Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹8.5 L
EMD Value
₹8,500
Closing Date
24 Jul 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE COMMISSIONER
Salem City Muncipal Corporation, Fort Main Road, Salem
Providing Painting, Electrical and Plumbing Work for Urban Health Wellness Centre UHWCto the K.P.Karadu in Division No49 of Kondalampatty Wards office
2023_MAWS_339221_1
E3/Est No.318/B/2023-2024
Open Tender
Civil Works
Lump-sum
30 days
SALEM CITY MUNICIPAL CORPORATION
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,500
Yes
24 Jul 2023
8 Jul 2023
24 Jul 2023
8 Jul 2023
24 Jul 2023
8 Jul 2023
Amount
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. (PWD SOR PG.No:65 Item No:268)
Supplying and fixing MS grill to doors windows and ventilators etc. as directed by the departmental officers inclusive of cost of MS grill and labour charges including one coat of red oxide and fixing in position etc. complete
Painting two coats with best synthetic enamel paint of approved Colour for new iron works the rate is inclusive of all materials, brushes and scaffolding charges etc., complete complying with standard specification(paint should be got approved by the Departmental Engineer befor use on work.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got (PWD SOR PG.No:65 Item No:269)
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. (PWD SOR PG.No:66 Item No:270)
Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathedCu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For electronic regulator). (SD-23)
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x l00 x for open PVC plug point.inter locking CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for PVC Plug Point (SD-36)
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point. (SD-39)
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (SD-140)
Supply and fixing of single box type 4'x18w crystal glass LED Tube light with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. (SD-88)
Supply and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1meter down rod on the existing clamp. (SD-107)
Supply and laying of 31/2 x 25 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely (SD-204)
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB solater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make) (SD-179)
Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD-127)
Plain cement concrete 1:2:4 mix (One cement two CS sand and four aggregate) using 20mm size ISS gauge HBBG metal including mixing, laying, consolidating, curing, cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification
Finishing the top with one course of Solar Roof Tiles of Std. size laid in cm 1:3 mix mixed with water proofing compound as per Indian standard 2% by weight of cement used and pointed with the same mortar etc., complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (PWD SSOR Pg No:57 Item No:248)
Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws
Supply and fixing in position of European water closet with 'S' (or) 'P' trap of pproved color and quality with dauble flapped rigid PVC sheet cover the CP brass hinges etc., complete complying with standard specification including supply and fixing in position of 10litre capacity glazed porcelain low level flushing tank on wall including 2 Nos of 15mm & brass nipple, 15mm dia PVC brass connection, 15mm dia GI wheel value, 15mm dia Nylon connection and giving necessary water supply connection etc., complete
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Supplying and fixing in Position P.V.C Specials such as plain bend, door bend, plain tee, door tee, offsetd, y-Junction, plain or with door of various sizes best quality confirming to I.S.S and providing leakproof joints including fixing to wall and giving connection to the P.V.C soil stacks, dismadling the brick masonry or R.C.C floor or Roof Slab and redoing the dismandled portion to original condition etc., complete complying with standard specifications. AS Per IS 4985/2000 and 10124/1982 part II
4" PVC Pipe
4" PVC Elbow
Grating 6"
1"PVC Pipe
1"PVC TEE
1"x1/2" Brass Elbow
1" PVC Elbow
1" PVC Coupler
2.5" PVC Pipe
2.5" Elbow
2in1 Angle Cork
Angle Cork
SS Log Body Tap
4"x3" Reducer
3" PVC Pipe
1.25" PVC Pipe
1.25" PVC Tee
1.25" PVC Coupling
1.25"x1" Reducer
1.25" Valve
1" Vlave
1" Tank Nipple
1.25" Nipple
Supply and planting Grass cover as per plant list to be done over RCC grid pavers with a mix of 50mm thick layers of soil and manure consisting of 1 part of top soil earth, 1 part of river sand and organic manure/compost and grass seed. This mix to be filed uniformly in the gaps of RCC paver grids. The rate includes transportation of plants, loading, unloading at site, manuring, intial watering, cutting, trimming,soil racking, weeding and soil tilting
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .