Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.5 LAccepted-AOC | 1 | Accepted-AOC being lowest | |
| 2 | 2₹8.8 L+₹94,318.80 (12.0%)Rejected-Finance | 2 | Rejected-Finance being not lowest | |
| 3 | 3₹9.0 L+₹1.1 L (14.7%)Rejected-Finance | 3 | Rejected-Finance being not lowest | |
| 4 | 4₹9.5 L+₹1.6 L (20.9%)Rejected-Finance | 4 | Rejected-Finance being not lowest |
Tender Value
₹9.8 L
EMD Value
₹19,700
Closing Date
20 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF JAIPUR
AGE I AF JAIPUR
REPAIR/REPLACEMENT AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT AF STATION JAIPUR
2024_MES_646686_1
8462/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I AF JAIPUR
Class E and above and category b (I)
8 documents required · 8 mandatory
₹500
AGE I AF JAIPUR
₹19,700
30 Aug 2024
18 Mar 2024
25 Apr 2024
18 Mar 2024
20 Apr 2024
4 Apr 2024
Amount
Dehydration/Filteration of tranformer/Stabilizer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV with 2.5 mm gap complete all as specified and as directed.
(a) Oil topping up shall be measured and paid seperately.
(b) Contractor has to make his own arrangement for oil filteration plant.
M & L for topping up/change oil for transformer of 11KV/433 Volt of different capacity of dielectric strength /repturing capacity of oil not less than 50 KV (tested at site with testing kit with 2.5 mm gap ) and test the the dielectric strength of transformer oil before and after the topping up and make oil to the required level of transformer indicator level all as specified and directed by EIC. Make: Power/Savita or as approved by GE.
(a) The transformer oil shall be ISI marked and brought at site in sealed container only.
(b) Item included M & L for necessary T & P for collection of transformerr oil samples , testing kit and filteration plant.
S & F in replacement breather for transformer oil conservator tank including filled with silica gel for transformer of 400 KVA complete all as specified and as directed by engineer-in charge.
M & L for painting of steel surface of LT steel tubular pole 8/9 mtr including accessories like cross arms and clamps etc painted with two coats of aluminium paint over and including one coat of red oxide primer over the prepared surface including numbering of poles with black colour paint complete all as specified and directed.
M & L for Maintenance/Over hauling of HT VCB 11 KV of any Make and rating at AF station Domestic and Tropo Area Jaipur by taking shunt down with prior intimation and cleaning of HT VCB by using air blower , tightning the control circuit , Checking the all fuses , to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper all as directed by Engineer -In - Charge. Note: Quoted Rate is deemed to be included the following:-
(i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unseviceble indicator lamps asper colour code allas specified and as directedby Engineer - In - Charge.
(ii) Rack out /Down the HT VCB kept in Test position , Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the servicebility of earthing connection by Earth megger note down the readings.
Taking out/down u/s LT UG cable of any size from trenches/pipe/ducts/ pole complete all as specified and directed.
M&L for LT under ground cable having size 10 sq mm 4.0 core 1100 V grade XLPE insulated screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductors laid in pipes, trenches/ducts fixed on pole etc complete all as specified and directed.
Description all as per Item Ser No. 7.00 here-in-before but having size size 16 sq mm 4 core.
Description all as per Item Ser No. 7.00 here-in-before but having size 25 sq mm 4 core.
Description all as per Item Ser No. 7.00 here-in-before but having size 50 sq mm 3.5 core.
Description all as per Item Ser No. 7.00 here-in-before but having size 120 sq mm 3.5 core.
Excavation in trenches not exc 1.5 mtrs wide & not exc 1.5 mtrs in depth for taking out/laying of pipes/cables etc & getting out in soft/loose soil complete all as specified and directed .
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed .
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size Outer dia 50 mm and inner dia 38mm of pipe with all fittings laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified. (Excavation and earth work shall be measured and paid separately).
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 100mm thick PCC (1:3:6) type C-2, using 40mm graded aggregates as in sub base complete all as specified and directed.
Supply and spreading fine aggregate (sand) for sand cusioning to receive interlocking tile complete all as specified and directed all as specified and directed by Engineer-in-Charge.
M&L for refixing machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed by Engineer-in-Charge.
M&L machine pressed precast coloured Interlocking paver block / tiles any shape and size 60 mm thick confirming to IS- 15658-2006 of M-35 grade chemically treated rubber moulded complete all as specified and directed all as specified and directed by Engineer-in-Charge.
M&L chequered cement concrete tiles 20cm x 20cm x 25mm thick, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
LAKSHMI ASSOCIATES
L BHIMSEN
shree shyam enterpises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .