Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-Finance | L1 | Accepted-Finance BEING LOWEST | |
| 2 | L2₹15.8 L+₹21,728.20 (1.39%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹19.8 L+₹4.2 L (26.7%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹22.5 L+₹6.9 L (44.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹23.5 L+₹7.9 L (50.7%)Rejected-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | L.K.R.TIWARI CONSTRUCTION L1 | OM SAI ASSOCIATES L3 | vishalconstruction L5 | Shri Sant Cosntruction L4 | Mukund Engineers and Contractors L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling G.S. Sheet plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof covering any type pattern in roofing including ridges, hips, valleys and gutters etc.,if required dismantling iron work included and stacking the material within 50 metres lead Land complete all as specified and directed.
Note : Work will be executed at any height. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 106 | SQM | 20 ₹2,120 | 105 ₹11,130 | 25 ₹2,650 | 20 ₹2,120 | 11 ₹1,166 Lowest |
| 2.00 | M & L for precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required Land complete all as specified and directed.
Note : Work will be executed at any height. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 100 | SQM | 700 ₹70,000 Lowest | 990 ₹99,000 | 900 ₹90,000 | 1,000 ₹1,00,000 | 800 ₹80,000 |
| 3.00 | M & L for precoated galvanised steel sheet in Ridges plain (500 - 600mm) roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete all as specified by Engineer-in-charge.
Note : Work will be executed at any height. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 10 | RM | 400 ₹4,000 Lowest | 810 ₹8,100 | 900 ₹9,000 | 920 ₹9,200 | 520 ₹5,200 |
| 4.00 | M & L for Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Confirming to IS 1161-1979 grade St- 240 Land complete all as specified and directed. | 151 | KG | 4 ₹604 Lowest | 120 ₹18,120 | 150 ₹22,650 | 150 ₹22,650 | 110 ₹16,610 |
| 5.00 | M & L for painting to steel surfaces with two coats including preparation of surfaces complete all as specified & directed. | 50 | SQM | 80 ₹4,000 | 60 ₹3,000 Lowest | 100 ₹5,000 | 100 ₹5,000 | 79 ₹3,950 |
| 6.00 | Removing old APP membrane of any thickness and description carefully without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed. | 720 | SQM | 30 ₹21,600 | 5 ₹3,600 Lowest | 25 ₹18,000 | 100 ₹72,000 | 11 ₹7,920 |
| 7.00 | Demolishing cement concrete manually/ by mechanical means as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed. | 41 | CUM | 300 ₹12,300 Lowest | 350 ₹14,350 | 500 ₹20,500 | 500 ₹20,500 | 340 ₹13,940 |
| 8.00 | M & L for cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, including the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Land complete all as specified and directed. | 5 | CUM | 4,500 ₹22,500 Lowest | 7,900 ₹39,500 | 5,000 ₹25,000 | 7,000 ₹35,000 | 7,000 ₹35,000 |
| 9.00 | M & L for waterproofing treatment to sound, moisture free concrete surface. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised or equivelent expandive grout admixture supplied in 225 gm pouch, treatment of construction joints using polymer modified mortar prepared by using Nitobond SBR Latex or equivalent , application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP2 - Non-shrink cementitious grout or equivalent. any undulated surface and pot holes shall be filled with Epoxy mortar to obtain sound/levelled surface. Application of epoxy primer Nitoproof WB Primer or equivalent on sound mother slab surface. Followed by application of two coats of Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating supplied in 25 kg drum coverage of min @ 2.3 kg/m2 to achieve 1.5 mm dry film thickness in two coats placing glass fibric reinforcemnt min 225 gsm between 1st coat and second coats complete including all tools and tackles as per manufacturer’s specifications. Coating shall be having crack bridging of 2 mm, Elongation (ASTMD 412) > Min 500 %, Tensile Strength (ASTM D412) – 2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, Min 80% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 50, Water vapour transmission not more than 1g/m2/hr, Water Permeability (DIN 1048) – Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C
HSE Guidelines: It is recommended to provide adequate general and local exhaust ventilation, provide protection to eye, face, hand and other skin by wearing appropriate gloves, goggles, face shields, respiratory protection etc. as directed in SDS of the product. : Note : work should be executed only through authorised company applicator and company as well as contractor should give written gurantee for 7 years for roof treatment to the department and if any leakage or seepage during gurantee period. contractor as well as company are responsible for the same and rectified without no extra cost Land complete all as specified and directed. | 720 | SQM | 1,050 ₹7,56,000 Lowest | 1,160 ₹8,35,200 | 1,250 ₹9,00,000 | 1,500 ₹10,80,000 | 1,100 ₹7,92,000 |
| 10.00 | Supplying and laying seperation & protection layer- Geotextile membrane 200 gsm prior to protection screed Land complete all as specified and directed. | 720 | SQM | 60 ₹43,200 Lowest | 150 ₹1,08,000 | 120 ₹86,400 | 200 ₹1,44,000 | 110 ₹79,200 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Aug 2026, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE
GE I R AND D GIRINAGAR PUNE
REPAIRS TO ROOF TREATMENT AND RECTIFICATION OF SEEPAGE LEAKAGE AND CERTAIN ALLIED WORKS IN CERTAIN BUILDINGS AT R AND DE E DIGHI PUNE 15
2026_MES_778950_1
GE I R AND D GNR TOKEN 18 OF 2026-27(8001)
Open Tender
Civil Works
Item Rate
180 days
GE I R AND D GIRINAGAR PUNE
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE
₹50,000
20 Aug 2026
16 Jul 2026
15 Aug 2026
16 Jul 2026
13 Aug 2026
30 Jul 2026
16 Jul 2026 - 23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling G.S. Sheet plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof covering any type pattern in roofing including ridges, hips, valleys and gutters etc.,if required dismantling iron work included and stacking the material within 50 metres lead Land complete all as specified and directed.
Note : Work will be executed at any height. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 106 | SQM | - | - |
| 2 | M & L for precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required Land complete all as specified and directed.
Note : Work will be executed at any height. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 100 | SQM | - | - |
| 3 | M & L for precoated galvanised steel sheet in Ridges plain (500 - 600mm) roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete all as specified by Engineer-in-charge.
Note : Work will be executed at any height. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 10 | RM | - | - |
| 4 | M & L for Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Confirming to IS 1161-1979 grade St- 240 Land complete all as specified and directed. | 151 | KG | - | - |
| 5 | M & L for painting to steel surfaces with two coats including preparation of surfaces complete all as specified & directed. | 50 | SQM | - | - |
| 6 | Removing old APP membrane of any thickness and description carefully without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed. | 720 | SQM | - | - |
| 7 | Demolishing cement concrete manually/ by mechanical means as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed. | 41 | CUM | - | - |
| 8 | M & L for cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, including the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Land complete all as specified and directed. | 5 | CUM | - | - |
| 9 | M & L for waterproofing treatment to sound, moisture free concrete surface. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised or equivelent expandive grout admixture supplied in 225 gm pouch, treatment of construction joints using polymer modified mortar prepared by using Nitobond SBR Latex or equivalent , application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP2 - Non-shrink cementitious grout or equivalent. any undulated surface and pot holes shall be filled with Epoxy mortar to obtain sound/levelled surface. Application of epoxy primer Nitoproof WB Primer or equivalent on sound mother slab surface. Followed by application of two coats of Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating supplied in 25 kg drum coverage of min @ 2.3 kg/m2 to achieve 1.5 mm dry film thickness in two coats placing glass fibric reinforcemnt min 225 gsm between 1st coat and second coats complete including all tools and tackles as per manufacturer’s specifications. Coating shall be having crack bridging of 2 mm, Elongation (ASTMD 412) > Min 500 %, Tensile Strength (ASTM D412) – 2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, Min 80% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 50, Water vapour transmission not more than 1g/m2/hr, Water Permeability (DIN 1048) – Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C
HSE Guidelines: It is recommended to provide adequate general and local exhaust ventilation, provide protection to eye, face, hand and other skin by wearing appropriate gloves, goggles, face shields, respiratory protection etc. as directed in SDS of the product. : Note : work should be executed only through authorised company applicator and company as well as contractor should give written gurantee for 7 years for roof treatment to the department and if any leakage or seepage during gurantee period. contractor as well as company are responsible for the same and rectified without no extra cost Land complete all as specified and directed. | 720 | SQM | - | - |
| 10 | Supplying and laying seperation & protection layer- Geotextile membrane 200 gsm prior to protection screed Land complete all as specified and directed. | 720 | SQM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.70 MB
BOQ_872464.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .