| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹2.5 L+₹4,471.89 (1.80%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance That the Bid is not L1 | |
| 3 | L3₹2.8 L+₹29,703.89 (12.0%)Rejected-Finance 90 1 287 1 ADARSHA PARA PURBA BIDHYADHARPUR SHYAMNAGAR NORTH 24 PGS PIN 743127 | SHYAMNAGAR | NORTH 24 PARGANAS | WEST BENGAL | 743127 | L3 | Rejected-Finance That the Bid is not L1 | |
| 4 | L4₹2.8 L+₹29,751.89 (12.0%)Rejected-Finance 6201 M G ROAD KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L4 | Rejected-Finance That the Bid is not L1 | |
| 5 | L5₹2.8 L+₹29,781.89 (12.0%)Rejected-Finance | L5 | Rejected-Finance That the Bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹5,567
Closing Date
20 Aug 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, KMC Electrical Sub-Division
OFFICE OF THE ASISTANT ENGINEER Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
SITC of Concealed Split type AC machine and related Electrical work in Junior Faculty room at SSB 7th Floor to be used as Urology MCH final examination room under Medical College and Hospital, Kolkata. Electrical Work
2024_WBPWD_713303_1
WBPWD/AE/KMCESD/NIQ-34/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,567
16 Apr 2025
12 Jul 2024
22 Aug 2024
19 Jul 2024
20 Aug 2024
19 Jul 2024
Amount
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Polycab / Havells/Glostar/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. vide pg no E-14 item no. 1a a) 2 X 4 sqmm + 1 x 2.5 sqmm ( for AC starter, timer)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. vide pg no F-5 item no. 9 a) 4.0 sqmm
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/L & T -Entice/Wipro- NOWA/ABB Ivie) & necy. Connections..Vide page no E-17, Item no 5 b
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/L & T -Entice/Wipro- NOWA/ABB Ivie), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply and installation of 1-Phase timer in double door SPN DB (2+10) way providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box should be painted by powder coated paint. a) 25A DP MCB -1 No. (b)Analog time switch LT240 VAC Base/DIN Mounting cat no-- J648B1 - 1 No. (c) 2- pole single power contactor 250V, 25A coil (Legrand, cat no-- 4125-44) - 1 No. (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- L & T /ABB)
Supply & fixing 250V control starter type OLP 30M, 11-21A range, starter with AC looad display (make-- ultratech/Electron) incl S&F 6 module modular box on wall with nut bolts etc as required.
Supply & delivery 2.0 TR capacity, R407/410 concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Make : Hitachi / O-General / Daikin/ Mitshubishi Heavy Industries)
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split / NORMAL SPLIT AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finolex / Havell's/ RR kable/ Polycab/ Mescab)
Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC (make-- Supreme/ Finolex)
Supplying, fabrication & fixing 3Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making platform for installation of outdoor unit of 2TR concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2Nos. horizontal angle of 25 mm x 25 mm x 5 mm of 1m. length incl. S&F of safety cage made of angle (25X25X5mm) and flat (25X5mm) iron with necessary painting incl. shade arrangement with corogated PVC shade with proper clamping arrangement
S & installation of rectangular type M.S frame of size 10’’ x 6’’ x10’’ of 25mm M.S flat with 02 no interconnections by 25" x 25" x 5" M.S.flat with 25x25x5mm M.S angle with suitable clamping arrangement as required. All angle are jointed by argon welding system. M.S bar gap at 2’’ distance. Whole structure are grouted on wall at each 18" gap with 3" M.S. flat leg splitted at end ( 4" bullet fastener are to be used where grouting will not be possible) and mending good the damage to original finish incl all necy. materials, tools and tackles incl charges of scaffolding and painting with 02 coat of Synthetic enamelled paint over 02 coat of R.O. primer (Asian/Shalimer/Berger) incl. welding, carriage and transportation.
S & installation of removable hanging type rectangular GI tray made of 24 SWG GI Sheet of necessary size below indoor unit for condenced water collection including drainage arrangement. The tray should be hanged with the AC indoor unit with proper removable type clamping arrangement for maintenance of AC indoor unit and painting with 02 coat of Synthetic enamelled paint over 02 coat of R.O. primer (Asian/Shalimer/Berger) for MS part only incl. welding, carriage and transportation.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
STANDARD BUILDERS
MANTHU ELECTRICALS
SUMAN ENTERPRISE
NANABABA ENGINEERING COMPANY
technical_1565564.pdf
PDF • 0.21 MB
techsummary_1565564.pdf
PDF • 0.21 MB
finance_1565564.pdf
PDF • 0.21 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1565564.pdf
PDF • 0.30 MB
ANo.133.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .