Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 CrAccepted-AOC NO 79 KANNATHASAN NAGAR MUTHURAMALINGA NAGAR KARAIKUDI 630001 | KARAIKUDI | SIVAGANGAI | TAMIL NADU | 630001 | ₹9.4 Cr | L1 | Accepted-AOC L1 Tenderer Accepted for AOC |
| 2 | L2₹9.6 Cr+₹19.8 L (2.11%)Rejected-AOC | ₹9.6 Cr+₹19.8 L (2.11%) | L2 | Rejected-AOC L2 Tenderer Rejected |
Tender Value
Refer Docs
EMD Value
₹9.9 L
Closing Date
22 Apr 2025, 3:00 pmClosed
Managing Director
No.2, Wallajah Road, Tourism Complex, Chennai - 2
Construction of a New Block at Hotel Tamilnadu, Rameswaram
2025_TTDCL_535718_1
2220A/Engg/2023
Open Tender
Civil Works
Item Rate
450 days
Rameswaram
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹9.9 L
17 Jun 2025
27 Mar 2025
23 Apr 2025
27 Mar 2025
22 Apr 2025
27 Mar 2025
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in Hard rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
For 0 to 2m depth.
For 2 to 3m depth.
Supplying and filling in foundation, basement, etc with following Manufactured sand brought from outside filling materials in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed
Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation, basement, etc with following Good Earth brought from outside materials in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed
Cement Concrete 1:5:10 (One Cement, Five Manufactured sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton.
Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
For plane surfaces such as rectangular, square columns and chamfered sunshades, top and bottom slab of boxing, kitchen platform, loft and such other structural members
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.0 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the departmental officers.
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards.
Foundation and Basement
Ground Floor Super Structure
First Floor Super Structure
Second Floor Super Structure
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using 20mm HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
Supplying, fabricating and placing in position TMT rods for all RCC works as per design given including cost of steel , cover block and G.I. binding wire in all floors etc. complete complying with standard specification.
Brick work in following Cement Mortar using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:6 (One Cement and Six Manufactured Sand) for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction.
For foundation & basement
Ground Floor Super Structure
First Floor Super Structure
Second Floor Super Structure
Brick partition walls of 11.50cm thickness using best quality II Class Ground Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Manufactured Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.
Ground Floor Super Structure
First Floor Super Structure
Supplying and fixing Teak Wood Frames for Doors, Windows, Ventilators and other similar joinery works with the following sizes and sections including labour charges for wrought and put up in position and also for fixing hold fast in frames and masonry etc complete in all floors. Teak Wood Scantling upto 2m length
Supplying and fixing Teak Wood Frames for Doors, Windows, Ventilators and other similar joinery works with the following sizes and sections including labour charges for wrought and put up in position and also for fixing hold fast in frames and masonry etc complete in all floors. Teak Wood Scantling over 2.0m and below 3.0m in Length
Providing and fixing Single Leaf Solid core flush shutters with Teak ply on both side with teak wood lipping alround 35 mm thick. The shutter shall be made of solid core of block board type bonded with PF synthetic resin conforming to BWP grade of IS 848 with 6mm thick teak wood lipping as per drawing. The construction procedure of the shutter should be as per IS 2202. The shutter shall be shop prepared for taking mortice lock or latches suitable lock block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock, covered in IS 2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. The both side door shall be finished with 1mm thick laminate of approved color and pattern. Rate shall include for cost of hardwares (aluminium hinges 125x30mm size - 4 / 3Nos. aluminium aldrop of size - 250x16 mm - 1No. Aluminium tower bolt of size 250x12mm - 1Nos. tower bolt of size 200x12mm - 1No, D type aluminium handle of size 200mm-2No., aluminium door stopper with nylon bush - 1No) as required and fixing them all like lock, hinges, handle, tower bolts, and other accesories etc..as complete with all respects complying with relevant standard specification, as directed by the Departmental officers. a)Sigle leaf solid core flush Shutter for Door
Providing and fixing Double Leaf Solid core flush shutters with Teak ply on both side with teak wood lipping alround 35 mm thick of size 1500 x 2400mm. The shutter shall be made of solid core of block board type bonded with PF synthetic resin conforming to BWP grade of IS 848 with 6mm thick teak wood lipping as per drawing. The construction procedure of the shutter should be as per IS 2202. The shutter shall be shop prepared for taking mortice lock or latches suitable lock block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock, covered in IS 2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. The both side door shall be finished with 1mm thick laminate of approved color and pattern. Rate shall include for cost of hardwares (aluminium hinges 125x30mm size - 8Nos. aluminium aldrop of size - 250x16 mm - 1No. Aluminium tower bolt of size 250x12mm - 2Nos. tower bolt of size 200x12mm - 2No, D type aluminium handle of size 200mm-4No., aluminium door stopper with nylon bush - 2No) as required and fixing them all like lock, hinges, handle, tower bolts, and other accesories etc..as complete with all respects complying with relevant standard specification, as directed by the Departmental officers. a)Double leaf solid core flush Shutter for Door
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the TTDC Engineer before use on work.,
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the TTDC Engineer before use on work., etc complying with standard specification.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc.
Manufacturing, Supplying and Fixing of Wall Handrail of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete complying with standard specification.
Providing and fixing welded M.S. grills for the window openings and any openings as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the departmental officers.., etc complying with standard specification.
Paving the floor / skirting with best quality Double charged vitrified tiles Polished / Matt Size of tiles shall be 800 X 800 X 10 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three Manufactured sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.
Supply and laying with best quality the following materials of Machine Polished granite slab for wash basin counter top of 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.., etc complying with standard specification.
Paving the floor / skirting / steps with best approved quality grade Slab 18mm to 20mm thick and above free from all defects in all floors over a base layer of CM 1:3, 20mm thick. The Granite slab shall be laid over the cement mortar by applying white cement slurry in between base mortar and marble slab and pointed with white cement neatly including polishing with polishing stone and oxalic acid etc. so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges, etc. The marble slabs and other materials to be used shall be got approved by the TTDC Engineer concerned before use on work, etc., complete. ., etc complying with standard specification. Size of marble and pattern as shown in the Architectural Drawing
Paving the floor with Cement Based Hydraulically Pressed Anti skid Tiles (Pattern design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
Dadooing walls with following best approved quality, Vitrified tile set in Cement Mortar 1:3 (One Cement and Three plastering sand) 600mm x300mm x10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed
Dadooing walls with following best approved quality, approved colour Fine polished Granite Slabs of thickness not less than 18mm of size 1200x600 mm, set in Cement Mortar 1:3 (One Cement and Three plastering sand) 20mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed
Supplying and fixing Fine polished Granite Slabs of 18 / 20 mm thick 1200 x 600 mm to shape finished with polished on both sides, slab table rubbed, edges rounded including necessary SS 316 clamps cutting, edge nosing and polishing etc., for urinal partition and any other partitions. Rate including all materials, labour charges, preparation of surface, necessary cutting in wall surface, consumables etc as complete with all respects complying with relevant standard specification
Plastering with Cement Mortar 1:5 (One cement and Five plastering sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification.
Providing and applying Texture paint finish for exterior / interior surface as per Manufacturers specification and as directed. Application of primer by diluting the texture compound by mineral on the plastered surface and apply final two coats of exterior / interior emulsion on the primer. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages, cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification.
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc.,
Finishing the top of roof with one course of Solar Reflective tiles of size 305mm x 305mm x 7mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Manufactured Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification
Semi unitized glazing system with Vision, Vision on Spandrel panel & Spandrel panel / Top hung Openable Panel with the specified DGU Glass - 24 mm thick as described below : Designing, providing and fixing Semi Unitized structural glazing with vision panel & vision on spandrel panel structurally held in position by Structural sealant and factory fabricated, Rate shall include the cost of supplying & fixing of glass, fixing of Top hung window hardwares with Shutter, Flashing around the Glazing, Floor and soffit level smoke seal with GI cover and Compressed Rock wool Insulation, visual mock up and field water test etc. System to be designed to with stand design wind pressure of 200 Kg/Sqm plus Corner Effect 15% of wind load, total pressure shall be 230 Kg/Sqm confirming to IS 875 part 3 and other load, Service load parameters shall be as relavent specification.
Providing and fixing seamless ceiling as shown in the Architectural Drawing with Gypboard of 12.5 mm thick, fixed to the underside of the suspended grid formed by GI Ceiling sections, channels and GI perimeter channel using wood screws and metal expansion rawl plugs. The GI intermediate channel shall be fixed to the suspended strap hanger / GI ceiling angle at intervals not more than 1220 mm. . The joints shall be finished with joint paper tape/ fiber mesh and jointing compound as per manufacturer's specification. Necessary time to be provided for joint curing and then apply 3 layers of the filler compound to provide a smooth surface.The ceiling surface shall be painted with three coats of approved first quality acrylic emulsion with low VOC over a coat of primer. The Quoted rate shall include for providing necessary offsets and grooves, curved profiles as per the drawings, making cutouts for lights, spot lights, duct doors, grills, additional trimming around cutouts for light fittings, grills and also for providing additional supports from ceiling where main / cross members are cut for light fittings for which no extra will be paid separately and working at all heights and levels and as directed by the departmental officers.
With Plain Gypsum board with density not less than 640 kg/m3
With Moisture resisting Gypsum board with density not less than 760 kg/m3
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain / perforated lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre 'T'. The 'T' shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of 'T' section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of 'T' section are made at required intervals not exceeding 1200mm. complete as per standard specification and as directed
Suppy Installation,Testing,Commissioning of 13 Persons Capacity PASSENGER LIFTS (G+1) MRL, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD. Johnson/Kone/ Otis or Equivaent make as per Technical specification as per Annexure 1
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the TTDC Engineer before use on works).
Supply and fixing in position of best Indian make white / colour glazed earthernware long lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.
Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers
Supplying and fixing CP Wall Mixture Tap 3 in 1 system with Hand Showers complying with standard specification and as directed by the Department officers.
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.
Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre long flexible tube including cutting and making good the walls wherever required etc complete. complying with standard specification and as directed by the Department officers.
Supplying and fixing C.P. brass Twin Coat hook fixing with necessary screws etc., complete. fixed on the toilet door complying with standard specification and as directed by the Department officers.
Supplying and fixing C.P. Towel Ring fixing with necessary screws etc., complete. complying with standard specification and as directed by the Departmental officers.
Supplying and fixing Brass Chromium Plated Towel Rail 60cm long and 20mm dia with brackets of same materials including cost of teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.
Supplying and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm using rawl plug & brass screws for fixing etc., complete complying with standard specification
Supplying and fixing stainless steel paper holder with necessary fixing material paper roll etc.complete. complying with standard specification
Providing and fixing stainless steel liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. etc., complete as per standard specification
Supplying and fixing ABS Tissue Paper Dispenser with necessary fixing material , paper roll etc.complete. complying with standard specification
Supplying and fixing electrically operated automatic ABS Hand drier with necessary fixing material , etc.complete. complying with standard specification
Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complying with standard specification
Supplying and fixing in position Indian make bevelled edge mirror of size 600x450mm of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc.,
Supplying and fixing in position Indian make bevelled edge mirror of size 1000x780mm of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc.,
Supplying and fixing in position PVC Nahani Trap / Floor Trap of the size 100x75mm with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) etc., complete complying with standard specification.
Supplying, fixing and testing Screwed heavyduty SS floor cleanout used in sunken floors / ground floor 75/110/160mm dia with gasket and three SS screws for sunken floors, including dismandling masonry works wherever found necessary and making good the damaged portions to the original and giving connections to the pipe as directed etc. complying with standards.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.
50mm dia PVC
75mm dia PVC
110mm dia PVC
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. complete complying with standard specification.
75mm dia PVC
110mm dia PVC
160mm dia PVC
Supplying and fixing PVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge.
75mm dia
110mm dia
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark with solvent cement joints confirming to IS 4985 for Under ground drainage works. The quoted rate shall include necessary earth work, fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting/encasing the pipes if required in cement concrete M-15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required.
110mm dia PVC
160mm dia PVC
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three crushed stone sandand Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications.
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9" x 43/8" x 23/4" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc
600 x600 mm x450mm to 1000mm deep
900 x 900 mm x 1000mm to 1500mm deep
Providing and laying non-pressure class NP2 RCC Spun pipes with collars including excavation of trenches in soil/murum/rock, laying the pipes as per layout and drawing, filling the joints with stiff mixture of cement mortar (1 part cement :1part fine sand) and jute, curing, testing the pipe and refilling the trenches in layers with due compaction & watering etc. complete as directed
200mm dia NP2
250mm dia NP2
Supplying, laying and jointing CPVC pipes SDR 11 (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc.,
15mm dia
20mm dia
25mm dia
32mm dia
40mm dia
50mm dia
65mm dia
80mm dia
Supplying, laying, jointing, testing & Commissioning of uPVC Schedule 80 pressure pipes as per ASTM D 1785 with Sch 80 Fittings as per specifications, jointing with hold tite / super tite & tefflon tape and complete with fittings such as sockets, unions, reducers long or short bends, elbows, nipples flanges,checknuts,etc. Pressure testing of piping and back filling of trench complete as required. The quoted rate shall include necessary earth works, fittings like Tees, Bends, Offsets etc., G.I. brackets with pvc coated GI clamps, nuts & bolts, anchor fasteners, grip bolts, GI threaded, rods, etc., complete
50mm dia
65mm dia
80mm dia
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. etc., complete as per standard specification
20mm dia
25mm dia
32mm dia
40mm dia
50mm dia
65mm dia
Providing and fixing CI D/F Sluice valve with cap / wheel as per IS 14846/2000 PN 1.0 with ISI Marking make of the following dia including cost of bolt & nuts, etc., complete complying with standard specifications (for both internal and external water supply arrangements).
Providing and fixing GM Non return valve as per IS BS 5154 and related IS Specifications make of the following dia including cost of bolt & nuts, etc., complete complying with standard specifications
50mm dia
65mm dia
Providing and fixing of of approved make automatic air release valve 20mm dia to release air lock in pipes as directed
Providing and fixing GI. puddle flanges (IS 1239) fabricated out of 6 mm thick M.S. plate of size 300 x 300mm plus dia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.
25mm dia
40mm dia
50mm dia
65mm dia
80mm dia
100mm dia
Supply and delivery of Electric Monoset centrifugal pump conforming Treated Water Pump (FromTreated Water Sump to O.H.T) Duty of Pump : 300 lpm x 35m head 5.0 HP ( 2nos. - 1 No. Working + 1 No. Stand By)to IS 9079:2002 as amended from time to time, with CI FG 200 Casing, hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be 5.0 HP suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively.
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be 5.0 HP with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % Pump capacity of 300lpm x 50.0 m head 5.0 HP
Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in borewell/Open well including fixing of suction pipe and footvalve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board Consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by EB authorities.
WATER TREATMENT PLANT 8.5 KLD (Capacity 1500 LPH @ 6 hours operation) near Sump / Well Supplying, Installing, testing & commissioning approved make water treatment plant 1500LPH comprising of below units Filter Feed Pump 2 nos. (1 working+1 standby) - Horizontal Monobloc centrifugal pump Capacity: 1500LPH Head 30.0m Make: Kirloskar/EQ Pressure Sand Filter 1 no.- Size: 12”x 52” MOC: FRP with 25 NB Multiport valve Filtering media : Pebbles, Sand Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Hypo Dosing tank 1 no.- Capacity: 50 Ltr. MOC: HDPE Make: Cantax / EQ Hypo Dosing Pumps 1 no. - Capacity: 0-4 LPH Make: Veritose/EQ
Supply, laying, testing & commissioning of the following size cables in suitable HDPE pipes in a trench to be excavated at a depth of 0.75 metre and refiling the earth to make good3.5C x 185 Sqmm Al. Arm Cable
Supplying, Laying, testing & commissioning of the following sizes of Power Cables, Solid Aluminum/copper conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape / Extruded Inner sheathed , Un. Armour or Armour (Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Galvanized wire for cables up to 2x10 sqmm, 3x10 sqmm, 4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, FRLS insulation at outer sheath, 1100V grade as per IS 7098(Part 1) 1988
3.5C x 50 Sqmm
4C x 16 Sq. mm
2C x 6 Sq. mm Cu.
1C x 2.5 Sq. mm PVC Cu. Flexi.cable(For Earthing)
3C x 2.5 Sq. mm Cu. Arm cable(External lighting)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C x 185 Sqmm Al. Arm Cable
3.5C x 50 Sqmm Al. Arm Cable
4C x 16 Sq. mm Al. Arm cable
2C x 6 Sq. mm Cu. Arm cable
1C x 2.5 Sq. mm PVC Cu. Flexi.cable
3C x 2.5 Sq. mm Cu. Arm cable
Supply, erection, testing & commissioning of following sizes of GI Perforatedr type Sheet Metal cable trays and perforation not more than 17.5%, in convenient sections, joined with connectors, Suitable supports from the ceiling/wall as per detailed specification.
300 mm width X 50 mm depth X 2 mm thickness
150 mm width X 50 mm depth X 2 mm thickness
Supplying and fixing of following sizes of Corrugated pattern (min 120gsm) Galvenized Steel (min Z120GSM) Flexible Conduit as per IS:3480 & BS:731-1 latest as on date, helical wound single lock, LFHSUV resistance against corrosion, certain water tightness, Coupler for tight spot installation at both ends. Temperature Range - 25 deg 'C' to +90 deg 'C' and IP rating: 40, complete with all required accessories in such a way wires should not be viewed and proper clamp on surface at max distance of 300mm completed as required
20mm size having ID:17mm, OD:20mm sheet thickness min. 0.25mm
25mm size having ID:21mm, OD:24mm sheet thickness min. 0.25mm
Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:43) horizontal type Distribution boards
Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:43) horizontal type Distribution boards Three pole and Neutral conforming to IS: 8623-1 & 3, made out of pre-treated and powder coated (minimum 60-80 micron), minimum 1.2mm thick sheet steel double door enclosure (IK 09), 500 V, mount on surface / recess, complete with minimum 3 x 63A tinned copper insulated prong type short links with end cap , common neutral bus bar, common earth bar, din bar, interconnections including earthing stud etc. as required. The cost shall include required minimum 10sqmm copper insulated interconnection wire set, blanking Plates, sticking saddles, cement spill protector, cable ties, circuit identification labels & laminated DB Detail chart as standard or as suggested by Architect/Consultant. (As described below)Incomer1 No. 63A, 4P MCB18 Nos. 6A/10A/16A/20A/32A SP MCB's
Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:43) Distribution boards Single pole and Neutral conforming to IS: 8623-1 & 3, made out of pre-treated and powder coated (minimum 60-80 micron), minimum 1.2mm thick sheet steel double door enclosure (IK 09), 240 V, mount on surface / recess, complete with minimum 63A tinned copper insulated prong type short links with end cap, neutral bus bar, earth bar, din bar, interconnections including earthing stud etc. as required. The cost shall include required copper insulated wire set, blanking Plates, sticking saddles, cement spill protector, cable ties, circuit identification labels & laminated DB Detail chart as standard or as suggested by Architect/Consultant. (As described below)12 WAY SPN(CDB)Incomer1 No. 32A, DP RCBO 30mAOutgoing10 Nos. 6A/10A SP MCB's
Supplying and fixing following way SPN MCB Distribution Board suitable for 230 V 1 Ph, 50 Cycles AC supply, IP 43 Protection Double Door made of sheet steel, dust protected, duly powder coated on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, including earthing etc. complete with Incoming and outgoing MCBs as per SLD & Specification16 Way SPN MCB FLEXI DB (DELUXE)Incomer32 A DP RCBO - 30mA Sensitivity -1No.32A,DP,AC duty Modular contactor - 1No.Outgoings1 No 20A, SP 'C' Curve MCBs 3 Nos 16A, SP 'B' Curve MCBs 2 Nos 10A, SP 'C' Curve MCBs as per DB SLD & Specification.
16 Way SPN MCB FLEXI DB (DELUXE/LIVING ROOM) Incomer 32 A DP RCBO - 30mA Sensitivity -1No. 32A,DP,AC duty Modular contactor - 1No. Outgoing 2 Nos 20A, SP 'C' Curve MCBs 3 Nos 16A, SP 'B' Curve MCBs 3 Nos 10A, SP 'C' Curve MCBs as per DB SLD & Specification.
Electronic key card switch with 30 sec delay with plate,3module box with card with necessary accessories etc.,
Isolator 63A,4P, MCCB in suitable MS enclosure with RYB indicator (For Lift M/c.)
Earthing
Body Earthing with 17.2mm Dia 3Mtr.long Copper bonded steel rod including accessories and providing brick masonary work and enclosures with RCC slab and watering pipe etc.,with Earth enhancing compound including excavation, refilling etc as required.
Providing and fixing following sizes of copper strip on surface or in recess for connections etc. as required. The cost shall include necessary Terminal blocks for looping earth conductor. 25 x 3 mm GI.Flat
Providing and fixing following sizes of copper strip on surface or in recess for connections etc. as required. The cost shall include necessary Terminal blocks for looping earth conductor. 8 SWG. Cu.
Wiring for SWITCH Controlled light & Fan point with 1.5Sqm FRLS PVC insulated multistrandeded copper conductor 1100 Volt grade wires in MS surface/concealed conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted modulr switch with moulded cover plate in zinc chromate passivated MS box, including the cost of running 1.5 sq mm green colour FRLS PVC insulated copper solid conductor wire for loop earthing complete as per specifications and as required, including providing of 2x1.5 sq.mm. +1.5 sq.mm. (E) circuit wiring from DB to switch board. (Cost of MCB not to be included in this item)
Primary Point
Secondary Point
Point Wiring(FRLS Wires) for MCB Controlled light point with 1.5Sqm FRLS PVC insulated multistrandeded copper conductor 1100 Volt grade wires in MS surface/concealed conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of supplying and fixing a 6 Amp 240 Volt grid plate mounted modulr switch with moulded cover plate in zinc chromate passivated MS box, including the cost of running 1.5 sq mm green colour FRLS PVC insulated copper solid conductor wire for loop earthing complete as per specifications and as required, including providing of 2x1.5 sq.mm. +1.5 sq.mm. (E) circuit wiring from DB to switch board. (Cost of MCB not to be included in this item)
Primary Point
Secondary Point
Wiring for Primary Power point Wiring for 6 pin 6/ 16 A Power plug point controlled by 16A Switch with 2 x 4 Sq. mm + 1 x 2.5 Sq.mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixing Modular 6 pin 6A/ 16 A socket outlet controlled by 16 A switch in zinc chromate passivated MS box, complete as per specification and as required.
Wiring for 5 pin 6A plug point controlled by 6A Switch with 2 x 2.5 Sq. mm + 1 x 1.5 Sq.mm PVC insulated FRLS multi strand copper conductor 1100 Volt grade wires in recessed/surface MS conduit with accessories including cost of providing saddles etc for surface conduiting and/or cost of cutting chases for recessed conduiting, including the cost of providing & fixing Modular 5 pin 6A socket outlet controlled by 6 A switch in zinc chromate passivated PVC box, complete as per specification and as required. (raw +ups circuits both)
AC PONIT(Switches and sockets)
Supply and fixing of suitable 2module MS box with modular plate with 20A DP switch with indicator etc.,
Supply and fixing of suitable 2module MS box with modular plate with 20A 3pin socket etc.,
DPR to Primary Lighting Switch Box Wiring for Primary Lighting switch box with 2 x 2.5 sq. mm. along with 1 x 2.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed /open 2mm thick FRLS PVC conduit with necessary accessories etc.,
Primary to secondary Lighting Switch Box Wiring for Primary Lighting switch box with 3 x 1.5 sq. mm FRLS PVC insulated multistranded copper wire in recessed /open 2mm thick FRLS PVC conduit with necessary accessories etc.,
Supplying and fixing of 6A micro switch for to control light fixed in the ward drobe on surface including necessary wirings.
Wiring for Lift Well Light Point and socket oulet with 2 x 1.5 sqmm FRLS PVC insulated Stranded Copper Conductor wire along with 1 x 1.5 sqmm PVC insulated Stranded copper conductor wire as earth wire in surface with ERW MS conduit including providing and fixing Galvanised / Cadmium plated MS switch box, 2 no 6A Single Way Modular Switch for (controlling light point and socket Outlet) , 1 No 6 A 5 Pin shuttered modular socket outlet , modular plate and making necessary connections etc., as per specification.
Wiring for Staircase Light Point with 2 x 1.5 sq. mm. along with 1 x 1.5 sq. mm (E). FRLS PVC insulated Stranded copper conductor single core cable in recessed ISIPVC conduit including providing and fixing suitable Galvanised / Cadmium plated MS box, 6A Two-Way modular Switch, modular plate and making necessary connections, earthing etc. complete as per specification.
Wiring for Fan Point with 2 x 1.5 sq. mm. along with 1 x 1.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed/open 2mm thick FRLS PVC conduit with fan box including providing and fixing suitable MS box, 6A modular Switch, 100 Watt modular step Regulator(2 M), modular plate and making necessary connections, earthing,fan hook with anchor fastener with necessary accessories etc. complete as per specification.
Wiring for Two way Light Point with 2 x 1.5 sq. mm. along with 1 x 1.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed /open 2mm thick FRLS PVC conduit including providing and fixing of suitable Galvanised / Cadmium plated MS box, 6A Two-Way modular Switch, modular plate and making necessary connections, earthing etc. complete as per specification.
Wiring for Exhaust Fan Point with 2 x 1.5 sq. mm. along with 1 x 1.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed/open 2mm thick FRLS PVC conduit including providing and fixing suitable MS boxes, 6A one-Way modular Switch, modular plate in the lighting switch box and 6A 3Pin socket with moduler plate nearby fan and making necessary connections, earthing etc. complete as per specification.
Wiring for Calling Bell Point with 2 x 1.5 sq. mm. along with 1 x 1.5 sq. mm (E).FRLS PVC insulated Stranded copper conductor single core cable in recessed/open 2mm thick FRLS PVC conduit including providing and fixing suitable MS box, 6A Bell push DP Switch with indicator, modular plate and making necessary connections etc. complete as per specification.
Supplying and fixing of 6 A one-way modular Switch, Dependent 6 A, 5 pin, modular shuttered socket outlet and making connections, earthing etc. , complete as per specification. ( Switch Board Plug )
Wiring for Geyser socket 16A socket outlet with 2 x 2.5 sq. mm. along with 1 x 2.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed /open 2mm thick FRLS PVC conduit with necessary accessories etc. complete as per specification.
16A switch box for geyser 16/6A,5 pin Switched Socket with Front plate and flush mounting MS box with necessary items etc.,
16A socket box for geyser 16A Socket with front plate and flush mounting MS box with necessary wirings and accessories
Wiring for kettle socket 16A socket outlet with 2 x 2.5 sq. mm. along with 1 x 2.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed /open 2mm thick FRLS PVC conduit with necessary accessories etc. complete as per specification.
kettle socket Box 16/6A,5 pin Switched Socket with Front plate and flush mounting MS box with necessary items etc.,
Wiring for shaver docket point with 16A socket outlet with 2 x 2.5 sq. mm. along with 1 x 2.5 sq. mm (E). FRLS PVC insulated multistranded copper wire in recessed /open 2mm thick FRLS PVC conduit including providing and fixing suitable MS box, Shaver socket with switch with moduler plate with necessary accessories etc. complete as per specification.
Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED Square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of 20W LED Batten type fitting with support from ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply of 10W LED Bulkhead Luminaire with a nominal system lumen output of 700 lumens and system power consumption of 6.5W. The luminaire should have a color temperature of 6500K. The luminaire housing should be made of high pressure die cast Aluminium. Luminaire should be IP65 & IK08 rated.
Supply & Fixing of 10W LED weather proof light fitting with necessary fixing accessories required as per the site condition.
Supply & Fixing of 30W LED COB light fitting with necessary fixing accessories required as per the site condition.
Supply & Fixing of 10W LED bollard light fitting with necessary fixing accessories required as per the site condition.
Supply & Fixing of Decorative wall mount 18W LED light fitting with necessary fixing accessories as required as per the site conditions.
Supply & Fixing of LED SIGNAGE light fitting with necessary fixing accessories as required as per the site conditions.
Supply & Fixing of 10W LED Mirror light fitting with necessary fixing accessories required as per the site condition.
Supply & Fixing of 10W LEDrecessed mount(Round)light fitting with necessary fixing accessories required as per the site condition.
Supply & Fixing of 5W LED Night lamp fitting with ms enclosure box recessed in wall with necessary fixing accessories required as per the site condition.
Supply & Fixing of 3W LED Spot light fitting with necessary fixing accessories required as per the site condition.
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of TV commercial model with 3 years warranty of 43 inch LED display smart android television with necessary fixing accessories as required as per the site condition(Make: Samsung, LG OR Equivalent). (GST @ 28%)
Supply & Drawing high density polyethelene insulated, solid annealed high conductivity 0.5 mm dia bare copper , following pair , polyester taped and sheathed with high oxygen index Fire Retardent PVC compound , generally conforming to ITD specifications in existing recess PVC conduit making connections etc as required.
50 Pair (Armoured cable)
Supplying and fixing of following pair krone type PVC/MS Powder Coated telephone junction box in surface with hinged cover and screwed type tag strips i/c testing of all telephone cable numbering and making connection as reqd.
50 Pair (Armoured cable)
Telephone Intercom Point -Supplying and fixing suitable MS Switch box with modular plate and cover in front on surface or in recess, including providing and fixing RJ 11 modular Telephone outlet making connection etc. complete as per specification..
TV/AV Signal Point outlet ,Supplying and fixing of 2module galvanised / cadmium plated MS Switch box with co-axial socket outlet & 1module front plate cover in front on surface or in recess.
TV/AV Signal Point outlet Supplying and Fixing 6 MODULE cadmium plated / galvanised M.S Switch box in recess with Hylum Sheet cover in front as per specifications (Telephone/TV Junction box)
Supply & Laying of RG 6 TV foam insulated copper conductor double screened with aluminium foil and aluminium alloy braiding Coaxial Cable in the existing PVC conduit complete as required
Supplying and Laying of following 25mm dia FRLS PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required: (from the comm shaft to end point)
Supply, Installation, Testing and Commissioning of Medium Voltage floor / Wall mounting Cubicle Type Distribution Board suitable for 415V, 3 Phase, 50 Hz Power Distribution System with the following mounting complete as per specifications attached. MAIN PANEL - As per SLD & Specification Incomer 250A,TPN MCCB - 1No Indication/ON/OFF TRIP lamp 1set of RYB LED lamp Metering Multifunction meter with suitable CT BUSBAR 1 set of 250 A ,35kA,TPN Aluminium Bus Bar Outgoings 100A,TPN,MCCB - 4Nos.63A,TPN,MCCB - 5Nos.
Supply, Installation, testing & commissioning of storage type ISI Mark 20L Vertical Type Instant Geyser along with all necessary hardwares required for fixing and necessary pipe connections.
Sub Head-IV - Lighting Arrester
Five Pronged Lighting Spike Fixed on Gun Metal Ball Mounted on 19mm Dia Copper Tube 1Mtr Long with Gun Metal 150mm Dia base with all accessories for fixing of the down Conductors.
Providing and fixing 25 mm X 3 mm thick GI Flat on parapet for lightning conductor complete as required. (For horizontal run)
Providing and fixing 25 mm X 3 mm thick GI Flat thick on surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 25 mm X 3 mm thick GI strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as required.
Body Earthing with 17.2mm Dia 3Mtr.long Copper bonded steel rod including accessories and providing brick masonary work and enclosures with RCC slab and watering pipe etc.,with Earth enhancing compound including excavation, refilling etc as required.
Fire extinguisher
Supply & providing Co2 5Kg (Dry chemical ) Fire extinguisher with necessary mounting bracket and fixed neatly in panel room
Supplying and fixing PVC Synthetic Elastomer electrically Insulating Mat as per IS: 15652-2006 & CPRI tested of the following rating . Class A insulation - 2 mm thickness upto 3.3 KV
Charges for preparation of As built drawings for MV installations and obtaining approval of drawings, arranging inspection and obtaining safety certificate from Electrical Inspectorate also excluding receiptable fee payable to them .
Professional charges towards obtaining permission for Installation as well as for running of LIFT from Chief Electrical Inspector and any other statutory body as may be required.
Supply, installation, testing and commissioning of Micro Processor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
Supply and laying of FRLS PVC insulated 2 core 1.5 Sq.mm. Armoured Copper Cable on ceiling / wall using Fixing accessories like screws, plug, clamps, etc., as Per standard methods and as directed by the Departmental Officers.
Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods andas directed by the Departmental Officers. (Make: Apollo /Equivalent)
Supply, Installation, Testing & Commissioning of Heat detector with sensing chamber , 12/24 volt DC twin visual alarm indicater blink in stand by and steady in alarm (LED) complete in all respect with Base as required
Supply, Installation, Testing & Commissioning of Response Indicator complete with Box as required
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent)
Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Ravel / Equivalent)
PA Sysytem - Supply, installing, testing and commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W Ceiling Mounted Speakers
PA Sysytem - -Wiring for Music Speaker points to be carried out with of 2 * 40/0.2 mm PVC insulated, twin twisted cable , in surface/ recessed PVC conduits. Wiring will begin from the Music System panel and will terminate in each shop as shown in the drawings. Work includes repair of chase to original finish.
PA Sysytem - installing, testing and commissioning of 1X100W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. (Supply not in our scope only labour charge )
CCTV sysytem -Supplying and drawing of CAT 6 UTP wire in existing MS conduit
CCTV sysytem - Supplying and laying of 25 mm dia MS conduit for CCTV Camera
Supply, Installation, Testing and Commissioning of 2MP x IR Fixed lens Turret Camera, 1920 X 1080 at 25/30fps,1/2.9"CMOS, Fixed lens 2.8mm,H.265, H.264 compression,Smart Compression, internal 850nm IR Range 30 meter or better,Built in Microphone, 100dB true WDR as per IEC62676, Triple streaming, Motion Detection,Camera sabotage,IP66,IK10 Housing,Camera shall support SD card 512GB or better ,ONVIF profile S,G, & T,NDAA,UL/cUL Listed, UL 60950-22, CE, FCC.
Supply, Installation, testing and Commissioning of Network Video Recording Storage System: Video management system - 32 channels. Support 340 Mbps bandwidth throughput capacity. Storage @ 720P with 20 FPS for 30 days recording.
DX CEILING SUSPENDED DUCTABLE UNITS:- Supply, installation, testing and commissioning of Inverter Ductable type split Unit of following capacities with eco-friendly refrigerant. The Indoor unit shall comprise of Blowers, Cooling coil, Filter and Expansion device and drain pan. The Outdoor unit shall comprise of scroll Compressor, Air cooled condenser & Condenser fans. Rate inclusive of refrigerant charging, power cable from the panel/isolator, control cable, remote controller, supports for indoor units,isolators, supports, necessary civil foundation / pedestal / cutout works, etc as per the OEM standard as well as Client. etc. The Price Shall include the 5 Rmtrs of Copper pipes suitable for the proposed unit capacity & Fire rated Canvas.Carrier/HITACHI/Thosibha/Blue star or Equivalent Make
1.5 TR 600 cfm (GST @ 28%)
2.0 TR 800 cfm (GST @ 28%)
Supply, installation, testing and commissioning of factory made lock-forming quality rectangular GI ducting, complying with IS: 277 and having 120 GSM coating classification. The price include the cost of necessory accessories & supports (like TDF flanges, ms angle flanges, neoprene gaskets, threaded rod, corner saddles, guide vanes as per SMACNA standards, joints, labelling etc.. a)0.6 mm - 24 G
Supply and installation of Powder coated extruded aluminium grilles & Louvers without collar damper. The rate shall inclusive of necessary fixing and supporting arrangement for the grilles. The Grille colour shall be Pre-Approved by Client/ Architect.
Supply, installation and commissioning of the following capacity Wall mounted Propeller Fans. The fan shall be of noiseless operation and having good aesthetic. The fan motor shall be suitable for operating on 415±10% V, 3 phase, 50Hz AC supply & 230V, 1 phase, 50Hz AC supply. Location of the fan shall be in the peripheral wall. The cost shall inclusive of required length and adequate power wiring from the nearest panel / socket to the fans, wall housing, vermin net on both sides, louvers on one end, steel supports required for mounting the fan and bird screen, wire mess and storm proof louers as required. The fan shall have min ESP of 10mmWC
Supply, Installation, testing and commissioning of factory-fabricated, assembled,tested, and finished, direct-driven Rectangular/Circular fans consisting of internally lined housing, wheel, fan shaft, bearings, motor, drive assembly, with joints between sections sealed. The mounting frame will be Galvanized Steel frames of minimum 3-mm Thick with factory fabricated corner pieces. The price shall be inclusive of pre filter and neccesary frame for Exhaust air fans.
Supply, installation, testing and commissioning DUCT ACOUSTIC INSULATION of 10mm thickness of fibre free open cell nitrile rubber foam.
JOHN KENNADY (BID ID -1309093)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 0.24 MB
BOQ.xls
BOQ • 16.65 MB
Tenderdocument_2.pdf
Tender Documents • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .