Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.9 L+₹3.5 L (18.1%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹23.9 L+₹4.5 L (23.1%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹25.7 L+₹6.3 L (32.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹37.8 L
EMD Value
₹75,650
Closing Date
16 Nov 2024, 6:00 pmClosed
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF INTERNAL ELECTRIFICATION, FITTING AND FIXTURES AND OTHER CONNECTING ITEMS AND COMPREHENSIVE MAINT/PETTY REPAIR OF INTERNAL ELECTRICAL COMPLAINTS AT DGQA AREA UNDER GE (I) KANPUR
2024_MES_680300_1
GE(I)/KAN/T-79 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I) KANPUR
₹75,650
Yes
20 Jan 2025
19 Oct 2024
23 Nov 2024
19 Oct 2024
16 Nov 2024
2 Nov 2024
Amount
Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to urgent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed. Notes :- This item is applicable only where no material is required. 1. The site for attending complaints at DGQA Area, ASC deopt, Napier Rd, Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830 hrs to 1700 Hrs including holiday and Sunday. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm complete all as specified and directed.
All as per item No 2 above but size 2.5 Sqmm complete all as specified and directed.
All as per item No 2 above but size 4 Sqmm complete all as specified and directed.
All as per item No 2 above but size 6 Sqmm complete all as specified and directed.
All as per item No 2 above but size 10 Sqmm complete all as specified and directed.
M&L for switch piano flush button single pole one way 5 amps 240 volts complete all as specified and directed.
Switch piano flush button single pole one way 15 amps 230 Volts complete all as specified and directed.
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts complete all as specified and directed.
Switch modular type one way 1 module 16 amps 230 Volts complete all as specified and directed.
M&L for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts complete all as specified and directed.
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts complete all as specified and directed.
S&F modular white cover plate with frame 2/3 module complete all as specified and directed.
S&F modular white cover plate with frame 4 module complete all as specified and directed.
S&F modular white cover plate with frame 6 module complete all as specified and directed.
S&F imodular white cover plate with frame 8 module complete all as specified and directed.
S&F modular white cover plate with frame 12 module complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
S&F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
Supply and fixing in replacement electronic, step type hum free fan regulator suitable to control speed of fan from 0 to 100% and connecting electrically all as required or complete all as specified and directed.
Supply and fixing in replacement modular fan regulator steped type 220 V complete all as specified and directed.
Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts complete all as specified and directed.
Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts complete all as specified and directed.
Supply & fix in replacement hylem sheet cover 3 mm thick of size 7"x4" including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed.
All as per item No 26 above but of size 8"x10" complete all as specified and directed.
All as per item No 26 above but of size 11"x9" complete all as specified and directed.
All as per item No 26 above but of size 13"x11" complete all as specified and directed.
S&F in repair sunken box size 3"x5" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 4"x7" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 7"x9" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts, including one single pole MCB of 25 amps earthing complete all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
All as per item No 34 above but for 8 way complete all as specified and directed.
M&L for MCB single pole 240 volts 6 to 32 amps, with rapturing capacity 10 KA using thimbles of required size complete all as specified and directed.
S&F MCB SP 63 Amps, 10 KA, 'C' Series complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 40 amps,with rapturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 63 amps,with rapturing capacity 10 KA using thimbles of required size complete all as specified and directed.
S&F MCCB 125 Amps capacity, 4 pole, 16 KA, fixed thermal and magnetic release and extended terminals to be fixed in 8 way TPN DB complete all as specified and directed.
All as per item No. 40 above but capacity 100 Amps, fixed thermal and magnetic release, 4 Pole, 16 KA suitable to be fixed in 4 way TPN DB complete all as specified and directed.
Supply and fixing 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast PVC housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required and complete all as specified and directed.
Supply and fixing in repair surface and wall mounted LED Tube light & fitting 20 watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with provision PVC copper wire 1.5 sqmm 3 core of required length upto ceiling rose complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted 36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection with making electrical connection with three core copper wire to ceiling rose properly complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted 31/32 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making making electrical connection with making electrical connection with three core copper wire to ceiling rose properly complete all as specified and directed.
M&L for Surface mounted LED down lighter 12 watts with white powder coated polycorbonate housing and pressure die cast heat sink having high efficiancy complete all as spcified and directed.
S&F in replacement of LED post top globestarmade up of unbreakable polycarcarbonate suitable for mounting on gate with led bulb 12 W with proper arrangements and making electrical connection complete all as specified and directed.
S&F LED bulb of 9 watt, 240 V 50 Hz complete all as specified and directed.
Supply and fix LED invertor bulb 15 watt, 240 V 50 Hz complete all as specified and directed.
S&F distribution board iron clad, double door with IP-43 1K-09 protection(VTPN) suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, with appropriate size copper bus bar and neutral link, with provision of one MCCB 4 pole 415 Volts & MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with box complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with box complete all as specified and directed.
S&F Switch socket combination 2in 1, 5 A flush types complete all as specified and directed.
S&F Switch socket combination 2in 1, 15 A flush types complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through existing concealed conduit in / on wall/ceiling including 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for one light point controlled by one 05 Amps switch complete all as specified and directed.
All as per item No. 56 above but one fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 56 above but one socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No. 56 above but one socket out multi pin 5 Amps controlled by one switch on same board complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including concealed conduit in/on wall/ceiling including 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for one light point controlled by one 05 Amps switch complete all as specified and directed.
All as per item No. 60 above but one fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 60 above but one socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No. 60 above but one socket out multi pin 5 Amps controlled by one switch on same board complete all as specified and directed.
All as per item No. 60 above but one calling bell controlled by one bell push complete all as specified and directed.
All as per item No 60 above but for one socket out let 2 in 1, 5 and 15 Amps or AC point with 4 Sqmm PVC copper conductor including 4.0 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
All as per item No 60 here in before but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including rigid PVC conduit/ Casing caping on wall/ceiling with and including provision of MS box of suitable size with 3mm thick laminated hylam sheet cover for housing switch, socket, etc incl provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for one light point controlled by one 05 Amps switch complete all as specified and directed.
All as per item No. 67 above but One light point controlled by Two Nos of 2 way switch 05 Amps complete all as specified and directed.
All as per item No. 67 above but One fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 67 above but One socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No 67 here in before but for one socket out let 2 in 1, 5 and 15 Amps or AC point with 4 Sqm PVC copper conductor including 4.0 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
All as per item No 67 here in before but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor includuing 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade of size 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
All as per item No 73 above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit complete all as specified and directed.
All as per item No 73 above but for cable of size 10 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm in & including concealed PVC conduit complete all as specified and directed.
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 10 Sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade of size 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed.
All as per item No 76 above but for cable of size 16 sqmm aand one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit complete all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor 16 sqmm nominal cross section twin core for service connections complete all as specified and directed.
All as per item No 78 above but cable of size 10 Sqmm 2 core complete all as specified and directed.
All as per item No 78 above but cable of size 6 Sqmm 2 core complete all as specified and directed.
M&L for metal clad plug top having 2 pole and earh 20/25 A for sheet metal enclosure complete all as specified and directed.
M&L in replacement of earthing with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil and removal of surplus excavated material all as required from site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion complete all as specified and directed.
AARADHIRAJ ASSOCIATES (BID ID -3166686)
S B ENTERPRISES (BID ID -3167210)
M/S G S Gupta and Sons (BID ID -3166808)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .