Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹51.0 L+₹2.1 L (4.23%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹54.1 L+₹5.2 L (10.6%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹56.6 L+₹7.6 L (15.6%)Rejected-Finance MALANCHA ROAD KHARAGPUR 721304 DIST WEST MIDNAPORE WEST BENGAL | KHARAGPUR | WEST MIDNAPORE | WEST BENGAL | 721304 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹56.6 L+₹7.7 L (15.7%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Jan 2025, 6:00 pmClosed
MAJOR MK YADAV, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIRS AND MAINTENANCE OF LT OG/UG, PANEL BOARD, CABLES, ISOLATION TRANSFORMER, APFC PANEL, VOLTAGE STABILIZER AND ALLIED WORKS IN TECH AND DOMESTIC AREA AND DDK RANGE UNDER GE(AF)KALAIKUNDA
2024_MES_669555_2
C/8041/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹90,000
Yes
6 Mar 2025
9 Dec 2024
7 Jan 2025
9 Dec 2024
6 Jan 2025
23 Dec 2024
Amount
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material all as specified and directed. (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 400 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
All as per BOQ Item No 3.00 here-in-before but of size 3.5 core 300 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 3.5 core 240 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 3.5 core 185 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 3.5 core 120 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 3.5 core 70 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 3.5 core 35 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 4.0 core 25 sqmm. ,complete all as specified
All as per BOQ Item No 3.00 here-in-before but of size 4.0 core 16 sqmm. ,complete all as specified
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)
Supply and laying fly ash bricks best quality, laid in trenches, perpandicular to U/G cable for cable protection complete all as specified.
Laying only old bricks obtained from item No 02 perpandicular to U/G cable for cable protection complete all as specified.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
M & L for Boring of horizontal hole under road, pavement, hardstanding suitable for passing through up to 80 mm bore, complete all as specified. Note : (i) One run of boring of horizontal hole will be measured as one unit length. (ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account. (iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 80 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.
Supplying and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.
Supply and fixing FRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size 16 Sqmm single core including copper lugs complete all as specified and as directed including taking out the existing one.
Supply and fixing FRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size 25 Sqmm single core including copper lugs complete all as specified and as directed including taking out the existing one.
S&F MCCB 125 Amps rating, 4 pole , 415 V, AC, 50 HZ, adjustable thermal & adjustable magnetic setting setting, Ics-100 % Icu , service breaking capacity 16 KA, including all accessories like spreader terminals and separator ,etc. including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables and taking down old unserviceable MCCB all as specified and directed by Engineer in Charge
S&F MCCB 160 Amps rating, 4 pole , 415 V, AC, 50 HZ, adjustable thermal & adjustable magnetic setting setting, Ics-100 % Icu , service breaking capacity 25 KA, including all accessories like spreader terminals and separator ,etc. including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables and taking down old unserviceable MCCB all as specified and directed by Engineer in Charge
S&F MCCB 250 Amps rating, 4 pole , 415 V, AC, 50 HZ, adjustable thermal & adjustable magnetic setting setting, Ics-100 % Icu , service breaking capacity 36 KA, including all accessories like spreader terminals and separator ,etc. including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables and taking down old unserviceable MCCB all as specified and directed by Engineer in Charge
S&F MCCB 400 Amps rating, 4 pole , 415 V, AC, 50 HZ, adjustable thermal & adjustable magnetic setting setting, Ics-100 % Icu , service breaking capacity 36 KA, including all accessories like spreader terminals and separator ,etc. including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables and taking down old unserviceable MCCB all as specified and directed by Engineer in Charge.
S&F MCCB 630 Amps rating, 4 pole , 415 V, AC, 50 HZ, adjustable thermal & adjustable magnetic setting setting, Ics-100 % Icu , service breaking capacity 50 KA, including all accessories like spreader terminals and separator ,etc. including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables and taking down old unserviceable MCCB all as specified and directed by Engineer in Charge.
M & L for jointing heat shrinkable 1100 volts XLPE straight through joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 240 to 300 sqmm 3½ core 1100 volts grade and necessary testing after jointing, complete all as specified and directed.
M & L for jointing heat shrinkable 1100 volts XLPE straight through joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 150 to 185 sqmm 3½ core 1100 volts grade and necessary testing after jointing, complete all as specified and directed.
M & L for jointing heat shrinkable 1100 volts XLPE straight through joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 400 to 500 sqmm 3½ core 1100 volts grade and necessary testing after jointing, complete all as specified and directed.
M & L for jointing heat shrinkable 1100 volts XLPE straight through joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 70 to 120 sqmm 3½ core 1100 volts grade and necessary testing after jointing, complete all as specified and directed.
Taking down old unsv/ corroded LT feeder pillar box/ DB Box/ Busbar Chamber of any sizes or types (after disconnection of all electrical connections) complete for replacement with new one all as specified and directed by Engr-in-Charge.
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.50m x 1.00m x 0.75m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar rated 600 Amps made of copper ETP grade pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.50m x 1.50m x 0.75m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar rated 950 Amps made of copper ETP grade pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one :
Note:- (i) All MCCB/MCB should be of approved Make (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB.(vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s (ix) Rate of panel include refixing of all cables in panel which are dismantle & taking out from old unserviceable panel.
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.50m x 1.50m x 0.75m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar rated 600 Amps made of copper ETP grade for incommer for outgoing pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one :
Note:- (i) All MCCB/MCB should be of approved Make (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB.(vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s (ix) Rate of panel include refixing of all cables in panel which are dismantle & taking out from old unserviceable panel.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI strip of size 32x6 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 40 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 4mm including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
Supply and fixing copper lug suitable of 25 Sqmm copper cable all as specified and directed
M&L for detecting of fault in 1100V (E) LT cable of any size , 3½ core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required.(ii) Cable if replaced & cost of Jointing kit shall be measured & paid separately.
Supply & fixing Busbar chamber, wall mounted, capacity 630 Amp, 4way, 415 volt, 4 Nos equal copper bar complete all as specified and as directed including taking down the existing one..
Supply & Fixing Automatic transfer switch of 250 Amp, 4 pole, 415 Volt , 50 HZ, with enclosure and autmatic/manual setting and complete protection, including connection with the existing cables and taking out old ATS complete all as specified and directed by Eng in Charge.
Supply & fixing in repairs 3 pole contactors, 415 volt, 65 A integrated auxiliary contacts 2 NO + 2NC complete all as specified and as directed
S&F in repair ACB 800 Amp for distribution network with Microprocessor release IPR 1+ ,4 Pole, 415V, 50 kA, Ics=100%Icu with short circuit breaking capacity , manual draw out type Conf to IEC 60947-2 including all accessories . including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables all as specified and directed
S&F in repair ACB 1600 Amp for distribution network with Microprocessor release IPR 1+ ,4 Pole, 415V, 50 kA, Ics=100%Icu with short circuit breaking capacity , manual draw out type Conf to IEC 60947-2 including all accessories . including fixing it in existing location by making all arrangement as required on site , connecting incoming and out going cables all as specified and directed
M&L for cement concrete ( 1:3:6) type C-2 using 40mm graded crushed stone aggregate as in pole foundation, filling and mass concrete complete including demolition all as specified
M&L for cement concrete ( 1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping of pole including weathering, slightly rounded or chamfered angles and throating, necessary formwork including demolition as directed complete all as specified
Material & labour for service charges of 3 Phase servo controlled voltage stabilizer of capacity upto 150 kVA after disconnection from supply,removing old faulty spare parts and replace with new one, complete overhauling including testing after repair work complete all as specified & directed. Note : Spare parts shall be measured and paid separtely under relevant items as supply only.
Supply only the followings :-(only to be measured when incorporated against BOQ Srl No 47.00 Here--in-before)
Control circuit with motor & enclosure
AC synchronous Motor 10 KG
Bypass switch
Variac
R.C. Net work
Repairing charges of Variac
Repairing charges of contactor
Material & labour for service charges of 3 Phase servo controlled voltage stabilizer of capacity above 150 KVA to 300 kVA after disconnection from supply,removing old faulty spare parts and replace with new one, complete overhauling including testing after repair work complete all as specified & directed. Note : Spare parts shall be measured and paid separtely under relevant items as supply only.
Supply only the followings :-(only to be measured when incorporated against BOQ Srl No 49.00 Here--in-before)
control circuit with motor & enclosure
AC synchronous Motor 20 KG
Bypass switch
Supply only Variac
R.C. Net work
Repairing charges of Variac
Repairing charges of contactor
Material & labour for service charges of 3 Phase servo controlled voltage stabilizer of capacity above 300 KVA to 630 kVA after disconnection from supply,removing old faulty spare parts and replace with new one, complete overhauling including testing after repair work complete all as specified & directed. Note : Spare parts shall be measured and paid separtely under relevant items as supply only.
Supply only the followings :-(only to be measured when incorporated against BOQ Srl No 51.00 Here--in-before)
control circuit with motor & enclosure
AC synchronous Motor 20 KG
Bypass switch
Supply only Variac
R.C. Net work
Neon lamp
Repairing charges of Variac
Repairing charges of contactor
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 10 KVAR without incoming MCCBs complete all as specified including dismantling the existing one.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 15 KVAR without incoming MCCBs complete all as specified including dismantling the existing one..
M/S SINGH ENTERPRISE (BID ID -3202196)
Sai & Siva Enterprises (BID ID -3201824)
T K Construction (BID ID -3202004)
MS R.K.ENTERPRISE (BID ID -3202308)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .