Loading…
Loading…
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
21 Jan 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
66 days
Expenditure
Capital (Works)
WORKS
10 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor. For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Electrical arrangements for: Chennai Division: Provision of Foot Over Bridge at Chennai Beach station(MSB)
ME-29-II-1078-2025~SR
ME-29-II-1078-2025
Open
Works - General
60 Days
Chennai, Tamil Nadu
₹0
₹15,000
21 Jan 2026
30 Dec 2025
7 Jan 2026
47 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 7,49,788 | ||
| — | — | — | Above/ 52400.00 Below/P | ||
| Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. | — | 400.00 | — | — | |
| — | — | — | Above/ 11600.00 Below/P | ||
| Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 400.00 | — | — | |
| — | — | — | Above/ 6180.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material within railway land complete in a manner as directed by the Section Engineer in charge at site. | — | 15.00 | — | — | |
| — | — | — | Above/ 62850.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. | — | 15.00 | — | — | |
| — | — | — | Above/ 29000.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx35 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 1000.00 | — | — | |
| — | — | — | Above/ 15000.00 Below/P | ||
| Laying/leading of 4 core 50 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx50 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 17500.00 Below/P | ||
| Laying/leading of 4 core 70 sq.mm LTUG Aluminium cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note:- 4Cx70 sq.mm LTUG Aluminium Cable alone will be supplied departmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 158600.00 Below/P | ||
| Supply and Laying of 63 mm dia ISI Marked High Density Polyethylene pipes of material grade PE-100 and with Pressure rating of 8.0 P.N conforming to IS: 4984 / 1995 or latest in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. | — | 1300.00 | — | — | |
| — | — | — | Above/ 25392.00 Below/P | ||
| Supply, Installation, Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of masonry earth pit enclosure, provision of cover etc, complete including supply / leading / laying / burying and concealing of GI strip 25 X 3 mm from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site.Note: 1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. | — | 4.00 | — | — | |
| — | — | — | Above/ 13320.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multi-stranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid vide item No. 11 below complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 180.00 | — | — | |
| — | — | — | Above/ 6300.00 Below/P | ||
| Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] confirming to IS: 9537/P3/1983 or latest [ISI Marked] with wall thickness not less than 2.0 mm along with all accessories like Bends,Junction Boxes and other items required as per site conditions and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting walls to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. | — | 180.00 | — | — | |
| — | — | — | Above/ 2700.00 Below/P | ||
| Supply and Drawing of earth wire using 1.5 sq.mm fire retardant Low smoke PVC insulated [green colour] unsheathed single copper conductor cables of 1100 V grade conforming to IS: 694/1990 or latest along wires vide item No. 10 above and from MCB DB to switch boards and switch boards to light and fan points or elsewhere in a manner as directed by Senior Section Engineer in charge at site. | — | 180.00 | — | — | |
| — | — | — | Above/ 4000.00 Below/P | ||
| Installation, Testing and commissioning of 4 feet 20W LED light fitting Batten type suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4 feet LED 20W light fitting Batten Type with lamp alone will be supplied Departmentally | — | 80.00 | — | — | |
| — | — | — | Above/ 9300.00 Below/P | ||
| Supply, Installation, Testing and commissioning of PVC junction box comprising of 1 No. 4 way 32A per way strip connector block and including fixing of 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and fixing the same close to lamp including wiring from junction box to lamp fitting by using 3 core 1.0 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper (White/Ivory colour) conductor flexible chord in a manner as directed by Sr. Section Engineer in charge at site. | — | 60.00 | — | — | |
| — | — | — | Above/ 19738.00 Below/P | ||
| Supply, Installation,Testing and commissioning of of time switch assembly comprising of: - a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz]. b)1 No. 3 pole 25A power contactor conforming to IS: 13947/P4/1993 or latest, c)1 No. 40A DP [MCB type] isolator conforming to IS: 13947/P3/1993 or latest, d)1 No. Neutral link etc. e)1 No. Earth link etc. f) Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well- seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site. | — | 2.00 | — | — | |
| — | — | — | Above/ 35098.00 Below/P | ||
| Supply of sheet steel enclosed 200A, 36kA, FP, MCCB with adjustable thermal and fixed magnetic settings, shunt trip, rotary handle etc. conforming to IS: 13947/P2/1993 or latest and erection,testing and commissioning of the same onto wall, or elsewhere using suitable mounting arrangements including all cable terminations and all other works and items required complete as per site conditions and in a manner as directed by Section Engineer in charge at site. Note: Enclosure shall be suitable for termination of LTUG cable at top and bottom side | — | 2.00 | — | — | |
| — | — | — | Above/ 43260.00 Below/P | ||
| Supply, Erection, Testing and commissioning of 4 way TPN MCB DB with combination of 100A,30 kA, FP,MCCB as Incomer along with (4 No's of 16A+4 No's of 20A +4 No's of 32A),SP,MCB's as feeder controls along with Cable adaptor box on to the wall using suitable angle iron frame work and including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete including all internal wiring connections and terminations and as per industrial practices complete as per site conditions and in a manner as directed by Senior Section Engineer in charge at site. | — | 2.00 | — | — | |
| — | — | — | Above/ 49540.00 Below/P | ||
| Supply of 45w LED flood light fitting suitable to work on 240V single phase 50 Hz AC supply as per specification enclosed with lamp and all standard accessories and provision of the same using suitable fixing arrangements onto new lamp posts in a manner as directed by Section Engineer in charge at site. | — | 20.00 | — | — | |
| — | — | — | Above/ 114990.00 Below/P | ||
| Supply of 4 meters long Octagonal Pole totally hot dip galvanized with minimum of 70 mm dia at top and 130mm dia at the bottom, the plate thickness for pole shall be not less than 3mm, without any intermediate joints, 1 No hot dip galvanized 48mm dia pipe Double Arm arch bracket, Base plate of size not less than 200 X 200 x 12mm with 4 Nos 20mm dia hole, 4 Nos of foundation bolts M16-not less than 600mm long with nuts and washers, two numbers of re-wireable type porcelain fuse base and fuse carrier having a current rating of 16A and voltage not exceeding 650V between lines and conforming to IS: 2086 / 1993 or latest and erection, testing and commissioning of the above octagonal pole onto the suitable RCC foundation by using modern engineering practice and in a manner as directed by Section Engineer in charge at site. Note: 1)The foundation shall be as per the standard practice and recommendation of the manufacturer of octagonal pole. 2)The foundation design and drawing along with supporting IS specifications suitable as per site conditions should be submitted for Approval before starting the work. | — | 10.00 | — | — | |
| — | — | — | Above/ 4200.00 Below/P | ||
| Supply and wiring to street lights from distribution box provided in the lamp post using 3 runs of 1.5 sq. mm of PVC insulated single core multi stranded copper conductor of 1100 V grade confirming to IS: 694/1990 or latest duly inside the tubular post in a manner as directed by Section Engineer in charge at site. Note: 3 runs of 1.5 sq. mm copper conductor is taken as 1 m for unit purpose | — | 100.00 | — | — | |
| — | — | — | Above/ 52260.00 Below/P | ||
| Supply of perforated cable trays of 300mm width X 50mm height made of 2.00mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated using 40x40x6 mm MS angles for the longitudinal members and 40 x 6mm MS flats for the cross members and erection, testing and commissioning of the same duly supported from walls/ ceiling/roof purloins/structural steel works or elsewhere using intermediate supports by 40x6 mm MS flats complete in a manner as directed by Section Engineer-in-charge at site. Note:-The cable tray supports shall be applied with two coats of red oxide primer and painted with two coats of bright aluminium paint. | — | 60.00 | — | — | |
| — | — | — | Above/ 5460.00 Below/P | ||
| Supply and provision of MS brackets, fabricated as per sketch enclosed, for supporting OH wire beneath platform shelters, mounted with 4 Nos. of porcelain vertical reel / shackle insulators and earth stud / bolt, finished with 2 coats of red primer and 1 coat of aluminium paint and complete with fixing arrangements as per drawing enclosed and in a manner as directed by Section Engineer in charges at site. | — | 12.00 | — | — | |
| — | — | — | Above/ 11100.00 Below/P | ||
| Supply and stringing of over head mains beneath platform shelters using 5 runs of 16 sq. mm PVC insulated and PVC sheathed multi stranded aluminium conductor cable duly by binding onto insulators of brackets provided vide item No. 22 above complete in a manner as directed by Section Engineer in charge at Site. Note: 1)5 runs of 16 sq.mm cable are taken as 1m for unit purpose.2)The earth wire should be lugged at both ends and has to be terminated in each MS clamp through Nuts and Bolts. | — | 60.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .