Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.9 LAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹34.7 L+₹4.9 L (16.3%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
CERTAIN REPAIR TO ELECTRICALLY OPERATED HANGER DOORS IN 50 SQN, T-7 AND T-8 HANGER AT AF STN AGRA.
2021_MES_413108_2
8200-1285/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹62,000
Yes
27 Mar 2021
18 Feb 2021
10 Mar 2021
18 Feb 2021
8 Mar 2021
24 Feb 2021
18 Feb 2021 - 22 Feb 2021
60 days
Amount
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 22 Mtr) including greasing/ oiling for smooth working/operation of gate complete all as specified and directed. Note : (i) Contractor rep shall visit every week and will check and carry out service and repair as required at site. (ii) Payment will be made only once during currency of contract even no of times gate repaired by the contractor. (iii) Parts required for replacement will be measured and paid saperately under respective item of BOQ.
S&F mild steel work such as stopper to guide chanel and other similar items including cutting, welding conforming to E-290 gde-E-165 complete all as specified and directed.
M&L for welding in repairs n exc 2.5cm in length and thickness of metal to be welded not exc 6mm complete all as specified and directed.
S & F of driving units of gate including special geared motors with 4 Nos wheels (pully track), starter , wiring & electrical fitting/fixtures of existing capacity (from starter to motor) complete all as specified and directed. Make : Unidor TM or equivalent and approved by GE.
Repair/maintenance of top track trolly with 8 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of any part & hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. Make : Unidor TM or equivalant & approved by GE.
S&F in repair proxy switches M-30 of existing capacity complete all as specified and directed.
S&F in repair indicator of gate of existing make/size/capacity complete all as specified and directed.
Repair/maint including replacement of defective/wornout parts in control panel of gate including wiring & electrical fitting/fixture (from control panel to starter) complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 12 Mtr) including greasing/oiling for smooth working/operation of gate complete all as specified and directed. Note : (i) Contractor rep shall visit every week and will check and carry out service and repair as required at site (ii) Payment will be made only once during currency of contract even no of times gate repaired by the contractor. (iii) Parts required for replacement will be measured and paid saperately under respective item of BOQ.
Replacement of driving units of gate including special geared motors with 3 Nos wheels (pully track) including starter , wiring & clectrical fitting/fixtures of existing capacity (from starter to motor) complete all as specified and directed. Make : Unidor TM or equivalent and approved by GE
Repair/maintenance of top track trolly with 12 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of any part ie. hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. Make : Unidor TM or equivalant & approved by GE.
Repair/replacement of unserviceable glass relay 24 V ,DC 500 Ohm, 2 C/O-MPC, 240-5 complete all as specified directed.
S&F in repair MCB TPN 63 Amp 240V, C-series 10KA complete all as specified and directed.
S&F in repair MCB SP 6 to 32 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
S&F in repair MCB DP 40-63 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
S&F in repair MCB TPN 32 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
Supply, lay, connecting and testing of XLPE, LT Cable of size 16 Sqmm 4 Core 1100 Volt PVC insulated of flexible cable with ennealed bare copper conductor complete all as specified and directed.
S&F in repair power supply AC to DC 220V/24V complete all as specified and directed.
Supply, lay, connecting and testing of LT Cable of size 2 Sqmm 3 core, 1100 Volt PVC insulated heavy duty flexible cable with ennealed of bare conductor complete all as specified and directed.
S&F controlled wire of size 1 Sqmm multi stranded copper conductor PVC insulated with colour code gray & black complete all as specified and directed.
S&F PVC connector with 4 Amp rating glass fuse NS4. complete all as specified and directed.
S&F in replacement of thermal over load relay of capacity 5 to 12 Amp rating with start & off/ reset version. complete all as specified and directed.
S&F in replacement of cable carrier of existing size complete all as specified and directed.
S&F in replacement of contactor 3 pole 220 Volt upto 16Amp with NC block complete all as specified and directed.
Supply & refilling/ Top up of gear oil in special geared motors all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 15 Mtr) including greasing/oiling for smooth working/operation of each Gate complete all as specified and directed. Note : (i) Contractor rep shall visit every week and will check and carry out service and repair as required at site. (ii) Payment will be made only once during currency of contract even no of times gate repaired by the contractor. (iii) Parts required for replacement will be measured and paid saperately under respective item of BOQ.
M&L for Radium sheet with letters or numbers of any width & height , pasted on 1mm thick galvanised plain sheet of size 1.5mx1.5m with necessary fixing arrengement on hanger doors complete all as specified and directed
Providing and using of boom lift utpo 80 ft alongwith fuel and opretor for complet task, any where inside the Air Force campus complete all as specified & directed. Note:-(i) Contractor will be liable to arrange boom lift only after getting written orders from Engr-in-Charge each time for the minium period of one month i.e. 30 days. The date of arrival and returining back of boom lift will be mentioned in each order saperatly. If contractor fails to provide boom lift by stipulated date, then panel recovery of Rs. 3000.00 per day for the delayed period shall be effected from contractor due payment. (ii) Daily log sheets shall be maintained (which is mandatory requirement) for use of boom lift mentioning daily output. Log sheets shall be signed by contractor. JE concerned, Engineer-in-Charge. (iii) If the boom lift found kept ideal/ standby due to site condition /security reasons during the period, then only 50% of the quoted rate shall be payable to the contractor as standby charges and no other claim of contractor on this account shall be entertained.
Dismantling / taking out / opening of gear motor suitable capacity, complete servicing with material including cleaning and reassembling the same and testing on completion, complete with replacement of following items/ parts : (a) M&L for rewinding of motor with including super enamelled copper winding wire of existing gauge and no of turns. (b) renewal of Bearing motor of existing size complete
S&F in repairs of wheel (pully track) of hanger door existing size, strength, capacity made out of mild steel including taking out old wheel and fixing of new wheel with fixing arrangement as same capacity and size including all safety norms complete all as specified and directed.
Balaji Associate
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .