Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹42.2 L+₹2.8 L (7.21%)Admitted-Finance CAMP OFFICE RANGE ROAD CHANDIPUR BALASORE ODISHA 756025 | BALASORE | BALASORE | ODISHA | 756025 | L2 | Admitted-Finance | |
| 3 | L3₹42.3 L+₹3.0 L (7.56%)Admitted-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Admitted-Finance | |
| 4 | L4₹42.8 L+₹3.4 L (8.71%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹42.8 L+₹3.5 L (8.80%)Admitted-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KRISHNA ENTERPRISES L3 | ELECTRO COMMERCIAL CO L6 | chauhan syndicate L4 | Sagar Electricals L5 | ALLIANCE L7 | Rekha Enterprises L1 | M/S RAJENDRA PRASAD L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting the transformer indoor /out door from HT / LT side at site dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strip and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5 mm thick rubberised cork sheet gasket for tank top cover and replacement of gaskets/oil seal of HT/LT side to arrest the leakage of transformer oil complete reassembling the complete dismantled items, reconnecting the HT/ LT supply cable ends at the site for the following transformer complete all as directed by Engineer-in-charge.: (a)Transformer capacity 125 KVA to 250 KVA | 1 | Each | 6,222 ₹6,222 | 6,122 ₹6,122 | 4,450 ₹4,450 Lowest | 6,950 ₹6,950 | 7,100 ₹7,100 | 6,500 ₹6,500 | 6,700 ₹6,700 |
| 1.01 | All as per item No 1 above but Transformer of capacity 300KVA to 400 KVA | 1 | Each | 5,699 ₹5,699 | 6,665 ₹6,665 | 4,600 ₹4,600 Lowest | 7,250 ₹7,250 | 6,566 ₹6,566 | 6,500 ₹6,500 | 6,500 ₹6,500 |
| 1.02 | All as per item No 1 above but Transformer of capacity 500KVA to 630 KVA | 1 | Each | 6,555 ₹6,555 | 6,889 ₹6,889 | 4,850 ₹4,850 Lowest | 7,520 ₹7,520 | 6,355 ₹6,355 | 7,000 ₹7,000 | 7,500 ₹7,500 |
| 2.00 | M&L for lightning arresters suitable voltage 11000 volts expulsion type complete with all fittings, transmission class,discharge capacity 65 kilo amp ncluding installation testing and commissoning as per site requirement complete all as specified and directed by Engr-in-charge . | 1 | Each set | 13,336 ₹13,336 | 13,699 ₹13,699 | 12,450 ₹12,450 | 12,450 ₹12,450 | 12,655 ₹12,655 | 12,000 ₹12,000 Lowest | 13,500 ₹13,500 |
| 3.00 | Supply and Fixing Microprocessor Numerical 3-Over Current & 1Earth fault Protection Relay with high Set Instantaneous unit with in-built Trip Circuit Supervision Type - ADR141C including necessary connection, initial calibration and testing complete all as directed by Engineer-in-Charge. | 1 | Each | 36,665 ₹36,665 | 30,255 ₹30,255 Lowest | 39,600 ₹39,600 | 41,600 ₹41,600 | 35,545 ₹35,545 | 38,500 ₹38,500 | 42,000 ₹42,000 |
| 4.00 | M&L for Filtration and Dehydration of transformer oil of Transformers / OCBs / Oil switches at different location of ITR Chandipur with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete as specified and all as directed by engineer in charge.
Note- The quoted rate is deemed to be included cost of centrifuging the transformer oil by means of electrical operated centrifuging machine .
(ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process and submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose and quoted rate is deemed to be included for this account .
(iii) Old unserviceable oil obtained if any shall be deposited in the MES store complete all as directed by Engr- in- Charge . | 980 | Litre | 29 ₹28,420 | 25.3 ₹24,794 Lowest | 28 ₹27,440 | 27.22 ₹26,675.6 | 28 ₹27,440 | 27 ₹26,460 | 31 ₹30,380 |
| 5.00 | Supply only insulation oil in Transformer Oil tank having Di-electric strength not less than 60 KV at 2.5 mm electrode gap for 60 sec confirming to IS-335 and ISI marked all as spsecified and directed by Engineer-in-Charge. | 1,150 | Litre | 288 ₹3,31,200 | 125 ₹1,43,750 Lowest | 248 ₹2,85,200 | 297 ₹3,41,550 | 300 ₹3,45,000 | 255 ₹2,93,250 | 295 ₹3,39,250 |
| 6.00 | Supply and filling in repair/replacement of silica gel in existing breather assembly complete all as directed by Engineer-in-charge. | 6 | Per Kg | 1,222 ₹7,332 | 1,223 ₹7,338 | 980 ₹5,880 | 1,050 ₹6,300 | 1,125 ₹6,750 | 900 ₹5,400 Lowest | 920 ₹5,520 |
| 7.00 | Supply & fixing in repair/replacement of breather for 400/500 KVA Transformer complete all as directed by Engineer-in-charge. | 5 | Each | 2,666 ₹13,330 | 2,899 ₹14,495 | 2,600 ₹13,000 | 2,545 ₹12,725 | 2,788 ₹13,940 | 2,500 ₹12,500 Lowest | 4,000 ₹20,000 |
| 8.00 | Supply & fixing in repair/replacement of breather for 200/250 KVA Transformer | 4 | Each | 2,998 ₹11,992 | 3,112 ₹12,448 | 2,500 ₹10,000 | 2,480 ₹9,920 Lowest | 3,000 ₹12,000 | 3,000 ₹12,000 | 3,900 ₹15,600 |
Tender Value
Refer Docs
EMD Value
₹79,600
Closing Date
3 Sept 2026, 6:00 pmClosed
Garrison Engineer
GE (I) R and D Chandipur, Post-Chandipur, PIN-756025
REPAIR / REPLACEMENT OF HT CABLE NETWORK, DISTRIBUTION TRANSFORMERS, VCBs OVERHEAD HT STRUCTURES AND EARTHING AT PXE TECH AND RESIDENTIAL AREA AT PXE CHANDIPUR
2026_MES_784302_1
8316/A
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandipur
As per NIT
9 documents required · 9 mandatory
₹500
GE (I) R and Chandipur
₹79,600
Yes
23 Sept 2026
13 Aug 2026
10 Sept 2026
13 Aug 2026
3 Sept 2026
27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting the transformer indoor /out door from HT / LT side at site dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strip and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5 mm thick rubberised cork sheet gasket for tank top cover and replacement of gaskets/oil seal of HT/LT side to arrest the leakage of transformer oil complete reassembling the complete dismantled items, reconnecting the HT/ LT supply cable ends at the site for the following transformer complete all as directed by Engineer-in-charge.: (a)Transformer capacity 125 KVA to 250 KVA | 1 | Each | - | - |
| 1.01 | All as per item No 1 above but Transformer of capacity 300KVA to 400 KVA | 1 | Each | - | - |
| 1.02 | All as per item No 1 above but Transformer of capacity 500KVA to 630 KVA | 1 | Each | - | - |
| 2 | M&L for lightning arresters suitable voltage 11000 volts expulsion type complete with all fittings, transmission class,discharge capacity 65 kilo amp ncluding installation testing and commissoning as per site requirement complete all as specified and directed by Engr-in-charge . | 1 | Each set | - | - |
| 3 | Supply and Fixing Microprocessor Numerical 3-Over Current & 1Earth fault Protection Relay with high Set Instantaneous unit with in-built Trip Circuit Supervision Type - ADR141C including necessary connection, initial calibration and testing complete all as directed by Engineer-in-Charge. | 1 | Each | - | - |
| 4 | M&L for Filtration and Dehydration of transformer oil of Transformers / OCBs / Oil switches at different location of ITR Chandipur with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete as specified and all as directed by engineer in charge.
Note- The quoted rate is deemed to be included cost of centrifuging the transformer oil by means of electrical operated centrifuging machine .
(ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process and submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose and quoted rate is deemed to be included for this account .
(iii) Old unserviceable oil obtained if any shall be deposited in the MES store complete all as directed by Engr- in- Charge . | 980 | Litre | - | - |
| 5 | Supply only insulation oil in Transformer Oil tank having Di-electric strength not less than 60 KV at 2.5 mm electrode gap for 60 sec confirming to IS-335 and ISI marked all as spsecified and directed by Engineer-in-Charge. | 1,150 | Litre | - | - |
| 6 | Supply and filling in repair/replacement of silica gel in existing breather assembly complete all as directed by Engineer-in-charge. | 6 | Per Kg | - | - |
| 7 | Supply & fixing in repair/replacement of breather for 400/500 KVA Transformer complete all as directed by Engineer-in-charge. | 5 | Each | - | - |
| 8 | Supply & fixing in repair/replacement of breather for 200/250 KVA Transformer | 4 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
Sch_8316A.pdf
Additional Documents • 0.25 MB
Tender_Documents_8316A.pdf
Tender Documents • 0.86 MB
BOQ_878775.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .