Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.5 L+₹92,260 (2.74%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹37.3 L+₹3.6 L (10.8%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹40.6 L+₹7.0 L (20.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹44.8 L+₹11.2 L (33.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹47.1 L
EMD Value
₹94,200
Closing Date
3 Mar 2022, 6:00 pmClosed
GE NORTH DELHI CANTT-10
GE NORTH DELHI CANTT-10
REPAIR MAINT OF EXTERNAL WATER SUPPLY SYSTEM INCLUDING REPLACEMENT OF PIPE LINES VALVES REPAIRS TO VARIOUS MOTORS PUMP SETS CLEANING OF UG SUMPS AND CONNECTED MISC EM WORKS OF AMAR VIHAR DGQA AREA AT ANAND PARBAT AND REPAIR MAINT OF INTERNAL ELECTR
2022_MES_505798_1
GE/NORTH-55/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT-10
₹94,200
Yes
30 Mar 2022
4 Feb 2022
5 Mar 2022
4 Feb 2022
3 Mar 2022
18 Feb 2022
Amount
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed.
All as per item No.01 but Hard/dense soil.
All as per item No.01 but Soft/disintegrated rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply and laying galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends,elbow,tees,short pieces,connectors,caps,plugs and unions,etc) and fixing complete with clips,wall hookswooden plugs,or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:- (Note:- 1. laying of pipe line on wall/floors/terrace of high raise buildings up to the 8 th floor by using with suitable clamps, jointing material and necessary accessories and T&P complete necessary arrangement like scaffolding to carry out the work 2. Earthwork shall be measured and paid separately under relevant items).
100 mm dia
80 mm dia (Continoue item No 6 here in before)
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
Supply and fixing gunmetal gate valve screwed down high pressure with iron wheel head ,screwed both ends for iron pipe including taking out unserviceable valve for the following sizes:-
50 mm dia
40 mm dia
25 mm dia
20 mm dia
15 mm dia
Supply and laying in repairs/replacement Mild steel water tubing 6mm thick,as per IS 3589,heavy duty, class C, complete with all fittings (such as bends,elbow,tees,short pieces,connectors,back nuts,diminishing pieces,caps,plugs and unions,etc) and fixing complete with clips,wall hooks,wooden plugs,or laying in walls and ceiling etc.,also cutting,screwing and waste and for making forged bends on piping,welding as required at site complete all as specified directed for the following sizes:-
80 mm dia
100 mm dia
Supply, laying, jointing and testing ductile iron pipe with spigot and socketed ends conforming to IS 8329 with inside cement mortar lining laid in trenches of 150 mm bore incl taking down unsv complete all as specified and directed. Note : Excavation and earth work, fittings and joints shall be measured and paid for seperately.
All as per item No 9 above but 100 mm dia.
Material and labour for DI specials of any size such as tees, bends of any size and radius, tapers, collers, tail pieces, caps and plugs etc incl takinng down unsv complete all as specified.
M&L for Rubber Gasket Joint (Tyton Joint) with jointing material for DI/CI pipe of 100 mm bore incl taking down unsv complete all as specified and directed. (Note: Earth work shall be measured and paid separately)
All as per item No 12 above but 150 mm dia.
M&L in replacement for CI spigot and socket pipe fittings such as bends(any type, radius angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc.,) Tee pieces single branch, Y Junction, double branch, cross (all sockets or socket and spigot collars, caps and plugs of up to 150mm bore incl taking down UNSV fittings all as specified and directed.
M&L for run lead joint including preparation of ends, provision of Hemp/yarn gasket and Pig lead filling and proper caulking for CI/DI pipe of 80 mm bore complete all as specified and directed. (Note: Earth work shall be measured and paid separately)
All as per item No 15 above but 100 mm dia.
M & L for repairs/replacement of cast iron sluice valve of pressure class PN-1.6 type flanged and drilled at both ends, conferming to ISI mark and having gun metal spindle and rings including wheel for operating all as specified including two numbers flanged socket and jointing materials such as bolts, nuts, washers, rubbers/ fibre board gasket complete all as specified and directed for the following dia of bore:-
50 mm dia
80 mm dia
100 mm dia
M & L for repairs/replacement of NRV heavy duty conforming to ISI marked both ends flanged including jointing material such as bolts, nuts, washers, rubbers/ fibre board gasket complete all as specified and directed for the following dia of bore:-
50 mm dia
80 mm dia
100 mm dia
M & L for foot valves strainer, releasing flip type with rubber gasket including necessary fittings, fixtures nuts , bolts and other arrangements incl taking down UNSV valves all as directed at site for the following dia of bore:-
50 mm dia
80 mm dia
100 mm dia
Supply only Calcium hypochlorite 65% to 70% chlorine content in granual form(calcium based granular disinfect for water treatment) packed in 45 kgs each drum.
M&L for chlorine test kit with coloured sample complete with all testing fitment and OT solution in rexine finish box.
M&L for total hardness test (5-1000 mg/L) kit with coloured sample complete with all testing fitment and OT solution in rexine finish box. Make- Aquafit/aquasol
Supply and filling of crystal common salt using for regeneration process in water softner plant complete all as specified and directed.
M&L for bailing out the water from the semi underground/UG sump up to 40,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed.Note:- Rates quoted deemed to be inclusive of T&P and safety equipments required at site.
M&L for wiremesh frame including necessary calmp arrangements for suitable bore of 100/150mm vent pipes for semi UG sumps in all as specified and directed.
M&L for Construction of valve chambers 1200 mmx1200mmx900 mm with 15 cm thick solid concrete block masonary,block casted using PCC 1:3:6 type C-1mix built in cement and sand mortar 1:4,15 mm plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement 15 mm thick,MS sheet cover 3mm thick including 40x40x3 mm MS angle frame embedded in 150 mm thick PCC 1:2:4 type B-1,with 25x6 mm flat iron hold fast,handles,hinges with locking arrangments, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in type of soil including demolition of existing damaged valve chambers & disposal of surplus soil to a distance n.exc.50 m.
All as per item No 26 above but size 90x90x90 cm
Removing UNSV and Material & Labour for cross arms, bracings, supports, clamps, angle iron, flats and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes for making supporters, ladders in water tanks,frames, pump houses including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of black paint over one coat of red oxide primer complete all as directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme all as specified.
S&F for factory made sheet metal enclosure box of size not less than 60cm x45cmx 45 cm for fixing of DOL starters upto 3 HP rating motors any type/model,outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated openable door after dismanteling the existing unsv complete all as specified and directed.
S&F,testing and commissioning high pressure booster pump, RPM 2700, size 25x25 mm, 0.5 HP,1 phase, head range 6-28 mtrs,discharge 2700-450 LPH,capacitor run 10 MFD, 2 pole type complete with fixing necessary PCC foundation,accessories with complete system incl taking down old unsv deposit to store yard complete all as specified and as directed. Make : Kirloskar model star galaxy or equivallent in /Crompton/KSB
Collecting water samples on clean bottle from borewells/UG sumps/service tanks and getting tested for Physical,chemical and bacteriological prameters (as per IS 10500:2012) analysis from approved institutions/lab and submission of results in triplicate complete all as specified and directed.
Comprehensive maintenance inclding preventive and periodical maintenane of Sand Filter Media (Flow rate capacity 35 Cum/Hr - 04 Nos) and Softner Plant (Flow rate capacity 50 Cum/ Hr - 04 Nos) with connected motors, UPVC pipe lines, butterfly valves etc., (Make - Optimus Envirpro Pvt Ltd, Resin -Thermax) or equivalent, installed at Amar Vihar pump house in reliable safe and efficient condition through MOU with OEM by periodically examining, preventive maintenance of plants, pipe lines, valves for trouble free function as per recommendation and attending breakdown/ complaint as and when on required basis, maintenance on regular basis complete with preventive maintenance including replacement of UPVC pipes (different sizes) short lengths upto 5 mtrs, fittings, flanges with nut and bolts, pressure gauges, replacement of required necessary fittings alongwith rectification of defects complete all as specified and directed. [Notes :- (i) The contractor shall carry out routine checking of the complete plants and rectify the any defects noticed immediately (ii) Copy of agreement concluded between contractor & OEM for execution of work thorugh OEM shall be submitted to GE with in 07 days from date of commencement. (iii) Treated water total hardness should be maintained less than 200 mg/l and submit he monthly water test report of Total Hardness (CaCO3) of treated water. (iv) The rates quoted against for this item shall be applicable for enire period of 01 Month. (v) Rates quoted aginst the above mentioned work wise items are required of efficient working of plant are to be included in the job. (vi) If complaints were not rectified within 04 Hrs of intimation, the following penalities will be imposed and deducted from contractors dues :- (a) Rs 1500/- per complaint for not attending the complaint and keeping pendig 04 Hrs to 12 Hrs/ per complaint. (b) Rs 3000/per complaint for not attending the complaint and keeping 12 hrs to 24 hrs/per complaint.
M&L for topup of resin for softner plant complete all as specified and ditected.
Supply and fixing in reapirs of multi port valves/butter fly valves 100mm dia fixing at sand filter and softner plant vessles all as specified and directed.
M & L for Cutting of road/path for laying of pipe line and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified.
S&F in replacement of water pressure gauge with black steel case, copper alloy wetted parts, snap-in- acrylic window with white plastic dial and plastic pointer having 0-20 kg/cm2 pressure range incl taking down UNSV complete all as specified & directed.
S&F in replacement of water pressure gauge with black steel case, copper alloy wetted parts, snap-in- acrylic window with white plastic dial and plastic pointer having 0-14 kg/cm2 pressure range incl taking down UNSV complete all as specified & directed.
M&L for spray Painting of complete Water Pumpset of cap any type up to 20 HP with two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete all as specified and directed.
M & L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled paint of approved shade all as specified.
Supply only spares suitable for sluice valve of size 50/80 mm dia
Spindle SS
Check nut gunmetal.
Gland ring with packing
T nut and bolts
Supply only spares suitable for sluice valve of size 100/150 mm dia
Spindle SS
Check nut gunmetal.
Gland ring with packing
T nut and bolts
S&F in repairs for informatory/eqpt history sign boards of size not less than 900 x 600 mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame, back ground and epqt history with high intensity prismatic reflective tape as specified colours (blue and white) complete all as specified and directed.
M&L for Lifting and lowering of submersible pump and motor set from bore well of any dia after disconnecting electric and water connection of any make and any size capacity under any of chain pulley block or manually appropriate length 70 to 200 Mtr after opening the socket and pipe all as directed.
M&L for flushing&developement of bore well of any capacity and size at the pressure 10 kg/sqcm to 15 kg/sqcm by diesel engine driven air compressor of capacity 620 cfm, depth up to 200 mtrs with using air pipe and connected items to improve the yield of tube well as specified and directed. (Note: 1.Rates included for Transportation of air compressor along with tools and accessories at differenet locations in AOR. 2. Lifting/lowering of borewell shall be measured and paid separately)
M&L for Dismantling carefully submersible motor and taking out motor and removing all burnt wire from the starter after cutting rewinding of motor with PVC insulated finolex make copper conductor water proof suitable for submersible motor of require size but not less than original grinding of rotor and reassembling the rotor and stator and replacement of bearing bush sleeve of rotor painting of motor with approved colour of synthetic enameled paint all as per specified and directed for the following sizes.
Supply only thrust bearing for submersible pump.
Supply only rotor of motor for submersible pumps of the following sizes.
Supply only coupling bush for submersible pump and motor.
Supply only sand guard for any make of pump.
Supply only GM impeller for submersible pump any make of 3 to 7.5 HP capacity.
Supply only gland packing with wire rope 1/4 " 1/2".
Supply only rubber insertion sheet 4mm thick.
S&F in repairs for PVC insulated water proof flat 3 core cable 1100 volt grade submersible with copper conductor stranded of size 4 Sqmm.
S&F in replacement of fully automatic star-delta starter in exist LT Panel with necessary rating contacotrs, OLR for rating 5 to 15 HP any type of motors and pump sets incl with necessary wiring in exist panel complete all as specified and directed. (Make/model- as per sample)
S&F in replacement of fully automatic star-delta starter in exist LT Panel with necessary rating contacotrs, OLR for rating 15 to 30 HP any type of motors and pump sets incl with necessary wiring in exist panel complete all as specified and directed. (Make/model- as per sample)
S&F in replacement 3 pole power contactor for starter with suitable size copper wiring, copper thimbles incl taking down old one complete all as specified and directed of the following capacity.(Makes/Model- as per sample)
S&F in repairs for single phase preventor for 3 phase motors fixed for star delta starters all as directed.(Makes/Model- as per sample)
S&F in replacement Automatic Phase sequence corrector having Capacity 5 -30 HP pump sets, Automatically correct Input supply reverse phase also protections against single phasing voltage unbalancing and low & high voltage within 3 to 5 seconds.(Make/model - as per sample)
S&F in repairs for Thermal OLR suitable current rating for ML 0 to ML 3 contactors with suitable size copper wiring, copper thimbles incl fixed in exist PBs complete all as specified and directed.
Supply and fixing MS tubing heavy duty (Class -C) column pipe, 50 mm bore conforming to IS-1239 coupled with heavy duty suitable size of MS flanges 12mm thick duly welded on both sides as directed including necessary nut and bolts with washers & rubber packing required at site condition and lowered in to the bore well including taking out old unserviceable Column pipe complete all as specified and directed. (Note : - Taking out and lowering of submersible pump set shall be measured and paid under respective item)
M&L for Disconnection electrical and water connection of the centrifugal pump and motor 20/25 HP with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt fixing the require new parts(parts such as shaft, impellor, coupling & bearing shall be supplied under relevant item of schedule ) and complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the following size/ capacity of motors. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
Supply only shaft suitable for 20/25 HP centrifugal pumps for the following sizes.
Supply only GM impellor suitable for 20/25 HP centrifugal pumps for the following sizes.
Supply only MS coupling suitable for 20/25 HP centrifugal pumps for the following sizes.
Supply only bearing suitable for 20/25 HP centrifugal pumps for the following sizes.
M&L for rewinding of electrical motor 20/25 HP with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as Colton top varnish etc of centrifugal pump set motor all as specified and directedfor the following sizes.
M&L for Disconnection electrical and water connection of the induction motor/self priming set/high pressure pumps up to 7.5 HP with base plate and transported to work shop opening carefully and replacement of bushes, winding,gland packing, ball bearing, rubber gasket nut and bolt including two coat of synthetic enameled paint over a coat of red oxide primer,shaft impeller and coupling bearing and complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the following size/ capacity of motors. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, flooring and coping filling and mass concrete with cement plastering finishing all as specified and directed.
Supply and fix air termination, single pointed aluminium rod 12mm dia and 300 mm long, to be fixed with aluminium strip on roof top(up to 8 storey) as reqd at site incl necessary fixing and clamping arrangements with strip complete all as specified and directed.
M&L for test cum bimetalic inspection joint gun metal or phosporous bronze size 75x75x25mm connection piece for jointing down conductor of aluminium strio and GI earth strip and fastednd with nut, bolts and aluminum ends soldered and complete joint housed in MS box of 25cmx30cmx15cm fabricated from 3mm thick steel sheet welded and screwed complete including testing system all as specified and directed.
S&F aluminium strip 25x3.15mm with shaddles and fixing screw etc for and down conductors above ground complete all as specified and directed. (Note:- Fixing of Aluminium strip on wall/floors/terrace of high raise buildings up to the 8 th floor by using with suitable size of shaddles and necessary arrangements of T&P complete for fixing of strip)
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of size 32 X 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) including testing on completion if desired earth resistance is not obtained the earthing will be redone without extra cost complete all as specified and directed.
S & F earth continuity conuctor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole/test point or any other situation for loop earthing etc as required 32x6 mm dia galvanised iron strip all as per specified and directed.
Supply, fixing and testing of water meter 150 mm dia CI body double flange ended type, up to measure 6 digits, class B magnetic type complete incl cutting existing DI/CI line and fixing with necessary fittings reqd at site & earth work complete all as specified and directed.
M&L for replacement fire alaram panel confirm to IS 2189 of 08 zones window type for Manual call box and actuation of hooter in respective floor, sealed maintenance free batteries of 15 AH capacity 24 volts with inbuilt battery charger,operates on 230V, Zone wise isolation facility& fault LED indicators for fire signals, MS cabinet powder coated complete incl taking down unsv complete all as specified and directed.
S&F in repairs for flush mounted 16 gauge MS sheet Manual Call Box with micro switch with transparent hinged vandal resistanat cover in red colour complete.
S&F in repairs for wall mounted speaker(electronic hooter) in acoustically treated box with 4 watt speaker, Colour in Red complete all as specified and directed.
M&L for MS conduits 20mm dia alongwith the accessories in surface/recess and making good the exist wall fixed with saddles with base plate complete all as specified and directed.
M&L for 2 core x1.5 sqmm FRLS unarmoured copper conductor cable incl taking down unsv complete all as specified and directed.
M&L for GI flexible conduit 20mm dia incl taking down unsv complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as per srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F ceiling fan regulator, 2 Module stepped type of 0 to 04 rotary steps, electronic, socket type, humfree, AC, 230 volts, 100 watts complete.
S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete.
S&F in repair 10/12W LED T5 TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair ultra modern recess mounting 36 Watts, 5700K, 2x2 LED flat panel complete with integrated electronic driver, soft-light and glare free symmetrical illumination, suitable for POP ceilings high brightness SMD LEDs, etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
Taking down of existing u/s surface/recessed light fitting and supply & fixing mounting 30/36 Watts in CDL , 4x1 LED flat panel complete with envornmental friendly, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source suitable for ceilings high etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as directed.
S&F in repair energy saving security light fitting of 70 watts LED pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket suitable size in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete
Taking down of existing u/s highbay lights and Supply and fixing in repair energy saving flood light 150 watts LED 5700K die-cast aluminium IP 66 flood light with high power LEDs as light source, comprising with electronic driver and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete.
Supply and fixing ceiling fan 400mm sweep, cubid type with built in LED light and remote control in white/warm white with connections including necessary cutting in ceiling complete all as directed by Engr - in - charge.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4.0 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
All as per item No 104 but with 6 sqmm and 6sqmm as earth wire nominal cross sectional area all specified & directed
All as above but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 10 Sqmm nominal cross sectional area all complete specified & directed
All as as above but for 02x1.5 Sqmm for phase & neutral and 01x 1.5 Sqmm for continuous earth wire
Taking down of existing u/s highbay lights and fixing only LED flood light 100/150 watts and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete all specified & directed
S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all specified & directed
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts,16 KA - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, "C" curve, 10 KA - 12 Nos.
S&F sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 400 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 250 Amps, 03 pole, AC, 415 Volts, 25 KA - 01 No. (b) MCB, SP, AC, 230 volts of 63 Amps, "C" curve, 10 KA - 12 Nos.
S&F in repair MCB, SP, AC, 230 volts of 10 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete all specified & directed
S&F in repair MCB, DP, AC, 230 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete all specified & directed
S&F in repair MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete all specified & directed
S&F Ventilating fan wall mounted type of 250 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed.
S&F in repair MCCB, 100 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
S&F in repair MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all specified & directed
S&F in repair MCCB, 200 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete all specified & directed
S&F in repair MCCB, 250 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete all specified & directed
S&F or passing through pipe, 6 Sqmm, 2 core, 1100 Volts grade, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed service cable twin core flat or circular for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all specified & directed
All as above but 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor complete all specified & directed
Supply and laying cable XLPE insulated screened PVC badded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core incl connection complete all as specified & directed’
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - 98,206.00
Pall Associates
Shiv Enterprises
M/s S.G. BUILDERS
Surjit and Sons
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .