Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.1 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L-2₹16.1 L+₹2.0 L (14.3%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L-2 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹49,960
Closing Date
22 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
REPAIR/MAINT OF DG SET AND CONNECTED ITEMS INSTALLED AT NIMU, NURLA, SANGAM HILL AND NANAK HILL MIL STN UNDER AGE(I)NIMU
2023_MES_586562_1
80051/168/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Nimu
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
AGE(I) NIMU
₹49,960
3 May 2023
21 Mar 2023
24 Apr 2023
21 Mar 2023
22 Apr 2023
4 Apr 2023
Amount
Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of capacity 500 KVA DG Sets at 25 Grndr & Power house for smoth functioning complete all as per manufacturers instructions and all as directed by Engr - In - Charge (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightness of alternator (k) checking the function of AVR general checks
(l) Checking of control panel meters and gadgets functioning (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE : (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (3) Make of spare recommendation by auth service centre of manufacturer
'V' belt for water pump
Fuel pipe with banjo bolt at both side
Oil filter element
Air cleaner element (inner and outer)
Fuel filter element (primary and secondary)
All as per Srl item No. 1.00 here-in-before but DG Set of capacity 180 KVA. and Supply only following consumable spares parts in repair.
'V' belt for water pump
Fuel pipe with banjo bolt at both side
Oil filter element
Air cleaner element (inner and outer)
Fuel filter element (primary and secondary)
All as per Srl item No. 1.00 here-in-before but DG Set of capacity 160 KVA. and Supply only following consumable spares parts in repair.
'V' belt for water pump
Fuel pipe with banjo bolt at both side
Oil filter element
Air cleaner element (inner and outer)
Fuel filter element (primary and secondary)
All as per Srl item No. 1.00 here-in-before but DG Set of capacity 125 KVA and Supply only following consumable spares parts in repair.
'V' belt for water pump
Fuel pipe with banjo bolt at both side
Oil filter element
Air cleaner element (inner and outer)
Fuel filter element (primary and secondary)
All as per Srl item No. 1.00 here-in-before but DG Set of capacity 62.5 KVA and Supply only following consumable spares parts in repair.
'V' belt for water pump
Fuel pipe with banjo bolt at both side
Oil filter element
Air cleaner element (inner and outer)
Fuel filter element (primary and secondary)
All as per Srl item No. 1.00 here-in-before but DG Set of capacity 40 KVA and Supply only following consumable spares parts in repair.
'V' belt for water pump
Fuel pipe with banjo bolt at both side
Oil filter element
Air cleaner element (inner and outer)
Fuel filter element (primary and secondary)
S&F in replacement Dynamo/Alternator Assy for capacity 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 7.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 7.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 7.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement auotmatic voltage regulator(AVR) 24 volt suitable for 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 8.00 here-in-before but DG Set of capacity 180 KVA
All as per Srl item No. 8.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 8.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 8.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 8.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement self starter of capacity of 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 9.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 9.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 9.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 9.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Turbo Charger assy for 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 10.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 10.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 10.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Fan Hub assembely for capacity of 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 11.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 11.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 11.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement lub oil pump suitable for Capacity 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 12.00 here-in-before but for Capacity 160 KVA DG Set.
All as per Srl item No. 12.00 here-in-before but for Capacity 62.5 KVA DG Set
All as per Srl item No. 12.00 here-in-before but for Capacity 40 KVA DG Set
Strip opening of alternator of Capacity 500 KVA DG Set at Power house No-01, removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material. Note:- Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
All as per Srl item No. 13.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 13.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 13.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Piston/Ring set suitable for 500 KVA DG Setcomplete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 14.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 14.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 14.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 14.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Cylinder Liner set suitable for 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 15.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 15.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 15.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 15.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Valve guid for 500 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 16.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 16.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 16.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 16.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Fuel spray nozzle suitable for capacity of 500 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 17.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 17.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 17.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement Head Gasket suitable for capacity of 500 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 18.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 18.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 18.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 18.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement came bush for 500 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 19.00 here-in-before but DG Set of capacity 160 KVA
All as per Srl item No. 19.00 here-in-before but DG Set of capacity 125 KVA
All as per Srl item No. 19.00 here-in-before but DG Set of capacity 62.5 KVA
All as per Srl item No. 19.00 here-in-before but DG Set of capacity 40 KVA
S&F in replacement battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
S&F in replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging Complete all as specified and directed by Engr-in-Charge. Make- Exide/ Amron or equivalent
S&F in replacement Battery 12 Volt 80 AH (Maint free heavy duty with initial charging Complete all as specified and directed by Engr-in-Charge. Make- Exide/ Amron or equivalent
M&L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing suitable for for 500 KVA DG Set complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 23.00 here-in-before but DG Set of capacity 180 KVA.
All as per Srl item No. 23.00 here-in-before but DG Set of capacity 160 KVA.
All as per Srl item No. 23.00 here-in-before but DG Set of capacity 125 KVA.
All as per Srl item No. 23.00 here-in-before but DG Set of capacity 62.5 KVA.
All as per Srl item No. 23.00 here-in-before but DG Set of capacity 40 KVA.
M&L for cleaning of radiator of 500 KVA DG sets by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/ brezzing and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 24.00 here-in-before but DG Set of capacity 160 KVA.
All as per Srl item No. 24.00 here-in-before but DG Set of capacity 125 KVA.
All as per Srl item No. 24.00 here-in-before but DG Set of capacity 62.5 KVA.
All as per Srl item No. 24.00 here-in-before but DG Set of capacity 40 KVA.
Supply only Engine oil 20 W 40 of best quality complete all as specified and complete by Engineer-in-Charge.
Supply only coolent of best quality complete all as specified and complete by Engineer-in-Charge.
Supply only distilled water of best quality in 05 litrs sealed gallon packing complete all as specified and complete by Engineer-in-Charge.
Note:-(i) The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 89,350.00 and any other reduction if any from quoted amount. (ii) In case manufacturers as mentioned in list of makes does not manufactur item as per given description, then items of higher specification will be specified without any financila adjustment.
M/S TRADE LINK
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .