Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC 111 MINI SHOPPING COMPLEX NEAR HOTEL ASIA NEHRU MARKET JAMMU JAMMU KASHMIR 180004 UDYAM JK 07 0001057 | JAMMU | JAMMU AND KASHMIR | 180004 | ₹2.2 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.2 LRejected-AOC JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹2.2 L | L2 | Rejected-AOC NOT THE LOWEST BIDDER |
| 3 | L3₹2.3 LRejected-AOC JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹2.3 L | L3 | Rejected-AOC NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Vaibhav Engineers and Technocrates L2 | M/S MUSKAN ELECTRICAL L3 | AADISHWAR ELECTRICAL AND MECHANICAL WORKS L1 |
|---|---|---|---|---|---|---|
| 1.01 | A) Providing and fitting new parts in place of damaged Parts of motor feeder panel of unit no 3 installed at Tawi Pump House Jammu. Checking of Motor feeder panel. Racking out VCB trolly from the chamber, extracting old damaged/electrically stressed/defective parts of Vacuum circuit Breaker, cleaning chamber from inside using air blower, cleaning all the terminals using CRC spray. Providing and fitting of new Shunt trip coil 110 V DC-01 No, closing coil-110 V DC 01 no, Anti pumping relay -01 No, Gear motor (spring charging Motor 350 rpm, 160 Watt, 230 V AC) -01 No., Drive mechanism-01 no., Breaker auxiliary switch-01 No in place of damaged one. Applying Lubricants to mechanical linkages for smooth operation, resetting/ adjustment of vacuum interrupter for proper gap between fixed and moving contacts, checking continuity of all the phases between fixed and moving contact of all the phases, checking IR Value across phases and between phase and earth using meggar. Tightening all the terminals properly, checking all control wiring and replacing if any wire seems worn out/ electrical stressed by P/F new wire with terminals, maintaining proper color code and using ferrule for proper identification, checking working of charging and release mechanism. Inserting vacuum interrupter in the compartment. Providing and fitting new Bi-Metallic Overload relay (1.4-2.3 A) for protection of Gear Motor-01 No, TNC switch-01 No., Under Voltage relay -01 No., Bridge Rectifier Unit With Diode 10 A, 600PIV Input voltage -110 v AC, Output Voltage-110 V DC- 01 No. in place of damaged ones, replacing all the damaged fuses and indicators with new one.Testing to ensure electrically and Manually charging, closing and tripping of breaker.
B) Providing and fitting new components in place of old damaged parts of HT motor feeder panel 800 Amp (6.6 KV, 25 kA) of unit No 6 installed at Tawi Pump House by way rack out Breaker from Enclosure. Job involves Extraction of old damaged parts, cleaning chamber from inside using air blower, cotton cloth, cleaning all the terminals using CRC spray. Providing and fitting of Andrew Yule /Equivalent make new spares such as Shunt trip coil 110 V DC-01 No, closing coil-110 V DC 01 no, spring charging Motor 350 rpm, 160 Watt, 230 V AC -01 No., Catch mechanism-01 No., Breaker axillary switch-01 No., Auxiliary contactor (110 V DC) -01 no in place of damaged one. Applying Lubricants to mechanical linkages for smooth operation resetting/ adjustment of vacuum interrupter for proper gap between fixed and moving contacts, checking continuity of all the phases also checking IR value between fixed and moving contact of all the phases, across phases and between phase and earth using meggar. Tightening all the terminals properly, checking all control wiring and replacing if any wire seems worn out/ electrical stressed P/F new wire with terminal, maintaining proper color code and using ferrule for proper identification, checking working of charging and release mechanism. Inserting vacuum interrupter in the compartment. P/Fitting of tripping relay 110 V DC- 1 No. Replacing damaged indicators, Fuses carrier/link. Complete job includes cost of material, fitting and testing charges. (Above rates are inclusive of all taxes as applicable) | 1 | C. Job | 2,20,000 ₹2.2 L | 2,25,000 ₹2.3 L | 2,17,000 ₹2.2 L |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
28 Oct 2025, 3:00 pmClosed
Executive Engineer Mech Div. RTIC Jammu
Office of Executive Engineer Mech Div. RTIC Jammu
P/F of new components by way of replacement of old damaged/worn out components i.e., relays, vacuum interrupter, spring charging motor mechanism, catch mechanism, control wiring along with HRC fuses, other equipment of 02 Nos. HT panel
2025_IFC_291082_1
E-NIT 26 of 2025-26 DTD 07.10.2025
Open Tender
Electrical and Maintenance Works
21 days
Office of Executive Engineer Mech Div. RTIC Jammu
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
Yes
Executive Engineer Mech Div. RTIC Jammu
₹4,500
Yes
Office of Executive Engineer Mech Div. RTIC Jammu
13 Dec 2025
7 Oct 2025
29 Oct 2025
7 Oct 2025
28 Oct 2025
9 Oct 2025
8 Oct 2025
Amount
A) Providing and fitting new parts in place of damaged Parts of motor feeder panel of unit no 3 installed at Tawi Pump House Jammu. Checking of Motor feeder panel. Racking out VCB trolly from the chamber, extracting old damaged/electrically stressed/defective parts of Vacuum circuit Breaker, cleaning chamber from inside using air blower, cleaning all the terminals using CRC spray. Providing and fitting of new Shunt trip coil 110 V DC-01 No, closing coil-110 V DC 01 no, Anti pumping relay -01 No, Gear motor (spring charging Motor 350 rpm, 160 Watt, 230 V AC) -01 No., Drive mechanism-01 no., Breaker auxiliary switch-01 No in place of damaged one. Applying Lubricants to mechanical linkages for smooth operation, resetting/ adjustment of vacuum interrupter for proper gap between fixed and moving contacts, checking continuity of all the phases between fixed and moving contact of all the phases, checking IR Value across phases and between phase and earth using meggar. Tightening all the terminals properly, checking all control wiring and replacing if any wire seems worn out/ electrical stressed by P/F new wire with terminals, maintaining proper color code and using ferrule for proper identification, checking working of charging and release mechanism. Inserting vacuum interrupter in the compartment. Providing and fitting new Bi-Metallic Overload relay (1.4-2.3 A) for protection of Gear Motor-01 No, TNC switch-01 No., Under Voltage relay -01 No., Bridge Rectifier Unit With Diode 10 A, 600PIV Input voltage -110 v AC, Output Voltage-110 V DC- 01 No. in place of damaged ones, replacing all the damaged fuses and indicators with new one.Testing to ensure electrically and Manually charging, closing and tripping of breaker. B) Providing and fitting new components in place of old damaged parts of HT motor feeder panel 800 Amp (6.6 KV, 25 kA) of unit No 6 installed at Tawi Pump House by way rack out Breaker from Enclosure. Job involves Extraction of old damaged parts, cleaning chamber from inside using air blower, cotton cloth, cleaning all the terminals using CRC spray. Providing and fitting of Andrew Yule /Equivalent make new spares such as Shunt trip coil 110 V DC-01 No, closing coil-110 V DC 01 no, spring charging Motor 350 rpm, 160 Watt, 230 V AC -01 No., Catch mechanism-01 No., Breaker axillary switch-01 No., Auxiliary contactor (110 V DC) -01 no in place of damaged one. Applying Lubricants to mechanical linkages for smooth operation resetting/ adjustment of vacuum interrupter for proper gap between fixed and moving contacts, checking continuity of all the phases also checking IR value between fixed and moving contact of all the phases, across phases and between phase and earth using meggar. Tightening all the terminals properly, checking all control wiring and replacing if any wire seems worn out/ electrical stressed P/F new wire with terminal, maintaining proper color code and using ferrule for proper identification, checking working of charging and release mechanism. Inserting vacuum interrupter in the compartment. P/Fitting of tripping relay 110 V DC- 1 No. Replacing damaged indicators, Fuses carrier/link. Complete job includes cost of material, fitting and testing charges. (Above rates are inclusive of all taxes as applicable)
Vaibhav Engineers and Technocrates (BID ID -2619734)
M/S MUSKAN ELECTRICAL (BID ID -2620354)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
2.pdf
Tender Documents • 0.37 MB
BOQ_935473.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid