Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | ₹42.9 L Quoted ₹43.7 L | L1 | Accepted-AOC BEING LOWEST TENDER. L1 |
| 2 | L2₹44.6 L+₹90,931 (2.08%)Rejected-Finance | ₹44.6 L+₹90,931 (2.08%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹44.9 L+₹1.2 L (2.66%)Rejected-Finance 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | ₹44.9 L+₹1.2 L (2.66%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹46.4 L+₹2.7 L (6.15%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | ₹46.4 L+₹2.7 L (6.15%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹47.5 L+₹3.8 L (8.75%)Rejected-Finance 5 127 16 GANESH GARDEN KADAMPADI SULUR COIMBATORE TAMILNADU 641401 | COIMBATORE | TAMIL NADU | 641401 | ₹47.5 L+₹3.8 L (8.75%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | KUMAR AGENCIES L1 | KRISHNA ENTERPRISES L6 | Neptune Engineers and Builders L8 | CAK Enterprises L5 | D.R ASSOCIATES L2 | NLK Construction L3 | eurekaenterprises L7 | PRIYA ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | |||||||||||
| 2.00 | S&F twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed.
Make - Finolex/Havells/Standard /Finecab. | 100 | RM | 60 ₹6,000 | 75 ₹7,500 | 5,650 ₹5,65,000 | 42 ₹4,200 Lowest | 57 ₹5,700 | 63 ₹6,300 | 87 ₹8,700 | 58 ₹5,800 |
| 3.00 | S&F twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed .
Make - Finolex/Havells/Standard /Finecab. | 150 | RM | 95 ₹14,250 | 95 ₹14,250 | 125 ₹18,750 | 60 ₹9,000 Lowest | 87 ₹13,050 | 135 ₹20,250 | 130 ₹19,500 | 110 ₹16,500 |
| 4.00 | S&F twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed.
Make - Finolex/Havells/Standard /Finecab. | 110 | RM | 150 ₹16,500 | 190 ₹20,900 | 180 ₹19,800 | 90 ₹9,900 Lowest | 147 ₹16,170 | 165 ₹18,150 | 170 ₹18,700 | 180 ₹19,800 |
| 5.00 | Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 63A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand | 1 | Each | 9,500 ₹9,500 | 9,600 ₹9,600 | 9,700 ₹9,700 | 9,000 ₹9,000 | 9,000 ₹9,000 | 8,750 ₹8,750 Lowest | 9,800 ₹9,800 | 9,704 ₹9,704 |
| 6.00 | Supply and fix in replacement on-load changeover switch 415 V, 4 pole,100 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand | 1 | Each | 9,950 ₹9,950 | 10,000 ₹10,000 | 10,200 ₹10,200 | 10,300 ₹10,300 | 10,000 ₹10,000 | 9,900 ₹9,900 Lowest | 10,000 ₹10,000 | 9,925 ₹9,925 |
| 7.00 | Supply and fix in replacement on-load changeover switch 415 V, 4 pole,160 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand | 1 | Each | 11,500 ₹11,500 | 11,750 ₹11,750 | 10,650 ₹10,650 Lowest | 12,450 ₹12,450 | 11,600 ₹11,600 | 11,500 ₹11,500 | 11,700 ₹11,700 | 11,450 ₹11,450 |
| 8.00 | Supply and fix in replacement on-load changeover switch 415 V, 4 pole,200 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand | 1 | Each | 12,500 ₹12,500 | 13,250 ₹13,250 | 11,950 ₹11,950 Lowest | 13,250 ₹13,250 | 12,600 ₹12,600 | 12,700 ₹12,700 | 12,900 ₹12,900 | 12,700 ₹12,700 |
| 9.00 | Supply and fix in replacement on-load changeover switch 415 V, 4 pole,250 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand | 1 | Each | 16,500 ₹16,500 | 17,250 ₹17,250 | 17,500 ₹17,500 | 15,600 ₹15,600 Lowest | 16,600 ₹16,600 | 16,000 ₹16,000 | 16,350 ₹16,350 | 16,450 ₹16,450 |
| 10.00 | Supply and fix in replacement on-load changeover switch 415 V, 4 pole, With Sheet metal Enclosure powder coated , 320 A. Make- Havells/L&T/Legrand | 1 | Each | 18,100 ₹18,100 | 19,250 ₹19,250 | 18,325 ₹18,325 | 18,350 ₹18,350 | 18,200 ₹18,200 | 17,400 ₹17,400 Lowest | 18,400 ₹18,400 | 18,125 ₹18,125 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
7 Oct 2025, 6:00 pmClosed
GE AF
KANGAYAMPALYAM
REPAIR/MAINT OF LT ACB/MCCB, LT FEEDER PANEL/JUNCTION BOX / BUS BAR CHAMBER BOC INCLUDING CONTROL WIRING, CONTROL PANEL MCCB AND OTHER CONNECTED WORKS AT AFS SULUR
2025_MES_731395_1
8804/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please ref tender document
7 documents required · 7 mandatory
₹500
GE AF SULUR
₹90,000
19 Dec 2025
17 Sept 2025
9 Oct 2025
17 Sept 2025
7 Oct 2025
30 Sept 2025
20 Sept 2025 - 28 Sept 2025
Amount
SCHEDULE A BOQ
S&F twin core 4 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.
S&F twin core 6 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed . Make - Finolex/Havells/Standard /Finecab.
S&F twin core 10 Sqmm service wire 1100V grade heavy duty with PVC insulated aluminium stranded conductor served with inner sheatning of PVC tape and PVC sheathed including taking down old unserviceable complete all as directed. Make - Finolex/Havells/Standard /Finecab.
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 63A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,100 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,160 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,200 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand
Supply and fix in replacement on-load changeover switch 415 V, 4 pole,250 A. With Sheet metal Enclosure powder coated Make- Havells/L&T/Legrand
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, With Sheet metal Enclosure powder coated , 320 A. Make- Havells/L&T/Legrand
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, With Sheet metal Enclosure powder coated 400 A. Make- Havells/L&T/Legrand
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 16 KA, 63 Amps. Make :Havells or eqvnt of L&T/C&S/Legrand
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 25 KA, 100 Amps. Make: Havells or eqvnt of L&T/C&S/Legrand
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 25 KA, 125 Amps.Make : Havells or eqvnt of L&T/C&S/Legrand
Supply and fix in replacement MCCB, 415 volts, 3/4 pole adjustable thermal setting type 25 KA, 160 Amps Make : Havells or eqvnt of L&T/C&S/Legrand
Supply and fix in replacement MCCB ,3/4 pole,415V,36KA, 200 Amps with adjustable thermal setting. Make: Havells or eqvnt of L&T/C&S/Legrand
Supply and fix in replacement MCCB ,3/4 pole,415V,36KA,250 Amps with adjustable thermal setting.250Make: Havells or eqvnt of L&T/C&S/Legrand
Supply and fix in replacement MCCB ,3/4 pole,415V,36KA,315 Amps with adjustable thermal setting.Make: Havells or eqvnt of L&T/Legrand
Supply and fix in replacement MCCB ,3/4 pole,415V,50KA,400 Amps with adjustable thermal setting.Make: Havells or eqvnt of L&T/C&S/Legrand
Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes up to 16 sqmm 3.5/4 core ,1100 volts grade complete with jointing kit. Make: 3 M/Denson/yamuna
Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 25 sqmm 3.5/4 core to 50 Sq mm x 3.5 core,1100 volts grade complete with jointing kit. Make: 3 M/Denson/yamuna
Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 70 sqmm 3.5 core to 120 Sq mm x 3.5 core,1100 volts grade complete with jointing kit. Make: 3 M/Denson/yamuna
Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 150 sqmm 3.5 core to 185 Sq mm x 3.5 core,1100 volts grade complete with jointing kit Make: 3 M/Denson/yamuna.
Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of size 240 sqmm 3.5 core to 300 sqmm 3.5 core 1100 volts grade complete with jointing kit. Make: 3 M/Denson/yamuna
Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of size 400 sqmm 3.5 core to 500 sqmm 3.5 core 1100 volts grade complete with jointing kit. Make: 3 M/Denson/yamuna
Supplying and laying (in trenches/duct/fixing to pole/wall or in such similar position ) in replacement of extg u/s GI tubing medium grade for cable protection of following sizes:- Make: Bansal/TATA/zindal
(a) 80 mm dia
(b) 50 mm dia
(c )40 mm dia
S & F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional of the following sizes laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc complete all as specified and directed.
(a) 10 Sqmm 2 core
(b) 10 Sqmm 4 core
(c) 16 Sqmm 4 core
(d) 25 Sqmm 3.5 core
(e) 35 Sqmm 3.5 core
(f) 50 Sqmm 3.5 core
(g) 70 Sqmm 3.5 core
(h) 95 Sqmm 3.5 core
(i) 120 Sqmm 3.5 core
(j) 150 Sqmm 3.5 core
(k) 185 Sqmm 3.5 core
(l) 240 Sqmm 3.5 core
(m)300 Sqmm 3.5 core
(n)400 Sqmm 3.5 core
Excavation in soft loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engineer-in-Charge
Excavation in soft loose soil not exceeding 1.5 mtr wide and exc 1.5 mtr depth and not exc 3.0 Mtr and getting out all as specified and directed by Engineer-in-Charge
Excavation in hard and dense soil Iincluding Road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engineer-in-Charge
Returning filling soft & loose/hard & dense soil including spreading levelling, watering and well ramming in layers n exc 25 cms all as specified and directed by Engineer-in-Charge..
Removal of excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed by Engineer-in-Charge..
M&L for Riddeling Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable.
Supply and laying in replacement of cable protection cover size 250mm x 150mm x 40mm as mechanical protection to under ground cables laying across the cable as specified and directed.
M & L for cleaning vegetation around the around two/four pole structure & Panel boards area , sub stn and generator rooms etc completely root out from soil and clean the surface one mtr around the pole of street lights complete all as specified and directed. Note : Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MD land is deemed to be included in quoted rate.
S & F in repair digital Ammeter has automatic range of range from 0-250A, class 1.0,burden 15VA suitable to fix on existing LT Panel board including taking out old unserviceable item complete all as specified and directed.
S & F in repair single phase in door Current Transformer of ratio 250/5A class 1.0/5P10,burden 15VA suitable to insert on alluminium bus bar of suitable rating including taking out old unserviceable CT from existing LT Panel board complete all as specified and as directed
Attending, Repairing/restoring of electric power supply in the AF stn Sulur area, after identifying fault in HT 11 KV or LT 415 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size complete all as per specified and as directed.
Note for item No 56 :- (i) The above work also include checking, detection and rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M).
(ii) Hiring of cable fault detector to detect exact location of LT/HT UG cable fault deemed to be inclusive of quoted rate.
(iii) Major items required to be replaced/repaired will be measured under relevant items of schedule.
(iv) Excavation and earth work if required will be measured separately.
(v) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days).
(vi) In case of minor defect, entire job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300/- per hours shall be recovered.
(vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.
(viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 500/- per hours shall be deducted from the dues of the contractor.
(ix) Note that penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding.
(x) Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon and after noon to collect routine/urgent works till completion of work.
Taking down existing panel board and Design, Supply, installing testing and commissioning new of factory fabricated outdoor canopy type totally enclosed LT cubical panel board suitable size with suitable size busbar, conforming to relevant IS and protection class IP-65 ,dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 50x50x6mm MS angle iron frame, duly welded in shape including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands, Bus bar link for all outgoing MCCBs incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. (a) MCCB 4Pole 160 Amps 36 KA 415 Volt, 50 Hz (Incoming)-01 Nos (b) MCCB TPN 63 Amps 25 KA DU series of (out going) -04 Nos (c) MCB TPN 32 Amps DU series of -12 Nos (d) RYB Phase Indicating Lamps LED Type - 01 set of three (e) Digital Panel meter , VAF+PF meter 3ph class 1-5A with 3 Nos CTs of range 100/5 Amps - 01 No. (f) PCC Foundation (Civil works) for grouting of panel (g) Bus bar Minimum 400 amps or suitable size
Taking down existing panel board and Design, Supply, installing testing and commissioning new factory fabricated outdoor canopy type totally enclosed LT cubical panel board suitable size with suitable size busbar, conforming to relevant IS and protection class IP-65 ,dust, vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 50x50x6mm MS angle iron frame, duly welded in shape including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands, Bus bar link for all outgoing MCCBs incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge. (a) MCCB 4Pole 100 Amps 25 KA 415 Volt, 50 Hz (Incoming)-01 Nos (b) MCCB TPN 63 Amps 25 KA DU series of (out going) -03 Nos (c) MCB TPN 32 Amps DU series of - 2 Nos (d) Timer suitable capacity for street light- 01 No (d) RYB Phase Indicating Lamps LED Type - 01 set of three (e) Digital Panel meter , VAF+PF meter 3ph class 1-5A with 3 Nos CTs of range 100/5 Amps - 01 No. (f) PCC Foundation (Civil works) for grouting of panel (g) Bus bar Minimum suitable size
Repairing, overhauling, Servicing & testing of Air circuit breaker, 440V, 630 Amps to 1600 Amps, 50 KA, 3 Phase, 50 Hz, AC Supply system,for trouble free operation,and draw out type Air Ciruit breaker including the following works complete all as specified and directed. Location - MAFI PS 1, Sub Stn 'B' & 'D', Mehra Sub Stn, Simulator bldg, Avionic Eqpt bldg, EW block, ETB bldg, Electric logistic block, IFCS section, Mech CENGO section, Near LCA Hanger
Note for item No 59:- (a) The rate for following shall be deemed to be included in quoted rate.
(b) The entire job shall be carried out through the authorised service engineers of the OEM only.
(c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations.
(d) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the ACB trolly from the panels.
(e) Servicing of Mech and elect inter locking system.
(f) Checking and tightening control wiring and rectifying the defects if any.
(g) Servicing of Mech (caster lock) and elect inter locking system.
(h) Checking and tightening control wiring and rectifying the defects if any.
(j) Replacement of PT Fuse
(k) Replacement of unserviceable spare parts will be measured and paid for separately.
(l) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate.
(m) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only against Item No. 58 above, Electrical closing coil 230 volt AC operated all as directed.
Supply only against Item No. 58 above, Electrical shunt trip coil 230 volt AC operated all as directed.
Supply only against Item No. 58 above spring charging assembly including motor 230 V AC operated all as directed.
Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 63 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in road
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the cable size from 50 sqmm to 95 sqmm 3.5 core of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
S & F LT, Air circuit breaker, operational voltage 660 volts, insulation voltage 1000 volts, AC, 50 cycles, 3 phase, 4 pole, Electrically draw out type, rated current rating 800 amps and of breaking capacity 50 KA with quick make, quick break, with electrically operating mechanism complete with triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating “Trip Healthy circuit” ancillary switch etc complete over load release rating 400 to 800 Amps - 1 No including taking down existing one complete all as specified and as directed.
S & F in repairs Surge arrester 9 kv /10 KV suitable for Load break switch complete all as specified and as directed
M&L for preparation of old decorated surfaces of walls of LT panel plinth and applying one coat of cement based paint complete all as specified and directed.
S & F LT, Air circuit breaker, operational voltage 660 volts, insulation voltage 1000 volts, AC, 50 cycles, 3 phase, 4 pole, Manual draw out type, rated current rating 630 amps and of breaking capacity 50 KA with quick make, quick break, with manual operating mechanism complete with triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating “Trip Healthy circuit” ancillary switch etc complete over load release rating 400 to 800 Amps - 1 No including taking down existing one complete all as specified and as directed.
M&L Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (cost for copper strip deemed to be inclusive in quoted rate).
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
M & L Boring of hole under road/ hard standing by trenchless technology including S&F HDPE pipe "heavy duty" of size 100mm bore fixed in repairs complete all as specified and directed
M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 185 sqmm to 240sqmm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test complete all as specified and as directed by the Engineer-in-charge .
M&L for applying paint of LT panel board by using redoxide and synthetic enamel paint before that repairing of all damaged door hinges, locking system, beeding, damaged doors by using welding , soldering providing of new GI sheet minimum 3.15 mm thickness before that scrapping of old rusted paint than applying red oxide one coat than applying synthetic enamel paint including marking of incoming and ountgoing distibutions, cpacities of MCCBs all as specified and directed by Engr-In_Charge.
M&L for repairing of LT panel board, all damaged door hinges, locking system, Rubber beeding, damaged doors by using welding , soldering providing of new GI sheet minimum 3.15 mm thickness including provididng new locking system if damaged , earth terminals, burnt cable connections, cable protection sleeves etc all as specified and directed by Engr-In_Charge.
Material and labour for finding faults of LT under ground cable XLPE 11 KV of any size up to 400 Sqmm by using computerised / primary current injection method /any other method and locating fault .Cutting removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site complete:- Note:-(i) Excavation earth work sand cushioning PCC cover etc will be measured and paid separately under relevant items of schedule here in after. (ii) Cable joint will be measured and paid separately. (iii) Additional length of cable required at site for jointing will be measured and paid separately
S&F in replacement of Busbar chamber 4 way 100 Amps with aluminium bus bar made of sheet meta enclosure including mountin bracket etc all as specified and directed by Engr-in-Charge.
S&F in replacement of Busbar chamber 4 way 200 Amps with aluminium bus bar made of sheet meta enclosure including mountin bracket etc all as specified and directed by Engr-in-Charge.
S&F in replacement of Busbar chamber 4 way 400 Amps with aluminium bus bar made of sheet meta enclosure including mountin bracket etc all as specified and directed by Engr-in-Charge.
S&F in replacement of load line Distribution board double door 8 way TPN with suitable size bus bar factory fabricated with locking hinges and arrangement suitable for mounting of up to 200 Amps MCCB 4 pole including mounting bracket etc alla s specifed and directed by Engr-in-Charge.
S&F in replacement of MCBs/isolators capacity of 63 Amps TPN , 50 Hz 415 Volt all as specifed and directed by Engr-In-Charge.
S&F in replacement of MCBs/isolators capacity of 40 Amps TPN , 50 Hz 415 Volt all as specifed and directed by Engr-In-Charge.
S&F in replacement of earth fault switch for 415 Volt 3 phase LT distribution system fixing in ACB with control wiring of existing suitable size up to 400 Amps MCCB incomer and 800 amps ACB incomer all specifed and directed by Engr-in-Charge.
Notes for all items :- (a) Daily Collecting of complaints from JE/AGE is responsiblity of Contractor. After collecting Complaints from Complaint Register or Insturction by JE by Phone/SMS, complaint should be completed within 8 Hours of complaint receiving, Major complaints/LT panel wiring/Rewiring etc items should be completed within 02 days, if failure to rectified the deffects within given period than penalty charges 2000/per complaints will recover from the contractor (b) Minimum 01 Electrician and one helper with all tools, ladder and testing Equipment, as per the site requirement shall be provided by contractor. (c) Documents required for complaints like Stationery, Complaint Register, Slips & Site Order Book shall be provided by the contactor.(e) safety precautions shall be responsible by the contractor. (f) Contractor to comply all the respective notes of Particular Specifications attached.
D.R ASSOCIATES (BID ID -3444789)
NLK Construction (BID ID -3444912)
PRIYA ENTERPRISES (BID ID -3445204)
CAK Enterprises (BID ID -3444746)
KRISHNA ENTERPRISES (BID ID -3444170)
eurekaenterprises (BID ID -3445087)
Neptune Engineers and Builders (BID ID -3444725)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .