Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.1 L+₹1.2 L (4.64%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹29.1 L+₹2.3 L (8.44%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹30.3 L+₹3.5 L (13.0%)Rejected-Finance NH 44 BUILDING COLONY NO 01 SUJANPUR TEH DISTT PATHANKOT PUNJAB 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹30.4 L+₹3.6 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Feb 2023, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
REPAIR TO JOINERY ROOFING LEAKAGE SEEPAGE FLOORING ETC IN OTM ACCN OF DHANGU COMPLEX AND 167 MH UNDER GE S PATHANKOT
2023_MES_573750_1
GES/PKT/T-64/2022-23
Open Tender
Construction Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹80,000
Yes
6 Mar 2023
7 Jan 2023
6 Feb 2023
7 Jan 2023
4 Feb 2023
23 Jan 2023
Amount
Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed.
All as per description of item 2 above but except bricks complete all as specified and directed
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for 15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat complete all as specified and directed.complete all as specified and directed
Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC complete all as specified and directed.
All as per Ser item 6 abve but area exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm and not exc 2.00 Sqm each complete all as specified and directed.
S&F pressed steel frame for door made out of MS sheet 1.25mm thick of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl PCC 1:3:6 for back filling of chowkhat etc complete all as specified and directed.
S&F pressed steel frame for doors made out of MS sheet 1.25mm thick of size 125mmx60mm for with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl PCC 1:3:6 for back filling of chowkhat etc complete all as specified and directed.
S&F steel window/ventilator with tubular frame factory made double shutters of size 79mm x 39mm, 16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 75 mm long and 10mm square bar grills complete, including mild steel wire cloth 0.56mm nominal dia and average width of aperature 1.18mm,including sheet glass 3 mm thick with glass oil putty and glass pins,including two coats of synthetic enamel paint over one coat of red oxide primer including sufficient nos of PCC bed blocks in pcc 1:2:4 (using 12.5mm gradded aggregate) for fixing hold fast
S&F 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, fitted to chowkats,including door hinges,sliding bolt,door handle,tower bolt & including two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F 35mm thick 2nd class hard wood in glazed and Skelton factory made shutters open rebated and prepared to receive glass/wire gauge etc with sash bars edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass/wire mesh etc sizes of members as per clause 8.20(a) of SSR Part-I including glavinized mild steel wire cloths 0.56mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or glavinized wire staples,,including door hinges,sliding bolt,door handle,tower bolt & including two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. complete all as specified and directed.complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.Note :- Door frame shall be water proof, terite proof, elegant and should have excellent screw holdig strength to fix hinges abnd hold doors properly fora long life)
S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 5 mm thick Moulded Prelam PVC Sheet on the front face & 5 mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing suppling & fixing in the frame at site as per specification & drawing including all fittings complete all as specified and directed by Engr-in-Charge.
S&F Anodised aluminium powder coated frame of any colour (Thickness or powder coating not less than 50 micron for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F Anodised aluminium powder coated door shutters of any colour (Thickness or powder coating not less than 50 micron aluminium section weighing not less than 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc including 5mm thick tinted glass in door/window shuters with aluminium beading/glazing clip of both side complete all as specified and directed.. complete all as specified and directed by Engr-in-Charge.
S&F Anodised aluminium powder coated window of any colour (Thickness or powder coating not less than 50 micron and ventilator shutters, openable/side hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.including peg stays 150mm long (2 no minm .) minm 3 nos aluminium tower bolt 75 mm long ,aluminium handle 2nos 125 mm,hinges 100mm long (minm 2 nos.) including 5mm thick tinted glass in door/window shuters with aluminium beading/glazing clip of both side complete all as specified and directed.. complete all as specified and directed by Engr-in-Charge..
Supply and fixing 4mm thick aluminium composite panel (coloured sheet) and in additional other accessories for fitting in aluminium partition / doors / windows / ventilators /sliding shutters etc complete all as specified and directed by Engr-in-Charge
S & F in repair door closer hydraulically regulated, designation No. 3, universal type, Aluminium body suitable for door shutter of 851 to 1000mm in width & of weight between 61 to 81 kg & fixed Aluminium (Die cast) body
Dismantling of wall tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,including M&L for providing glazed ceramic coloured wall tiles of exterior quality of size 450mmx350mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,including M&L Non skid ceramic colour tiles 7 to 8 mm thick ( sq/ rect) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises, including M&L vitrified ceramic tiles light shade 10 mm thick ( sq/ rect) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,M&L vitrified ceramic tiles 10 mm thick ( sq/ rect) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in verticle surfaces like skirting/dado, steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water,M&L for Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement mixed with and including water proofing coumpound including formwork upto 7 M height with two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat complete all as specified and directed.complete all as specified and directed.(Note:- The rate included for WPC )
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water,M&L for Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Material and labour for complete removal of existing treatment internally surface of wall and applying min 1.5 mm thick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of oil bound distemper without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water,M&L rendering 10mm thick on concrete in CM 1:3 in facia or edging of chajjas,ceiling and roof projection making the line in true shape finished even & smooth without using extra cement including formwork upto 7 M height and applying three coats of white wash complete all as specified and directed.
Taking down cement plaster on concrete surface of chajja or facia , any description at any height ,M&L rendering 10mm thick on concrete in CM 1:4 in facia or edging of chajjas, (width/height not exceeding 45 cm ) to protect movement of water inside and act in place of damaged drip course including prepration of new surface and applying two coats of cement base paint all as specified and directed.
M&L for preparation of old plastered or un-plastered surface of wall up to four storeys height of buildings including cornices etc by brooming or steel wire brushing,scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paint on wall including curing of any shade complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall including cornices pilasters by brooming down with steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent salt and trading oil & greasy spots etc and applying two coat of oil bound distemper on wall complete all as specified & directed.
Preparation of old plastered or unplastered surfaces of ceiling including cornices pilasters by brooming down with steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent salt and trading oil & greasy spots etc and applying one coat of oil bound distemper on ceiling complete all as specified & directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
M&L steel work in tublar trussed incl special shaped washers etc complete using ERW or induction butt welded tubes conferming to IS 1161-1979 gde St -240 incl purlines incl two coat of synthetic enamel paint overa coat of red oxide complete all as specified and directed.
M&L steel work in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) Forming holes with riveted,bolted,or welded attachments complete all as spd and directed by eng.in.charge.
M&L PCC 1:4:8 type D-2 using 40mm graded agg. as in foundation filling and mass concrete complete all as specified.
Excavation in post holes not exceeding 0.50cum getting out in Hard/dense soil, returning,filling in layers not exceeding 50 mtr and making good surfaces all as soecified.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings,M&L Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings,M&L pre painted galvalume aluminum zinc coated GI based plain steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, Providing and fixing tiled flase ceiling of size 595x595 mm incl of ceiling tiles in true horizontal level suspended on inter locking matrix 32 mm matel grid of hot dipped galvanised steel sections (galvanised @120gms per sqm both side incl) consisting of 3600mm long main "T" of size 24x25mm and 0.30mm thick and PPGI sheet wall angle of size 24x24mm and 0.40mm thick. Bottom exposed capping of width 24mm of all T sections shell be 0.25mm thick. PPGI wall angle is fixed aling the perimeter of ceilings to walls, partition or columns etc with rawl plug and wooden secrews at 300mm denters. Main T runners are than suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12mm dia and 38mm long dash fatners, 6 mm threaded rod with bolt for hangers spaced at max 1200 mm center to center along main T and not more than 150mm with slipped joints, the last hanger at the end of each main runner should not be greater than 600mm from adjecent wall. than 1200mm long cross T is interlocked between the main T at 600 mm center to center to form at grid 1200x600mm and than secondary cross of length 600mm is interlocked at middle of 1200x600mm grid to form grids of 600mmx600mm . cross T at the ends having length more than 600mm are to be supported independently. Finally PVC laminated with aluminium foil back board tiles of size 600x600x8mm thick tiles having light refectors of >=75% are placed in the grid incl dismentling of wall and ceiling board (fiber, pulp, insulation, etc) or insulation boards/ slabs/ blanket, any thickness complete all as specified and directed.
All as per srl no 40 above but except false ceiling tiles of any size, shape and specifications all as directed by engr in charge.
All as per srl no 40 above but except grid of false ceiling of any size, shape,specifications all as directed by engr in charge.
Roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc with and including taking out existing roof treatments, brushing neat cement slurry with 3.0 Kg of cement per sqm and providing 10mm thick rendering in Cement mortar 1:4 on fair faces of concrete, finished even and fair mixed with and including water proofing compound to receive treatment on roof Providing and laying of water proofing treatment of roof APP (Atactic Polyproplyllen) modified prefabricated five layer 3mm thick water proofing membrane, with non woven polyester mat reinforcement of 160 gsm, weight of membrane @ 3.6 Kg/Sqm over a solvent based bitumen primer, @ 0.3 Ltr Sqm by the same manufacturer conforming to IS:3384-1986 , The membrane shall be laid using bitmun torch.The end lap should be 100 mm and the side lap must be minimum 75 mm the membrane shall be first laid up to the parapet wall junction and then shallbe overlapped with another membrane (flashing) with an overlap covering up to a distance of 300mm. In case parapet height is less than/ up to 500 mm, membrane shall be terminated at the top of parapet.All rain water pipe opening shall be suitably sealed with the APP membrane including two coat of silver paint all as specified and directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) (Note:- The rate included for WPC )
Demolition of cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L 50mm thick PCC, type B-1, 1:2:4, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement complete all as specified and directed.
Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and providing applying two coats of rust remover and two coat of alkaline rust converting primer/zinc primer and form a corrosion resitant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats use.
In Column/Wall
In Beams
In Slab/roof projection
Providing and applying, brush application, curing to form anticorrosive with high bond strength of anticorrosive polymer modified cementitious coating for corrosion inhibiting protection of reinforcement in one layers of total thickness of 2 mm.
In Column/Wall
In Beams
In Slab/roof projection
Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness exceeding 40 mm but not exceeding 100mm by providing and casting with pre-packed dual shrinkage compensated micro concrete of minimum grade of M40 and above including providing and fixing of watertight foam faced finish shuttering all lead and lift mixing placing, deshuttering, levelling the surface by grinding off cementitious slurry of construction joints of differences in any to satisfaction of Engr-in-charge, curing etc, complete all as specified.
In Column/Wall
In Beams
Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness not exceeding 60 mm in layers of min thickness exceeding 20 mm and avg thickness 40 mm each by providing and applying ready mised duel shrinkage compensated thixotropic mortar (PMM) of minimum grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing etc complete all as specified.
In Slab/roof projection
Demolition of stone slabs, paver blocks and tiles of any description or thickness in floors/apron laid dry complete all as specified and directed.
S&F machine pressed precast concrete interlocking paver blocks with grey cement and no pigment, any shape and size conforming to IS 15658:2006 of 60 mm thickness M35 grade complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Chequered cement concrete coloured, table vibrated chemical coated, tiles 300mm x 300 mm x 25 mm thick table set and jointed, pointed in neat cement slurry with grey cement and no pigment as in floor,Screed bed or bedding layer of 20 mm thick CM (1:6) as in floor, complete all as specified and directed.
Cement concrete type B1 1:2:4 (using 20mm graded crushed stone agg) 75 mm thick as in floor,floor tile etc finished surface even and smooth without using extra cement complete all as specified and directed.
S&F in repair bib taps/angle valva/pillar tap standard of PTMT any colour high pressure screwed for iron pipe of 15mm bore complete all as specified and directed.
Refixing Aluminum frame with suitable rawl plugs with brick/concrete wall all as per direction of Engineer-in -charge including finishing Jams surface with existing wall surface all as specifed.
Refixing Aluminum shutter of any dscription exc 1.00 Sqm n exc 2.50 sqm each after Easing and adjusting by opening all side members and refix with cleats and screw in true alignment including existing fitting/fixtures as in the same opening complete with Aluminum frame all as specifed & directed
S&F in repairs vitreous china wash down water closet (pedestal pattern) including fixing bolts and connecting to drain pipe including seat cover plastic flat bottom and connection to flush pipe, anti syphonic pipe etc complete all as specified and directed.
S&F in repairs 10 litres PVC low level flushing cistern syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm dia flush pipe with coupling inc pvc connection and fixed complete all as specified and directed.
M&L for hard core of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surfaces complete.
Material and Labour for remove all loose gravel cement mortar, dirt, oil, grease and foreign material by jet of dry air and clean the surface mechanically or by grinding to make it smooth before application loose existing bituminous material manually and with heal torch gun to get smooth plain finished surface with no loose material on surface. Repair all joints & cracks with highly elastic bituminous cold applied putty tarplasic-- having penetration after setting upto 8mm Levelling of surface to give proper slope will be done as per site requirements with Shalipatch cold applied, Bituminous Motor & Cold emulsion cum waterproofing liquid--- Shalikote T-10, Created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make of approved by GE mixed with portable water in the ration of 1:1 and apply @ 400gm per Sqm (As per surface conditions).* Apply first coat of Tarfelt LM or equivalent make of approved by GE having elongation 200% conforming to ASTM-C-412 & having crack bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no dilation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm. * Lay Geotex of 45 GSM/Fibre mesh simultaneously and paste it properly with overlap of 50mm. * Allow the first coat to dry for 10 to 12 Hrs. * Apply 2nd coat on cured first coat with consumption @ 700gm per Sqm in opposite direction of first coat by Brush or Roller. * Allow it to dry for 10-12hrs after apply 3rd coat with consumption @ 700gm per Sqm.
Ensure final curing time of 36 hrs before allowing/carrying out any further work,. Conduct ponding test after min 7 day applying two coats of U V Resistant Elastomeric Exterior Acrylic Weather resistant water proof coating of Shalicryl-215 or equivalent make of approved by GE having elongation of 300% after curing of 14 days conforming to ASTMD-6083—for U V Protection of Bituminous Elastomeric Acrylic Emulsified Liquid Membrane of Tarfelt LM or equivalent make of approved by GE to give long life and prevent its deterioration from sunlight.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
Amarjit Brothers
malghotra construction co
HARI OM ENTERPRISES
Jay Ann Construction Company
VIKRAM SINGH MANHAS
M/S Ajay Kumar Mahajan
M/S BISHAN DASS AND SONS
VIJAY CONSTRUCTION CO
Balaji Engineers
M/S RUDHRAKSH TRADING CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .