| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC L1 OK | |
| 2 | L2₹16.1 L+₹1.7 L (11.7%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹16.5 L+₹2.0 L (14.2%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹24.4 L+₹10.0 L (68.9%)Rejected-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-AOC OK |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
HQ CWE (AF) BHISIANA
REPAIR MAINTENANCE COOLING APPLIANCES AT AF STATION BHISIANA
2022_MES_531451_1
CWE(BHI)/BHI-18/2022-23
Open Tender
Civil Works
Item Rate
270 days
AF Bhisiana
AS PER COVER 1
6 documents required · 6 mandatory
₹500
GE AF Bhisiana
₹60,000
Yes
26 Aug 2022
16 Jun 2022
29 Jul 2022
16 Jun 2022
27 Jul 2022
8 Jul 2022
16 Jun 2022 - 23 Jun 2022
Amount
S&F in replacement of , pen-type expansion tank 800 x 800 x 800mm for Cold/Hot water for Installation, Testingof MS construction made of 6 mm thick mild steel sheet duly insulated with XLPE insulation applied by adhesive conforming to standard specifications and finally applying 0.63 mm thick aluminium sheet cladding complete with type3, gradel roofing felt strip (as per IS:1322 as amended up to date) at joints and repairing of damage to building etc. as required complete in all respects with connection over flow and drain 40 mm dia. Make up tank (500 Itr.) with make up connection with float valve, drain valve and Incoming line valves, vent connections, valves and fittings as required. Loc Auditorium, complete all as specified and directed.
Supply & fixing in replacement of Duct insulation at various AC Plant at AF stn , 50 mm thick resin bonded glass wool insulation wrapped in Hussan cloth based vapor barrier and chicken wire mesh wrapped on insulation and finally covered with plaster of pairs 10 mm thick etc complete all as specified and directed by Engineer-in-Charge ( 3001& Auditorium).
S&F in replacement of ladder wall supported steel ladder 12 feet long made of SS 304 material heavy grade 50 mm dia pipe with arrangement of 50 mm hand rails dia 40 mm stainless stell non slip steps provided with electrical earthing connection and anchoring fixture with FRP coated 3 mm thick for avoid to rusting from chemical action, complete all as specified and directed. Note : The rate shall be included welding work and PCC work required to fixing of ladder.
S&F wall supported steel ladder 25 feet long made of SS 304 material heavy grade 50 mm dia pipe with arrangement of 500 mm hand rails dia 40 mm stainless stell non slip steps provided and anchoring fixture with FRP coated 3 mm thick in various AC pants building for avoid to rusting from chemical action. Note : The rate shall be included welding work and PCC work required to fixing of ladder, complete all as specified and directed.
Supply, fixing of powder-coated extruded aluminium rectangular diffusers complete with black anodized extruded aluminium VCD (wherever specified), nuts, bolts, screws etc. as per approved drawings and as required Supply air diffusers of required sizes with volume control damper, complete all as specified and directed.
S&F in Replacement of display unit with card having numerical control system for package type AC plant at bravo and CRC including blower unit ,condensor unit,compressor ON/OF and start/stop & settimg push button all as specified and directed by Engineer-in-Charge.
S&F in Replacement of Air filter suitbale suitable for 1.5 ton splitAC as per sample in Engr-in-charge office, complete all as specified and directed.
S&F in Replacement of over load protector suitable for window type /Split AC 1.5 ton capcity, complete all as specified and directed.
S&F in Replacement of with new PVC drain pipe with clamps set of size 40 mm dia up to 2 mtrs, complete all as specified and directed.
S&F in Replacement of with new PVC drain pipe with clamps set of size 20 mm dia up to 2 mtrs, complete all as specified and directed.
M&L for fabrication of outer shell cover for windopw type air conditioning of 1.5 TR capacity and including preperation of surface and applying with two coats of synthetic enamel pait over one coat of primer by spray painting, complete all as specified and directed.
S&F in Replacement of power contactor suitable for 1.5/2 ton cap split type AC of any make /model all as specified and directed by Engr-in-charge.
S&F in Replacement of copper cappliary tube suitable for window /split type AC's water coolers/Refrigerator, complete all as specified and directed.
Dismantling/taking down window type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and cleaning of Air filter Nylon and reinstalling AC in the same Location and made air tight to opening with thermacol material all around the window type AC complete and testing on full load etc complete all as specified and as directed.
S&F in Replacement of starting relay assembly including cover and clips for air conditioner window type 1.5/2 Ton capacity fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F starting capacitor 100/120 mfd suitable for 1.5/2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F in Replacement of running capacitor 40/45/50/55/60 36/45 mfd suitable for 1.5/.2 Ton capacity of window /split type AC fixed in replacement complete all as specified and as directed by Engineer-in-charge. BAJAJ/SIEMENS/SHARHA/ASIAN
S&F in Replacement of capacitor 6 mfd suitable for blower motor,fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F in Replacement of Remote suitable for split/window AC any make/type all as specified and directed by engr-in-charge
S&F in Replacement of sealed compressor of cap 1.5 TR of window type AC and replacement with manufactures reconditioned compressor company make hermatic sealed Receprocating compressor of cap 1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same, complete all as specified and directed.
All as above Item No 22 but capcaity 2TR
S&F in Replacement of sealed compressor of cap 1.5 TR of window type AC and replacement with manufactures reconditioned compressor company make Rotary compressor factory sealed compressor of cap 1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same, complete all as specified and directed.
All as above Item No 24 but capcaity 2TR
S&F in replacement fan blade for window/split ACof 1.5/2.0 TR all as specified and directed by engr-in-charge.
S&F in Replacement of pvc insulated 1100v grade of size 2.5 sqmm, 4 core pvc round sheathed insulated flexible round/or flate FR copper cable, complete all as specified and directed.
S&F Metal Clad Plug Top and Socket’ 15 Amps 3 pin fixed in replacement complete all as specfied and directed.
S&F in Replacement of single pole and neutral enclosure with, two pin and earth plug and socket 240 volts complete with one MCB 20/25 Amps including taking down existing all as specified and directed by Engineer-in-Charge.
S&F in Replacement of in Replacement of Evaporator coil assembly complete suitable for window type AC of capacity 1.5/ 2.0 TR etc complete and recharging the refrigerant R-22R32/ 407 / 410 A and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
S&F in Replacement of Condensing coil (Copper coil) assembly complete suitable for window type AC of capacity 1.5 /2TR on etc complete and recharging the refrigerant R-22/R32/407/410A and testing fixed in replacement complete all as specified and directed.
S&F in Replacement of Front grill assembly complete suitable for window type AC of capacity 1.5/ 2.0 Ton fixed in replacement complete all as specified and as directed.
M&L for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32/R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the window/Split type AC of capacity 1.5/ 2.0 Ton including installation at site and testing on full load complete all as specified and as directed by Engineer-in-charge.
M&L in Replacement of rewinding of blower motor of window type AC 1.5/2TR capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engineer-in-charge.
S&F in Replacement of Blower blade suitable for blower motor of window type AC of capacity 1.5/ 2.0 TR Ton fixed in replacement complete all as specified and as directed by Engineer-in-charge.
M&L for repair to voltage stabilizer of capacity 04/05 KVA single phase including replacement of circuit plate, starting relay, voltmeter, fuse terminal box with fuse carrier, rewinding the main transformer with copper wire of existing size and repair / replacement time delay relay (1-2 Min) built-in type designed for low cut off 140/160 volt, high cut off 260/280 volt on single phase, 50 cycle AC supply etc complete all as specified and as directed by Engineer-in-charge
S&F in Replacement of sealed compressor of cap 1.50 TR of Split type AC factory sealed manufactures compressor receprocating compressor of cap 2/1.50 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same, complete all as specified and directed.
All as above Item No 37 but capcaity 2TR
S&F in Replacement of Rotary compressor of cap 1.5 TR of Split type AC in new rotary compressor of cap 2/1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut& bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same, complete all as specified and directed.
All as above Item No 39 but capcaity 2TR
Supply & fill Refrigerant (R -22/R32) suitable for window /Split AC. Note: Empty cylinder will not be issued by the department, complete all as specified and directed.
Supply & Fill Refrigerant (R -134a/410A) suitable for split/window AC. Note: Empty cylinder will not be issued by the department, complete all as specified and directed.
S&F in Replacement of Insulation to refrigerant pipes of split ACs any make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc, complete all as specified and directed.
S&F in Replacement of thermostat suitable for split/window AC any capacity all as specified and directed by engr-in-charge
S&F in replacement Oscilation motor with swing blade strip for indoor unit of split AC 1.5/2.0 TR capacity same specification /make as per existing one complete all as specified and directed.
M &L for dismantling/taking down of existing Split type AC of cap 2.0/1.5 TR complete with Indoor/Outdoor unit from existing location from 09 mtr height with all Electric Connection and all refrigerant Pipes and matching the existing disturbed surface area, Including Refixing/Re-Installation of Split type AC Shifted to new location on suitable wall places complete all as specified and directed by Engr in Charge. (Refrigerant Recharging gas, Insulation of Copper tubes, copper tubes paid & measured seprate under respective item)
S&F in Replacement of Copper Pipe Line of size 1/4" to 1/2" for Split/Window type AC of any capacity complete all as specified and directed by engr in charge.
S&F in Replacement of Copper Pipe Line of size 3/8'' to 5/8" for Split/Window type AC of any capacity complete all as specified and directed by engr in charge.
S&F in Replacement of brass suction valve of 5/8" suitable for cassette /split type, complete all as specified and directed.
S&F in Replacement of brass suction valveof 1/2" suitable for cassette /split type, complete all as specified and directed.
S&F in Replacement of brass discharge valve valve 3/8" suitable for cassette /split type, complete all as specified and directed.
S&F in Replacement of brass discharge valve 1/4" suitable for /split type, complete all as specified and directed.
S&F in Replacement of Brass flair nuts 1/2'' to1/4'' for Split/Window type AC of any capacity complete all as specified and directed.
S&F in Replacement of Brass flair nuts 3/8'' to 5/8'' for Split/Window type AC of any capacity complete all as specified and directed.
M&L for dismantling /Taking down of Window type AC 2/1.5 TR Cap and cutting of holes in bricks wall from existing at new location carefully with all electric connection and connecting the same in new location and including the window opening filled with the brick masonary and cement plastering to match the existing disturbed surface area complete all as specified and directed by Engr in Charge.
S&F in Replacement of Fan motor for Outdoor unit, of same specification as per existing one suitable for Split type AC of capacity 1.5/2 Ton fixed in replacement complete all as specified and directed
S&F in Replacement of Evaporator coil assembly complete suitable for Split type AC of capacity 1.5/ 2.0 TR Ton etc complete and recharging the refrigerant R-22/R32/407/410A and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
S&F in Replacement of Condensing coil assembly complete suitable for Split type AC of capacity 1.5 /2 TR Ton etc complete and recharging the refrigerant R-22/R32/407/410A and testing fixed in replacement complete all as specified and directed by Engineer-in-charge.
S&F in Replacement of Connection lead 3 core PVC sheathed copper flexible cable of size 4 sqmm complete with necessary thimbles etc , fixed in replacement , complete all as specified and as directed by Engineer-in-charge.
S&F Blower motor for Indoor unit,same specification as per existing one suitable for Split type AC of capacity 1.5/2.0 Ton fixed in replacement complete all as specified and directed
M&L in Replacement of rewinding of out door / blower Fan motor of Split /window type AC 1.5 Ton capacity single phase with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engineer-in-charge.
M & L for Submain wiring with two single core of 4 Sqmm and one single core of 4 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface. Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit.Make of cable : Plaza, Polycab, Finolex.
M & L for Submain wiring with two single core of 6 Sqmm and one single core of 6.0sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing Surface.Note: 3 run of 6 sqmm & one run of PVC conduit shall be measured as single unit.Make of cable : Plaza, Polycab, Finolex.
S&F in Replacement of for fixing of duel capacitor suitable for both window/split AC all as specified and directed by engr-in-charge
Supply and fix in replacement complete PCB with Remote control for Indoor unit of Split type AC cap. 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features of mode slection, timer, temperature control or as per existing specification and model complete all as specified and directed.
Supply and fix in replacement complete PCB with Remote control for Outdoor unit of Split type AC cap. 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features of mode slection, timer, temperature control or as per existing specification and model complete all as specified and directed.
S&F in replacement of flexible type water drain out pipe suitable for indoor unit of split AC as per existing type /model complete all as specified and directed.
Attending day to day complaint of detecting the fault in Refrigerator/Water cooler/ Window AC/Split /Voltage stabilizer/ Electric supply in all eqpt like loose nut and bolts,leakage of tube,checking electrical connections,charging of refrigerant, fan motor,compressor fault etc all as specified and directed.Note:- Any defective part which are required to be replaced to make functional ACs shall me measured and paid seperately. The contractor should attend the complaint and rectify the defect within 02 days (Maximum) failing which RS @500 per day per AC (split / window 1.5 / 2TR ) /water cooler / Refrigerator will be recovered from the RAR/Final bill.
S&F in replacement of Blower drum assembly indoor unit complete for Split AC of 1.5/2.0 ton as per existing all as specified and as directed.
S&F in replacement LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton window/split AC with auto/manual facility at site all as specified & directed.
S&F in replacement of magnetic door with lining and providing new magnetic door with lining suitable for refrigerator of 165/ 300 iltres capacity of any make and model
M & L for complete maintenance and repairs of refrigerator of capacity 165 to 310 ltrs including servicing cleaning of refrigerator internal portion checking of compressor, condenser and replacement of overload relay, thermostat, capacitor, wiring,veg tray,chiller tray,strainer,freezer door and timer etc and testing complete all as directed. Notes of Item No. 1 to 4) do not paid separately. (i) Rates includes servicing of unit for one time and will be considered as one job. (ii) Rates are including for Spares required for replacement which is mentioned in servicing item no. (1 to 4) do not paid separately. (iii) Servicing shall be carried out in the presence of Engr-in-Charge or his representative. Necessary service report(complaint slip) is to be signed by the rep. of AGE E/M. (iv) Old spare parts retrived after replacement will be the property of the cotractor under schedule of credit and shall be removed by the contractor outside at his own cost.
S&F in replacement of compressor sealed unit of refrigerator from existing refrigerator by removing suction/ discharge line and providing new approved factory sealed compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134/R22/407A including connection suction/ discharge line complete. 165 to 310Ltrs capacity refrigerator, complete all as specified and directed.
S&F in replacement of Thermostat switch with defrosting system suitable for refrigerator of capacity 165 to310 Ltrs fixed in repairs complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Starting relay assembly suitable for refrigerator of capacity 165 to 310 Ltr fixed in repairs complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Plastic ice tray suitable for refrigerator of capacity of existing make and model 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Vegetable tray with suitable glass cover suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-charge.
Supply and fix Lamp assembly including lamp suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed.
S&F in replacement of Aluminum freezer suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed.
S&F in replacement of Plastic chowki of superior quality suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Water cooler tray 80/40,80/120 ltr and supply and fix new water waste tary stainless steel material including nut bilt, wahser , gas welding work etcin existing water cooler all as specified and directed.
S&F in replacement of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below and flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 R22 or as existing including connection suction/ discharge line complete. 150/120Ltrs capacity water cooler all as specified and as directed by Engr-in-charge
S&F in replacement of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of existing capacity given below and flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 R22 or as existing including connection suction/ discharge line complete. all as specified and as directed by Engr-in-charge, 40/80/60Ltrs capacity water cooler
S&F in replacement of condensor coil and providing new condensor coil of same size and quality for water cooler capacity upto 150 LPH.all as specified and as directed by Engr-in-charge
S&F in replacement of over load protector suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler Make : Shriram/Ranutrol all as specified and as directed by Engr-in-charge
S&F in replacement of fan motor capacitor suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler all as specified and as directed by Engr-in-charge
S&F in replacement of running capacitir suitable forof 40/80/60/120/150 ltr cap of water cooler Make : Shriram/Ranutrol all as specified and as directed by Engr-in-charge
S&F in replacement of starting relay for water cooler cap 40/80/60/120/150 ltrs all as specified and as directed by Engr-in-charge
S&F in replacement of wiring kit for water cooler 2.5/4 sqmm copper wire full set including clips all as specified and as directed by Engr-in-charge
S&F in replacement of fan motor blade for water cooler cap 40/80/60/120/150 ltrs all as specified and as directed by Engr-in-charge
S&F in replacement of insulation with fiber glass 15 mm thick for water cooler of any cpacity all as specified and as directed by Engr-in-charge
S&F in replacement of push cock of brass chromium plated suitable for water cooler any make/model Make Prayaj/Jaquor all as specified and as directed by Engr-in-charge
S&F in replacement of float valve with all accessories of 15 mm (PVC) suitbale for any capacity of water coolers all as specified and as directed by Engr-in-charge
S&F in replacement of fan motor and providing new fan motor of existing quality and characteristics suitable to any make of water cooler type capacity 1/8 HP.all as specified and as directed by Engr-in-charge
S&F in replacement of MCB SP 5-20 Amps capacity having breaking capacity 10 KA 'B' curve Make Legrand/Schneider/Siemens all as specified and as directed by Engr-in-charge
S&F in replacement of temp sensor with cold assembly 230 v AC suitbale for splittype/cassetter ac of 1.5/2 Ton cap of make RANUTROL/DANFOSS/INDFOSS, all as specified and as directed by Engr-in-charge
Aman Enterprises
M/s Vee Kay Associates
M/s Luxmi Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .