Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.5 L+₹1.8 L (11.7%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹21.0 L+₹5.3 L (34.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹24.0 L+₹8.3 L (53.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹25.7 L+₹10.0 L (64.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Oct 2022, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
PERIODICAL SERVICES TO CERTAIN BUILDINGS IN VARIOUS UNITS AT GULPUR, SEKHLU AND NATU AND REPAIR/ REPLACEMENT TO E/M INTERNAL FITTING/ FIXTURE AND WIRING IN VARIOUS UNITS AT BG, HAMIRPUR AND JWG UNDER GE 881 EWS
2022_MES_554340_1
GE/PNH-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹60,000
Yes
4 Mar 2023
26 Sept 2022
1 Nov 2022
26 Sept 2022
25 Oct 2022
12 Oct 2022
Amount
B/R PORTION: Preparation of old plastered/ un-plastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified and directed.
All as per item No. 01 above, but on ceiling, complete all as specified and directed.
All as per item No- 01 above but applying one coat of oil bound distemper white or any tint, complete all as specified and directed.
All as per item No- 01 above but applying two coats of oil bound distemper white or any tint, complete all as specified and directed.
All as per item No- 01 above but applying two coats of Apex paint any tint, complete all as specified and directed.
M&L for complete removal of existing treatment, preparing surfaces plastered or unplastered old surfaces but applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS- 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over complete all as specified and directed.
M&L for applying two layer of wall care putty of approved make of 1 mm thick on walls as per manufacturer's instructions with and including rubbing by means of sand / abrasive paper to have smooth finishing to receive primer / paint, complete all as specified and directed.
M&L for preparation of old painted wooden or wood based surfaces of any description not otherwise described, over 10cm width or girth including knotting and stopping as required and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description (incl roof surfaces) not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for 15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plaster or unplastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS- 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces on walls complete all as specified and directed.
M&L for preparation of new plastered / unplastered surface of wall including cornices pilaster etc, and applying two coats of oil bound distemper, complete as specified and directed.
M&L for preparation of old or new plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smokw soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying two coats of camouflage painting on walls complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Dismantling and taking down unserviceable main switches, DB etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One ligh point controlled by two, two way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
One bell point controlled by one way switch 6 Amp complete all as specified and directed.
All as per srl item No 18 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp, two way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
S&F in repair electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified and directed.
S&F in repair surface mounted square LED panel of size 192mm x 192 mm x 23mm, aluminium die cast body with premium diffuser to ensure glare free & even distribution of light , of 18 watt capacity , lumen output 6000K, with pre-wired fitting complete all as specified and directed. Make : Havells cat part No. LHEAAWP7IL1WO18 or equivalent make as mentioned in PS
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repair gate light fittings, outdoor type, high power , 20 watt, IP65 luminaire, prewired with suitable pole for mounting complete all as specified and directed. Make: Havells cat part No. Coral Opal IP65 or equivalent make as mentioned in PS
Supply and fixing in repair LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair LED tube 20 watt (single side connection), 1213 mm long, suitable for installation in existing T8 tubelight batten, complete all as specified and directed.
S&F in repair of Inverter LED bulb 9 watt including all connected items complete all as specified and directed. Make of LED lamp:- Havells cat part No LHLDEGEDML8C009 or Equivalent Make of Philips/Bajaj cat part of make as specified in P.S.
S&F in repair LED driver suitable for 34 watt LED ceiiling light fittings and making connection to fitting complete all as specified and directed. Make:-Havells cat part No-LEDDRIVER36V36WS or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair single pole and neutral enclosure with a two pin and metal earth plug and socket complete with & incl one single pole MCB of 20 Amps complete all as specified and directed.
S&F sheet metal enclosure for DBs, vertical TPN double door (IP43), 4 ways built in bus bars suitable for 415 volts, AC, 50 Hz and suitable for FP MCCB as incommer and out going SP/TP MCBs complete all as specified and directed. Note:- MCBs shall be measured and paid separately.
S&F sheet metal enclosure for DBs, SPN double door (IP43), 4 ways built in bus bars suitable for 240 volts, AC, 50 Hz , including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB TPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCTNF040 - DHMGCTNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
S&F heavy duty metallic exhaust fan 380/200mm sweep 1200 RPM, single phase 240 Volts including all connecting accessories, complete and taking out old existing exhaust fan, complete all as specified and directed.
S&F in repair of PVC counduit non matalic rigid, of size 25 mm dia (external) incl all accessories use for fixing of conduit on wall and ceiling etc, complete all as specified and directed.
S&F in repair PVC casing caping of size 25 mm incl all fixing accessories complete all as specified and directed.
S&F in repair flexible PVC conduit of approved quality of size 25 mmbore with fixing materials, complete all as specified and directed.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in repair Sub main wiring with single core cable 2x 4 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 4 sqmm and one run of PVC conduit/casing caping shall be measured as one unit.
S&F in repair Sub main wiring with single core cable 2x 6 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 6 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 6 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core & including taking down old old unsv service cable connection, complete all as specified and directed.
S&F in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 10 Sqmm 2 core including taking down existing old service connection, complete all as specified and directed.
Repair and maintenance of unserviceable ceiling fan of 1200mm/ 1400mm sweep at contractor's work shop, incl dismantling complete the ceiling fan parts, inspecting serviceability of all the parts, refixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, bracket, rubber bush, connecting wire, PVC connector, aluminium clamp for rod, bracket, bush rod, greasing/oiling etc assembling, cleaning and testing of ceiling fan complete all as specified and directed. Note: (i) Unserviceable parts as above shall be measured and paid separately under relevant items No 57 to 65 of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Cost of minor part i.e. Cotter pin, screws shall be deemed to included in the cost of quoted rate.
Supply only bearing good quality for ceiling fan 1200mm/1400mm sweep ISI marked complete all as specified and directed.
Supply only Gun metal bush for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Supply only capacitor 2.5 mfd ISI marked complete all as specified and directed.
Supply only brass bracket assy for hanging the ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Supply only 3 core flexible wire 40/.0076, white colour from ceiling rose to fan connector complete all as specified and directed.
Supply only stator shaft for ceiling fan complete all as specified and directed.
Supply only fan blade for ceiling fan 1200 mm sweep of existing make complete all as specified and directed.
Supply only fan blade for ceiling fan 1400 mm sweep of existing make complete all as specified and directed.
Supply only canopy (top/bottom) of ceiling fans any make /size of colour matching with existing canopy/ fan colour complete all as specified and directed.
M&L for removing of old burnt winding of any size , type and rewinding of stator winding with superior quality copper wire with insulation complete all as specified and directed.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
M&L for Replacement of down rod of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.45 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality complete all as specified and directed by Engineer in charge.
All as per item No 68 above but of length 0.60 Mtr complete all as specified and directed.
Repair and maintenance of unserviceable exhaust fan of any cap and sweep by dismantling the exhaust fan parts, inspecting the serviceability of parts, refixing of serviceable parts after cleaning, replacement of unerviceable parts i.e. beaing, bush, capacitor, connecting wires, fan blade, locknut, rubber pad etc, oiling/greasing, cleaning and testing of exhaust fan complete all as specified and directed. Note: (i) Unserviceable parts replaced shall be measured and paid separately under relevant items No 71 to 73 of Sch 'A' as supply only. (ii) Rewinding of stator winding shall be measured & paid for separately under relevant item of Sch 'A'. (iii) Cost of minor part i.e. screws shall be deemed to included in the cost of quoted rate.
Supply only double ball bearing (ISI marked) for exhaust fan of 200 mm sweep to 450 mm sweep fan complete all as specified and directed.
Supply only gun metal bush for Exhaust fan of any capacity. complete all as specified and directed.
Supply only blade of exhuast fan of 200 mm sweep to 450 mm sweep as per existing make complete all as specified and directed.
M&L for rewinding of 450mm sweep exhaust fan motor with superior quality copper winding wire with insulation complete all as specified and directed.
M&L for rewinding of 300mm sweep exhaust fan motor with superior quality copper winding wire with insulation complete all as specified and directed.
M&L for preparation of painted surfaces of exhaust fan of any make and size by scrubbing old and applying one coat of synthetic enamel paint by spray painting complete all as specified and directed by Engr-in-Charge.
Disconnecting electric & water connection to geyser of capacity 25/35/50 litr, taking down from existing position, dismantling and inspecting all the parts for its serviciability, cleaning of serviceable parts i.e. heating element, base assembly, connecting lead, thermostat, electric contact, electric wiring, indicators, safety valves etc re-fixing in the same in position, testing complete all as specified and directed by Engr-in-Charge. Notes: (i) The defective parts to be replaced shall be measured and paid separately under relevant item No 78 to 89 of Sch 'A' as supply only (ii) Cost of minor items i.e. screws, nuts, bolts etc shall be deemed to be included in this item
Supply only heating element of capacity 2 KW, ISI marked with rubber gasket suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only heating element of capacity 1.5 KW, ISI marked with rubber gasket suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only thermostat, ISI marked suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only indicator lamp suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only geyser safety valve suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only PVC pipe connection of heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature complete all as specified and as directed.
Supply only aluminium/chromium type flexible connection, heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature complete all as specified and as directed.
Supply only inner tank made out of steel sheet conforming to IS, suitable for 25 litres capacity of geyser, vertical type complete all as specified and as directed.
Supply only inner tank made out of steel sheet conforming to IS, suitable for 35/50 litres capacity of geyser, vertical type complete all as specified and as directed.
Supply only non return valve made out of brass fixed in vertical position of suitable dia complete all as specified and as directed.
Supply only new base assembly with inlet and outlet pipe made out of steel sheet with gasket and proper size of nuts, bolts and washer etc suitable for 25 litres capacity of geyser complete all as specified and as directed.
Supply only new base assembly with inlet and outlet pipe made out of steel sheet with gasket and proper size of nuts, bolts and washer etc suitable for 35/50 litres capacity of geyser complete all as specified and as directed.
S&F in repair decorative flood light 30 W, for mountain with multicolour LED bulb of IP 65 protection, 230 volt 50 Hz, water proof and rubber gasket complete all as specified and as directed.
M/S Chib Engineers
VIKAS ENTERPRISES
M/s Anil Engineers & Builders
M/S Farooq Ahmed Bhat
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .