Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹35.7 L+₹71,097.25 (2.03%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.9 L+₹93,646.91 (2.68%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.9 L+₹5.9 L (16.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹40.9 L+₹6.0 L (17.1%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹41.9 L
EMD Value
₹83,800
Closing Date
11 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain minor and santioned works in the area of AGE B/R II under GE (N) Ahmednagar
2023_MES_589016_1
8723 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer(North) Ahmednagar
₹83,800
Yes
1 Jul 2023
12 Apr 2023
13 May 2023
12 Apr 2023
11 May 2023
25 Apr 2023
Amount
Dismantling boarding, any description, fixed in any position with nails etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for false ceiling with Vinyle faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metallized polyster foil backing with Vinyle covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturere's instructions / specification and etc complete all as specified and directed by Engineer-in-Charge
Dismantling of Single layer Mangolare pattern or similar tiles in roofing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of Asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings etc complete all as specified and directed by Engineer-in-Charge
Pre painted galvatume aluminium Manglore pattern zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas etc complete all as specified and directed by Engineer-in-Charge
Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas etc complete all as specified and directed by Engineer-in-Charge
Dismantling of stone slab & tiles of any description in floor, approx laid, bedded & pointed in any mortar etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete(un-reinforced) in ground floor & paving n.exc 15 cm thick below or above ground level etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC 1:4:8 type D-2 using 40mm graded aggregate as in sub base of floor 75mm thick etc complete all as specified and directed by Engineer-in-Charge
M&L for Vitrified Ceramic tiles coloured 10 mm thick (Square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match. and including 15 mm thick screed layer in CM 1:6 etc complete all as specified and directed by Engineer-in-Charge
All as per item No 10 (here-in-before) but on skirtting on back coat 10 mm thick in CM 1:4
M&L for Hand cut kota stone slab flooring 20-25mm thick laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) set and jointed in neat grey cement slurry and pinted with grey cement and pigment to match the shade of stone slab including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat grey cement slurry and pointed with grey cement and pigmnet to mathc the shade of stone slab including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
Material and labour 20mm thick pre-polished granite stone slab of approved shade and colour Jet Black / Telephone Black as in top table, top of WHB, kitchen slab/platform, steps, gate pillars, cills, jambs, lintel etc or on vertical surfaces including vertical projection, full round moulding the edge laid over screed bed 10mm thick in CM 1:4 jointing , pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite and rubbing polish to achieve mirror finish etc complete all as specified and directed by Engineer-in-Charge
Demolation of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete block walling etc complete all as specified and directed by Engineer-in-Charge
M&L for Brickwork with fly ash bricks, Old size bricks straight or curved on plan exc 6m mean radius, built in in CM 1:6 etc complete all as specified and directed by Engineer-in-Charge
All as item No 16 (here-in-before) but except bricks
Material and labour for Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in set and jointed in neat cement slurry laid over and incl. screedbed 15mm thick in CM 1:6 set and jointed with white or coloured cement to match complete joint free etc complete all as specified and directed by Engineer-in-Charge
Material and labour for Glazed ceramic coloured tiles in vertical surface of size 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. over and including 10 mm thick backing coat in cement mortar 1:4 etc complete all as specified and directed by Engineer-in-Charge
Complete removal of existing treatment and applying chalk whiting and two coats of OBD on walls over a coat of wall care putty etc complete all as specified and directed by Engineer-in-Charge
M&L for washing, rubbing down and stopping of distempered and painted surfaces on walls and applying two coats of cement paint on walls.etc complete all as specified and directed by Engineer-in-Charge
Preparation of old cement plastered surfaces of any description otherwise specified and applying one coat of synthetic paint etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick/stone walls or ceiling including taking out joints hacking for keys, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
Material and labour for rendering 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:4 surfaces finished even and fair etc complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of newly plastered surfaces and applying two coats of OBD over chalk whitening etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames exc 1.5 Sq m but nexc 4.00 sqm with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each etc complete all as specified and directed by Engineer-in-Charge
M&L for Anodised aluminium powder coated frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge
M&L for Anodised aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading screws etc complete all as specified and directed by Engineer-in-Charge
Supply and fix galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified and directed by Engineer-in-Charge
Material and labour for glazing with 5 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
Material and labour for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane including haching out old glasses etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified and directed by Engineer-in-Charge
Material and labour for one coats of synthetic enamel paint over old wooden surfaces of any description exc 10 cm width or girth including preparation of surfaces and smooth finish with roller etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in the same opening for easining etc complete all as specified and directed by Engineer-in-Charge
M & L for Taking up or down steel tubing 15 mm bore of pipes and connections, including cleaning for re-fixing etc complete all as specified and directed by Engineer-in-Charge
M & L for Taking up or down steel tubing 20 mm bore of pipes and connections, including cleaning for re-fixing etc complete all as specified and directed by Engineer-in-Charge
M & L for 16 mm outer dia of Pipe 3 Layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN - 16) uv stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
M & L for 20 mm outer dia of Pipe 3 Layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN - 16) uv stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fitting fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
M&L for in repairs Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) etc complete all as specified and directed by Engineer-in-Charge
S&F for in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) etc complete all as specified and directed by Engineer-in-Charge
S&F of rolled steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 (Gde-E- 250) quality-A etc complete all as specified and directed by Engineer-in-Charge
Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer for new steel or iron surfaces of any description exc 10 cm width or girth including preparation of surfaces and smooth finish with roller etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs wash hand basin vitreous China, of size 550 X 400 mm including Pedestal and a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in Soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:4:8 type D2 (40 mm graded aggregate) as in foundation, fitting and mass concrete etc complete all as specified and directed by Engineer-in-Charge
S&F for Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, etc complete all as specified and directed by Engineer-in-Charge
Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm thick 3D wood grain Moulded PVC Sheet Polyurethan etc complete all as specified and directed by Engineer-in-Charge
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix aluminium anodised barrel tower bolt of extruded section 200mm long etc complete all as specified and directed by Engineer-in-Charge
Supply and fix aluminium anodised handles of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge
M&L for Murum filling under floors or in foundation including watering and consolidation etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC (Nominal Mix) 1:2:4 type B-1 (20 mm graded stone aggregate) Slabs supported on walls, etc complete all as specified and directed by Engineer-in-Charge
Use and waste for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) rough finished flat surfaces etc complete all as specified and directed by Engineer-in-Charge
Use and waste for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc etc complete all as specified and directed by Engineer-in-Charge
Material and labour for TMT bars 6 to 8 mm dia bars, cut to length, bent to shape required including crancking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not les than 0.90 mm dia etc complete all as specified and directed by Engineer-in-Charge
Material and labour for rendering, 15 mm thick on faces of brick work / concrete work or stone masonry surfaces with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction etc complete all as specified and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid.
Material and labour for rendering 5 mm thick on fair faces of concrete surface with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid. on ceiling etc complete all as specified and directed by Engineer-in-Charge
Preparation of new Pleatered surfaces and applying two coats of cement base paint over a coat of chalk primer etc complete all as specified and directed by Engineer-in-Charge
Preparing unplastered or plastered surfaces and applying two coats of oil bound distemper including chalk whitening on wall including smooth roller finish etc complete all as specified and directed by Engineer-in-Charge
Returning , filling in including in spreading ,leveling,watering and well raamming in layers.n exc 25 cm in Rock etc complete all as specified and directed by Engineer-in-Charge
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply and fix bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No MOR 1020 A(Orintal series) of MARC or equivalent in PLUMBER, ESS-ESS
Supply and fixing stop valve cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore
Material and labour for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs rotational moulded polyethylene water storage tanks Tripal layer (cylindrical vertical with closed top) of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to irin pipr and connecting complete all as specified and directed.including float vave 20 mm bore etc complete all as specified and directed by Engineer-in-Charge
S&F PVC connections 15 mm size with Stainless steel Nuts of length 600mm etc complete all as specified and directed by Engineer-in-Charge
S&F for PVC (SWR) floor trap, plain with grating including jointing with solevent cement 75 mm bore etc complete all as specified and directed by Engineer-in-Charge
S&F for low density polyethelene pipes 32 mm bore (LDPE) of pressure rating 6 Kg/cm² laid in trenches/fixed to wall etc complete all as specified and directed by Engineer-in-Charge
Supply and fix PVC valveless, syphonic action type, flushing cistern, low level, all accesories etc complete all as specified and directed by Engineer-in-Charge
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required etc complete all as specified and directed by Engineer-in-Charge
M&L for APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application incluiding Priming surfaces and applying normal treatment (for moderate conditions), using glass fibre base bitumen felt, grade 2 etc complete all as specified and directed by Engineer-in-Charge
M&L rendering 10mm in CM 1:3 using 100% course sand on roof mixed with and including WPC @ 3% by weight of cement and finished the surface even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge Note :- Water proofing compound measered and paid separately
M&L for PCC 1:3:6 Type - C1 using 20 mm graded aggegate as in surface chanel, benching in manhole etc complete all as specified and directed by Engineer-in-Charge
M & L for Rendering 10 mm thick in cement mortar 1:4 surface finished even and smooth with setting coat on fair faces of brickwork or concrete surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC pre cast manhole cover slab in 1:2:4 type -B1 using 20 mm aggrgate incl necessary form work and set in CM 1:6, cover slabs (for man holes etc) etc complete all as specified and directed by Engineer-in-Charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed by Engineer-in-Charge
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed by Engineer-in-Charge
S&F for 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed by Engineer-in-Charge
S&F for 110 bore PVC (SWR) bends any radius etc complete all as specified and directed by Engineer-in-Charge
S&F for 75 bore PVC (SWR) bends any radius etc complete all as specified and directed by Engineer-in-Charge
S&F for 110 mm bore PVC (SWR) branch piece, double (double Y), equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F for 75 mm bore PVC (SWR) branch piece, double (double Y), equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F for 75 mm PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge
M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars 150 mm bore pipes etc complete all as specified and directed by Engineer-in-Charge
M&L for Concrete bed Cement concrete 1:3:6 type C-2 (40 mmgraded stone aggregte) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in for 150 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge
Excavating over areas, n exc 1.5m deep and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
M&L for Hardcore of Broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand etc complete all as specified and directed by Engineer-in-Charge
M&L Rough finished wooden Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC 1:2:4 nominal mix Type B1 using 20 mm graded stone aggregate as in Chajjas etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC 1:2:4 nominal mix Type B1 using 20 mm graded stone aggregate as inBeams, cantilevers, bressummers,lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge
All as per Sl item No 94 (here-in-before) but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L for PCC 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No U-0911 of PLUMBER or equivalent in MARC, ESS-ESS
Supply and fixing in repairs 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No MOR 1010(Orintal series) of MARC or equivalent in PLUMBER, ESS-ESS
M&L cast iron floor trap with grating 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 including removing old traps etc complete all as specified and directed by Engineer-in-Charge
M&L for Grating doom 100mm dia of PTMT (Minimum weight 25gms) etc complete all as specified and directed by Engineer-in-Charge
Supply and fix wash hand basin vitreous China, ovel shape wall mounted of size 450 X 300 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge
Supply and fix health faucet (hand shower) with 8 mm dia 1 m long flexible tube wall mounted / hooked etc complete all as specified and directed by Engineer-in-Charge Cat Part No 573 of JAQUAR OR ITS EQUVIVALENT IN MARC / PLUMBER all as directed.
Supply and fix looking mirror of size 600 mm X450 mm etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No C 8606 Of Parryware or equivalent in Jaquar
Supply and fix20mm dia powder coated chromium plated curtain rods including brackets etc complete all as specified and directed by Engineer-in-Charge
M&L Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only), in cement mortar 1:6 etc complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of new steel surfaces of any description exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge
M&L Forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete in CM 1:6 etc complete all as specified and directed by Engineer-in-Charge
S&F of Steel work in tubular trusses including special shaped washer conforming to IS.1161-1979 grade St.-240 etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 5 Amp / 16Amp, five in one, 5 / 15 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 4 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent in Simens/ Hager/ L&T
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack Industrial type LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
Supply and fix exhaust fan,steel body AC Single phase,230 V of size 300 m sweep with ,blades frame and louvers all as specified and directed by Engineer -in-Charge
Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
(a) LT cable10 Sqmm, 2 core.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
Returnig, filling in including spreading, levelling, watering and well ramming in layers, n exc 25 cm thick in soil etc complete all as specified and directed by Engineer-in-Charge
Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply &lay HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Cutting to existing CI/GI pipe line upto 80 /50/25 mm dia for taking connection up to 25 mm dia GI pipe including insertion of CI /GITee complete all as specified and directed including Exc & earth Work
Supply and lay in trenches/or on wall medium grade steel water tubing galvanised with all fittings and joints etc complete for following size :-
(a) 20 mm bore
Supply and fix Ball brass valves 20 mm,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule etc complete all as specified and directed by Engineer-in-Charge
Supply and fix gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for for 20 mm bore etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 49,004.76 shall be deducted from BOQ on account of schedule of credit
M/s IBEX Engineers and Contractors
OM SAI ASSOCIATES
MS. G.A. CONSTRUCTION
M/s. N D Karande
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .