Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹14.1 L Quoted ₹14.3 L | L1 | Accepted-AOC ACCEPTED BEING L1 |
| 2 | L2₹14.3 LRejected-AOC | ₹14.3 L | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| 3 | L3₹14.5 LRejected-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | ₹14.5 L | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| 4 | L4₹14.8 LRejected-AOC | ₹14.8 L | L4 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| 5 | L5₹15.8 LRejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | ₹15.8 L | L5 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| Sl No | Description | Qty | Unit | Green Ray Technologies L2 | rc enterprises L6 | PSK Enterprises L1 | OM Muruga Enterprises L4 | ANAND ENTERPRISES L3 | SIVA ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate (iii) The cost deemed to inclued taking down old LT panel. | 3 | Each | 2,05,000 ₹6.2 L | 2,16,000 ₹6.5 L | 2,06,000 ₹6.2 L | 2,15,000 ₹6.5 L | 2,14,500 ₹6.4 L | 2,25,000 ₹6.8 L |
| 1.01(a) MCCB 4P 320 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) | |||||||||
| 1.02(b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 6 No (Outgoing) | |||||||||
| 1.03(c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc | |||||||||
| 1.04(d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | |||||||||
| 2.00 | Supply, Install, Testing and commissioning LT distribution board (Outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3mm thick CRCA steel sheet with suitable size of bus bar and cable chamber weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, complete in all respect all as specified & directed by Engineer-in-charge comprising of following items :- .
Note - (i) Panel shall be placed on PCC plateform of size and design recommended by manufacturer and the cost of the same shall be deemed to be included in unit quoted rate (iii) The cost deemed to inclued taking down old LT panel. | 1 | Each | 1,59,000 ₹1.6 L | 1,76,000 ₹1.8 L | 1,65,500 ₹1.7 L | 1,62,000 ₹1.6 L | 1,52,100 ₹1.5 L | 1,71,000 ₹1.7 L |
| 2.01(a) MCCB 4P 200 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer) | |||||||||
| 2.02(b) MCCB 3P 63 Amps, 25 KA, 415 V, 50 Hz - 6 No (Outgoing) | |||||||||
| 2.03(c) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc | |||||||||
| 2.04(d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three | |||||||||
Updated dates
Tender Value
₹15.8 L
EMD Value
₹31,600
Closing Date
2 Apr 2026, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIR AND MAINTENANCE OF LT PANELS AND CONNECTED ITEMS IN CERTAIN AREAS UNDER GE MAINT ARAKKONAM
2026_MES_754718_1
8560E8
Open Tender
Electrical and Maintenance Works
120 days
Garrison Engineer M NAS Arakkonam
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹31,600
Yes
20 May 2026
5 Mar 2026
4 Apr 2026
5 Mar 2026
2 Apr 2026
19 Mar 2026
(a) MCCB 4P 320 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)
(b) MCCB 3P 125 Amps, 36 KA, 415 V, 50 Hz - 6 No (Outgoing)
(d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three
(a) MCCB 4P 200 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)
(b) MCCB 3P 63 Amps, 25 KA, 415 V, 50 Hz - 6 No (Outgoing)
(d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three
(a) MCCB 4P 200 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)
(b) MCCB 3P 80 Amps, 25 KA, 415 V, 50 Hz - 6 No (Outgoing)
(d) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three
(a) MCCB 4P 320 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)
(b) MCCB 3P 160 Amps, 25 KA, 415 V, 50 Hz - 5 No (Outgoing)
(c) MCCB 3P 63 Amps, 25 KA, 415 V, 50 Hz - 3 No (Outgoing)
(e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three
Supply and fix for MCCB 3 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 125 Amps with breaking capacity 16 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable.
Supply and fix for MCCB 3 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 160 Amps with breaking capacity 16 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable.
Supply and fix for MCCB 3 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 63 Amps with breaking capacity 16 KA complete all as specified and as directed by Engr-in-charge.Make: Legrand/ Siemens/Scheneider/ABB Note : Including taking down old unserviceable.
Supply and lay pipe galvanised iron tubing light grade of 100 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_845906.xls
BOQ • 0.23 MB
Tenderdocuments8560.pdf
Tender Documents • 0.66 MB
Scheduleofcredit8560.pdf
Additional Documents • 0.19 MB
SummaryPage8560.pdf
Additional Documents • 0.08 MB
NIT8560.pdf
Additional Documents • 0.37 MB
Download all tender documents and submit your bid