper earth wire shall be measured & paid as one length.) complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser Item No 161.00 above but with 2x6.0 sq. mm + 1x4.0 sq. mm earth wire complete all as specified and as directed by Engr-in- Charge.
Ditto all as per Ser Item No 161.00 above but with 2x10.0 sq. mm + 1x6.0 sq. mm earth wire complete all as specified and as directed by Engr-in- Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in- Charge.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron wire 4 mm with GI protection pipe of 20 mm medium grade 7.5 meter long, etc complete all as specified and as directed by Engr-in- Charge. Note :i) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum.
Supply and fix 4 mm dia GI wire for earthing complete all as specified and directed
Supply and Install testing and commissioning complete hi wall split units indoor/outdoor complete with remote control unit and with inbuilt air ioniser and plasma filter for better indooor air quality of capacity 2 Ton inverter based Spilt Air Conditioners having copper tubing outdoor condensing unit incl wall mounting bracket working on 230 volts, 50 Hz, refregerent -R-134A/R-410a Eco Friendly Noise Level –Less than 40 db Mounting/ Fitting indoor & outdoor units at the respective locations as per standard practice including suitable copper tubing connection as required on site and thermal insulation Leak testing and additional refrigerant charge if required. electric driven single phase BEE 5 star rated all as specified and as directed by Engineer in Charge.
Suppy and fix voltage stabilizer transformer for low and high Voltage correction equipped with electronic transistorised relay suitable for correction, single phase AC supply complete with volt meter and designed for input voltage 170 Volts to 250 Votls and output voltage stablized between 215 Volts to 240 Volts of capacity ( 5 KVA )
M & L for Single pole and neutral enclosure with a two pin and earth plug and socket 240 V complete with one double pole MCB 20 Amps
Supply & fix (in Repalcement) energy saving and environmental frindly long life exclusive innovative flood light luminaries 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with LEDs as light source and lens embedded PC cover /toughened glass and impact resistance of IK07 and electronic driver fixed on high mast pole or any any other place as requird on site incl making all nacessary arrangement for fixing as required on site incl MS angle 50 x 50 mm cross arm with MS flat iron clamps made of MS flat of size 40 mm x 5 mm , nuts and bolts and washers duly painted with 2 coat of aluminium paint complete all as specified and directed
Ditto all as per Ser Item No 170.00 above but 30 Watt complete all as specified and directed
Supply & fix new junction box of size not less than 25Cm x20 Cm x 11 Cm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof, restricted to unauthorised tapping with class FV-0 as per IS : 11731 Part-II or V-0 as per UL-94 and fixing to pole etc using suitable clamps nuts, bolts etc for accommodating and including the following :- a) two Aluminium Bus bar of capacity 100 A , 10 CM long- 01 Set b) MCB SP 10A-01 Nos
S&F in replacement of PVC insulated 1.5 sqmm copper three core conductor cable from Junction box to light fittings drawn through the pole complete.
Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with black bituminous paint for embedded portion of pole incl drilling suitable holes required for passing of connection wires etc and numbering of pole complete all as specified and directed at site by Engr -in- Charge
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cable and getting out in hard/dense soil complete all as specified and as directed by Engr-in- Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm in hard dense soil obtained from excavation complete all as specified and as directed by Engr-in- Charge.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 10 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]
Supplying and laying Brick, flat, size 230mm x 110mm x 75mm for cable protection laind in trenches complete all as directed.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation or as per site reuirement at electical installations complete all as directed by Engr-in-Charge
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles or as per site reuirement at electical installations complete all as directed by Engr-in-Charge incl necessary form work using 20 mm graded stone aggregate etc
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete as directed
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete incl taking out unserviceable cable all as specified , for following size:-
16 Sqm 4 core
16 Sqm 2 core
10 Sqmm 2 core
Smruti Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .