| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹19.1 L+₹1.3 L (7.23%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹20.5 L+₹2.6 L (14.8%)Rejected-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC OK | |
| 4 | L4₹21.9 L+₹4.1 L (22.7%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-AOC OK | |
| 5 | L5₹23.8 L+₹6.0 L (33.7%)Rejected-AOC VILLAGE CHANNI POST OFFICE SATTANI DISTT UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC OK |
| Sl No | Description | Qty | Unit | K S BUILDERS L1 | M/S BHARAT LIGHT ELECRIC.CO L6 | MAMTA ENTERPRISES L4 | KARAN TRADERS L2 | PARAS RAM ASGOTRA AND SONS L5 | M/SHansrajbuilder L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.0 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 cm girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming/outgoing electric connections by using required size copper lugs/thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of FRLS PVC insulated and PVC Conduit of Size 20mm shall be measured and paid as one unit length.
“Make: Havells / Finolex /Polycab /Grandlay Cables”
Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad. | 1,000 | Rm | 156 ₹1,56,000 | 230 ₹2,30,000 | 300 ₹3,00,000 | 80 ₹80,000 Lowest | 100 ₹1,00,000 | 210 ₹2,10,000 |
| 2.00 | All as per item No 01 here in before but 2 run of 4 sqmm and one run of 2.50 Sqmm earth contuinity conductor complete all as directed. | 200 | Rm | 136 ₹27,200 | 160 ₹32,000 | 230 ₹46,000 | 45 ₹9,000 Lowest | 90 ₹18,000 | 160 ₹32,000 |
| 3.00 | All as per item No 01 here in before but 2 run of 10 sqmm and one run of 6.0 Sqmm earth contuinity conductor complete all as directed. | 50 | Rm | 196 ₹9,800 | 340 ₹17,000 | 450 ₹22,500 | 150 ₹7,500 | 120 ₹6,000 Lowest | 260 ₹13,000 |
| 4.00 | All as per Item No-01 above but 2 single core 1.5 Sq mm,one single core 1.0 sq mm for earth continuity conductor complete all as directed by Enginer-in-charge . | 250 | Rm | 56 ₹14,000 | 70 ₹17,500 | 110 ₹27,500 | 30 ₹7,500 Lowest | 45 ₹11,250 | 48 ₹12,000 |
| 5.00 | Taking down old unserviceable LED Bulk head/Post top lantern light/ security light/flood light fittings/highbay light any wattage and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface all as directed. | 200 | Each | 6 ₹1,200 | 100 ₹20,000 | 10 ₹2,000 | 10 ₹2,000 | 50 ₹10,000 | 2 ₹400 Lowest |
| 6.00 | Supply and fixing Flood light 80 W Toughened glass with secondary lens optics, Graphite grey powder coated matt finished pressure diecast aluminium housing designed to act as heat sink for efficient dissipation of heat, & luminous flux 9600 LM, CTT 5665+355K, CRI>70, 50000 Burning hrs, Built-in-Surge protection 4KV, External Surge Protection 10Kv, Ingress Protection IP66, Impact ProtectionIK07, Beam Angle (+10%) 60 degree, with complete all electric connection as specified and directed.”
Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad. | 20 | Each | 3,206 ₹64,120 | 3,500 ₹70,000 | 3,200 ₹64,000 | 3,000 ₹60,000 Lowest | 4,295 ₹85,900 | 3,200 ₹64,000 |
| 7.00 | “Supply and fixing of post type 40 watt, luminous flux 4000 Im, CCT 5665 + 355K, CRI>70, 50000 Burning hrs, Built –in-surge protection 4 KV, External surge protection 10KV, Ingress protection IP65, Impact protection IK06, Diffuser: PC opal for LED section & PC clear for housing, Spun aluminium black powder coated housing with PDC bottom etc with complete all electric connection as specified and directed.”
Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad. | 40 | Each | 2,906 ₹1,16,240 Lowest | 8,500 ₹3,40,000 | 4,000 ₹1,60,000 | 3,850 ₹1,54,000 | 6,000 ₹2,40,000 | 4,200 ₹1,68,000 |
| 8.00 | “Supply and fixing Led Bollard 9W, anti-glare UV Stabilized PC diffuser, Pre-wired with potted constant current integrated LED driver, Luminous flux 765 IM, CCT 3000k, CRI>70, 50000 Burning hrs, Built-in-surge protection 4 KV, Ingress Protection IP 65, Impact protection IK06, Relaxed white well-lit, with reduced glare having opal PC duffuer, constant current electronic driver provided with high voltage, open & short circuit protection, with complete all electric connection as specified and directed.”
Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad. | 20 | Each | 1,796 ₹35,920 Lowest | 2,000 ₹40,000 | 2,300 ₹46,000 | 1,800 ₹36,000 | 6,000 ₹1,20,000 | 2,600 ₹52,000 |
| 9.00 | “Supply and fixing Highbay 80W, PC modular lens, Pressure die –cast aluminum housing, Luminous flux 10400 Im, CCT 5665+355K, CRI>70, 50000 Burning hrs, Built-in-Surge protection 4KV, External Surge Protection 10kV, Ingress Protection IP66, Impact protection IK08 with complete all electric connection as specified and directed.”
Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad. | 5 | Each | 3,206 ₹16,030 Lowest | 3,500 ₹17,500 | 3,600 ₹18,000 | 4,000 ₹20,000 | 5,000 ₹25,000 | 5,000 ₹25,000 |
| 10.00 | “Security Light 35 W, Epoxy powder coated pressure die-cast aluminum housing, Weather proof gaskets provided for LEDs and control gear compartments, LEDs are provided with non-yellowing modular secondary lens optics, luminous flux 4550 Lm, CCT 5665+355K, CRI>70, 50000 Burning hrs, built-in-Surge protection 4KV, External Surge Protection 10Kv, Ingress protection IP66, Impact protection IK08 complete all as specified and directed.
Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad. | 40 | Each | 1,496 ₹59,840 | 1,500 ₹60,000 | 1,399 ₹55,960 Lowest | 1,500 ₹60,000 | 1,600 ₹64,000 | 1,600 ₹64,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 May 2025, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR REPLACEMENT OF OLD UNSV MCB DBS SUB MAIN WIRING SECURITY LIGHT FITTINGS SERVICE CABLES EARTHING AND CONNECTED WORKS TO VARIOUS OTM AND MD ACCN AT JINDRAH UNDER GE ARMY DHAR ROAD
2025_MES_704792_1
8071/NIT-10/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹60,000
Yes
12 Aug 2025
19 Apr 2025
21 May 2025
20 Apr 2025
19 May 2025
5 May 2025
Amount
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.0 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 cm girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming/outgoing electric connections by using required size copper lugs/thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of FRLS PVC insulated and PVC Conduit of Size 20mm shall be measured and paid as one unit length. “Make: Havells / Finolex /Polycab /Grandlay Cables” Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
All as per item No 01 here in before but 2 run of 4 sqmm and one run of 2.50 Sqmm earth contuinity conductor complete all as directed.
All as per item No 01 here in before but 2 run of 10 sqmm and one run of 6.0 Sqmm earth contuinity conductor complete all as directed.
All as per Item No-01 above but 2 single core 1.5 Sq mm,one single core 1.0 sq mm for earth continuity conductor complete all as directed by Enginer-in-charge .
Taking down old unserviceable LED Bulk head/Post top lantern light/ security light/flood light fittings/highbay light any wattage and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface all as directed.
Supply and fixing Flood light 80 W Toughened glass with secondary lens optics, Graphite grey powder coated matt finished pressure diecast aluminium housing designed to act as heat sink for efficient dissipation of heat, & luminous flux 9600 LM, CTT 5665+355K, CRI>70, 50000 Burning hrs, Built-in-Surge protection 4KV, External Surge Protection 10Kv, Ingress Protection IP66, Impact ProtectionIK07, Beam Angle (+10%) 60 degree, with complete all electric connection as specified and directed.” Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
“Supply and fixing of post type 40 watt, luminous flux 4000 Im, CCT 5665 + 355K, CRI>70, 50000 Burning hrs, Built –in-surge protection 4 KV, External surge protection 10KV, Ingress protection IP65, Impact protection IK06, Diffuser: PC opal for LED section & PC clear for housing, Spun aluminium black powder coated housing with PDC bottom etc with complete all electric connection as specified and directed.” Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
“Supply and fixing Led Bollard 9W, anti-glare UV Stabilized PC diffuser, Pre-wired with potted constant current integrated LED driver, Luminous flux 765 IM, CCT 3000k, CRI>70, 50000 Burning hrs, Built-in-surge protection 4 KV, Ingress Protection IP 65, Impact protection IK06, Relaxed white well-lit, with reduced glare having opal PC duffuer, constant current electronic driver provided with high voltage, open & short circuit protection, with complete all electric connection as specified and directed.” Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
“Supply and fixing Highbay 80W, PC modular lens, Pressure die –cast aluminum housing, Luminous flux 10400 Im, CCT 5665+355K, CRI>70, 50000 Burning hrs, Built-in-Surge protection 4KV, External Surge Protection 10kV, Ingress Protection IP66, Impact protection IK08 with complete all electric connection as specified and directed.” Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
“Security Light 35 W, Epoxy powder coated pressure die-cast aluminum housing, Weather proof gaskets provided for LEDs and control gear compartments, LEDs are provided with non-yellowing modular secondary lens optics, luminous flux 4550 Lm, CCT 5665+355K, CRI>70, 50000 Burning hrs, built-in-Surge protection 4KV, External Surge Protection 10Kv, Ingress protection IP66, Impact protection IK08 complete all as specified and directed. Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
Supply and fix in replacement of security light fitting bracket made up of 25/32 mm dia medium grade pipe of length 0.9 mtr with bending in shape by hot or cold method with 2 nos 50x4 mm MS flate clamps with nut bolts and washer etc all as directed
“Supply and fixing of Bulk Head 10 W , graphite grey (RAL7024) powder coated pressure die-cast aluminium alloy, Pre-wired upto terminal block, Luminous flux 1000LM, CCT 5665+355K, CRI>80, 50000 Burning hrs, built-in-Surge protection 4KV, External Surge Protection 10Kv, Ingress protection IP65, Impact protection IK08 complete all as specified and directed”. Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
Taking down MCB DB vertical/TPN 4 way /SPN, Meter box of any size and disposal under schedule of credit and making good disturbed surfaces all as specified and directed.
Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as directed.
All as per item No: 14 here in before but SPN 12 way, 240 volts complete all as directed.
All as per item No: 14 here in before but TPN 04 way, 415 volts complete all as directed.
Supply and fixing of MCCB Incomer distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating surface mounting, TPN 4 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB complete all as specified and directed.Note : The cost of removing old MCB box and making good of surface as original i.e. brick work, plastering, white washing etc is included in quated rate.
Supply and fixing in replacement of MCCB 3 Pole .415 V. fixed type, 100 Amps with breaking capacity 16 KA, including spreader terminals / thimble of suitable size and making connections complete all as specified and directed.
S & F of isolator DP 63 Amp 230 Volt complete all as specified and directed.
All as per item No: 19 here in before but isolator TPN 63 Amps, 415 volts complete all as directed.
S & F of isolator SP, 6-40 Amps, 230 Volts complete all as specified and directed.
Supply and fixing of MCCB 3 Pole .415 V. fixed type,125Amps with breaking capacity 16 KA and making connections of incoming and out going wires are properly fitted in suitable lugs/thimples including taking out old unserviceable MCCB complete all as specified and directed.
Supply and fixing in replacement of MCCB 3 Pole .415 V. fixed type, 63 Amps with breaking capacity 16 KA, including spreader terminals / thimble of suitable size including taking out old unserviceable MCCB complete all as specified and directed.
M&L in replacement of fabrication of sheet metal enclouser to accommodate 04 Nos electric meters of size 800 mm x 500 mm x 150 mm deep and 1.6 mm thick MS sheet, powder coated, bakelite sheet with side hung shutter including provision of locking arrangement and niche covered with 4 mm thick plain glass , including locking arrangement & open Wiring coverd with Flexible PVC Pipe of suitable size complete all as specified and as directed.
Supply & fixing of Busbar chamber 200 Amps, TPN 8 way minimum length 460mm long enclosed in sheet metal enclosure including all the fixing arrangements,angle iron legs -04 No's made out of 50mmx50mmx6 mm thick MS angle mounted on plateform of PCC foundation making all incoming and out going connections through the lugs/thimbles including taking out old unserviceable complete all as specified and directed.
Supply and fixing of On load Change over switch, 4 Pole,415 Volts,50 Hz,AC,200 Amps side handle operated conforms to IS 60947-1 & 3 incl making all incoming and out going wires are properly fitted through lugs/thimbles including taking out old unserviceable complete all as specified and directed.
Supply and fixing of Switch disconnector fuze 200 Amps , 3 Pole & Neutral ,AC,415 Volts,50 Hz with Panel mounting cubical type in sheet steel Encl, with 3 No's HBC fuses incl making all incoming and out going wires are properly fitted through lugs/thimbles including taking out old unserviceable complete all as specified and directed.
Supply and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminiumconductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as directed.
All as per item No 28 above but 16 sqmm 2 core omplete all as directed
Material and labour for road / path way any type (Concrete) cutting , including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed.
Meterial and labour for cement concrete in foundations for pole or any other work type C2 1:3:6 with 40 mm gradedcrushed stone aggregate all as directed
Meterial and labour for cement concrete in foundations for pole coping or any other work type B1 1:2:4 with 20mm graded crushed stone aggregate all as directed
Meterial and labour for cement concrete in foundations for pole or any other work type D2 1:4:8 with 40 mm graded crushed stone aggregate all as directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been errected and tested , all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
M & L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engr-in-Charge
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
M&L for Galvanised iron pipe light grade 40mm bore with fittings for fixing of LED Post top lantern light fitting 40 Watts(Gate light) including taking down old unserviceable complete all as specified and directed.
Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 63 mm outer dia and 50 mm inner dia incl taking out old unserviceable complete all as directed.
Taking out defective/unserviceable XLPE UG of size 16 sqmm 2 core to 35sqmm 4 core from roads/trenches required at site complete all as directed by Engr-in- Charge.
Supply, laying , jointing ,testing and commisioning LT underground cable 1100 volts grade XLPE insulated and steel strip or wire armoured heavy duty with multistranded aluminium conductor 16 Sqm 4 core size complete all as specified and directed. (for Block) Note:- (i) Excavation and earth work cable protection and sand cushioning shall be measured and paid seperately. “Make: Havells /Polycab /Grandlay Cables ” Note: Product authentication and warranty to be provided by the local representative of the concerned company on OEM letter head pad.
All as per item No: 42 here inbefore but size 25 sqmm 4 core
All as per item No: 42 here inbefore but size 35 sqmm 4 core
All as per item No: 42 here inbefore but size 16 sqmm 2 core
Dismantling /taking out old unsv earthing incl M& L Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth lead wire and protection pipe beyond 7.5m shall be measured and paid separately.
Supply and fixing in replacement of GI Pipe medium grade 80 mm bore inclusive of all fittings such as tees bends, elbows, reducer, bell mouth tube ends and all fixing accessories such as couplers hook, nuts, saddlers, pipe hook etc (8.0 meter long) complete with GI base plate, finial taper plug, bolts, nuts & screws etc including making the holes on the pole (bottom and top) suitable size for drawing of wire 1.5 sqmm 3 core round flexible for connection of security light fitting from junction box to light fittings including of one primer coat, one under coat and one finishing coat of silver paint including dismantling/taking out old unserviceale one all as specified and directed.
Deduct Schedule of Credit of Rs. (-) 77120.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
KARAN TRADERS (BID ID -3295313)
M/SHansrajbuilder (BID ID -3294749)
MAMTA ENTERPRISES (BID ID -3300392)
PARAS RAM ASGOTRA AND SONS (BID ID -3295019)
M/S BHARAT LIGHT ELECRIC.CO (BID ID -3300135)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .