Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.9 L+₹2.1 L (14.3%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹17.6 L+₹2.8 L (19.3%)Rejected-Finance KASHIJORA P O BENAPUR DIST PASCHIM MEDINIPUR | BENAPUR | PASCHIM MEDINIPUR | WEST BENGAL | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹17.6 L+₹2.9 L (19.4%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L4 | Rejected-Finance Not being L1 | |
| 5 | L4₹17.6 L+₹2.9 L (19.4%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L4 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹29,160
Closing Date
6 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) KALAIKUNDA
GE (AF) KALAIKUNDA
UPGRADATION/REFABRICATION/REPAIR/RECONSTRUCTION OF BLDG FOR HSSC SET UP AT AIR FORCE STATION KALAIKUNDA
2020_MES_374046_2
8593/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) KALAIKUNDA
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹29,160
Yes
15 Oct 2020
29 Sept 2020
8 Oct 2020
29 Sept 2020
6 Oct 2020
29 Sept 2020
29 Sept 2020 - 29 Sept 2020
60 days
Amount
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil ,complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Materials and Labour for plain cement concrete (1:3:6) Type C-1 using 20 mm graded aggregate in foundations, filling , mass concrete complete all as specified and directed.
M & L for RCC M-20 nominal mix in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-20 nominal mix in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete ,complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-20 nominal mix in chajjas,complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-20 nominal mix in beams, cantilever, bressumers, lintels over 1.5M Span,complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-20 nominal mix in columns; pillars; piers; posts; struts etc,complete all as specified and directed.
Materials and Labour for brick work with fly ash brick straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sided and soffits of plinth beams and similar works; vertical or to batter for rough finished surfaces of concrete, flat, complete all as specified and directed.
Use and waste of form work to chullah hoods, chajjas,troughs and similar items including edges for fair finished surfaces of concrete, flat, complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings , girders, bressummers, lintels, cantilevers, shelves including supports,overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, flat, complete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed.
S & F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed
S & F for Anodised aluminium door shutters with aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified.
S & F anodised aluminium window and ventilator shutters with side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified
Supply & fix double layer toughened glass 06 mm thick each glass with 12 mm air gap between 02 galsses including stainless steel spider clip and silicon putty for joining the both glasses, density: 2.42 to 2.52 g/cm3, tensile strength: 120 to 200 N/sq. mm, compressive strength: 1000 N /sq. mm, modulus of elasticity: 70 GPa fixed with aluminium section door/windows/partition etc. complete all as specified and directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Supply and fix mild steel TMT bars 5 mm dia. and over up to and including 10 mm dia. in stirrups, spacers, binders etc. cut to length, bend to shape required including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
Material and labour for 12mm thick perforated particle board/ tiles 60 x 60 cm fixed in frame of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding walls using to centre/intermediate channel 0.9 mm thick having two equal flange of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fastner with and including ceiling section (n.exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with 6 mm dia GI hangers (upto 1200 mm length) adjusting level fixed to roof slab made out of GI Flats 40x3 mm size & 60 mm long and finally painting the perforated board with two coats of synethetic enamel paint over a coat of primer complete all as specified and as directed
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn in scantlings and timber framed and fixed complete all as specified and as directed.
S & F plain fillets of 2nd class hard wood in square, rectangular or triangular in section wrought secured with screw, area exceeding 3 sqcm but not exceeding 6 sqcm complete all as specified and directed.
S & F in 12 mm thick perforated parrticles board/tiles for insulation and acoustic wall panel of size 600 mm X 600 mm, fire performance of Class B-s2, d1 - EN 13501-1:2007, insulation value (R Factor-Watts) of 1.2 m² K/W, including fixing with internal impaler hook made of metal including fixing and installation as per manufacturer’s instructions and by their approved installation agency complete all as specified and as directed
S & F Bonded mineral wool blanket slab made from glass density 24 kg/cum and fixed as per manufacturer’s instructions, 40mm thick fixed in wall and ceiling as per manufacturer,s instruction and by their approved installation agency complete all as specified and as directed
Materials and Labour for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed.
Materials and Labour for forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, with built in cement mortar(1:6) complete all as specified and directed.
Materials and Labour for making good under cills or over arches, lintels and bressummers. including all pinning when necessary with cement mortar (1:4) complete all as specified and directed.
M&L for rendering 5mm thick plaster in cement mortar 1: 3 on fair faces of concrete surfaces such as soffit of slab, beam, ceiling etc including finishing the surface even & smooth complete all as specified and directed
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Material and Labour for applying two coats of cement-based paint, white or tinted over and including alkali resistant primer to new plastered surfaces on walls,including preparation of surfaces complete all as specified and directed.
Materials and Labour for applying applying two coats of acrylic distemper, white or tinted, to new plastered surfaces on walls, over a coar primer paint and including preparation of surfaces, complete all as specified and directed..Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
S & F double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S & F exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
Glazing with sheet glass 5.5mm thick tinted ordinary quality in panels of aluminium windows, ventilator, door etc. fixed with glazing clips, rubber beading and EDPM gasket in square not exceeding 0.5 Sqm in each pane.complete all as specified and directed.
Glazing with sheet glass 5.5mm thick tinted ordinary quality in panels of aluminium windows, ventilator, door etc. fixed with glazing clips, rubber beading and EDPM gasket in square exceeding 0.5 Sqm in each pane.complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of acrylic distemper, white or tinted, to old un -decorated plastered surfaces on walls including preparation of surfaces complete all as specified and directed.
M & L point wiring for Light /fan point controlled by one switch with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised/ brass screw and cup washer complete all as specified and directed. Note : (i) Circuit wire from DB to switch board is included in unit rate of point wiring. (ii) Distance of point from switch baord up to 15 mtr to be considred as one point. (iii) Wiring to be done with FRLSH wire single core, mutistranded copper conductor and as per approved colour code in IE rule.
All as per item No. 46 here-in-before, but for 3 pin 5 amp switch socket combination on independent board complete all as specified and directed.
All as per item No. 46 here-in-before but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
All as per item No.46 here -in- before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F (3 pin and 2 pin) combined swich socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F (3 pin and 3 pin) with common earthing pins, combined switch socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S&F LED 2 X 18 Watt tube light fitting (T8 type) , including LED retrofit tube 2 x 18 W , 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make Bajaj, Cat Part Batten : BLRB DB 218, Cat Part : LED refrofit tube : or equivalent in Havells/ Crompton. Note : Batten and tube shall be of same Make.
S & F LED light fittings , recessed mounting , 600 mm x 600 mm, 36 watt, having efficient LED glare free soft illumination, white powder coated housing with LEDs, seamless front frame with flate white high tramission acrylic cover including all hanging arrangement and fixing by providing hanging chain and providing electric connection from ceiling rose with PVC insulated, PVC sheathed, 1.0 Sqmm x 3 core copper conductor cable complete all as specified and as directed by Engr-in-Charge.(Make:- Bajaj Cat No:- BZRSQL 36W Gzi WHLED (LED) equivelant in Havells / C&S / Crompton.
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door with 160 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 160 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507751 Model: (Ekinox-3) , MCCB 160 Amp Cat No. 420047, Model : DPX -3 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box will same make as approved by GE
S&F DB Box, in sheet metal enclosure VT DB TPN, MCB DB TPN 4 way, double door, with MCB as incomer, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, with provision for FP MCB as incomer and SP/TP MCB`s as out going, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507725 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box will same make as approved by GE
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 12 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507612 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507611 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F MCB SP 6-32 Amp , AC , 220 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F MCB SPN 6-32 Amp , AC , 220 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F MCB TP 6-32 Amp , AC , 415 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S & F MCB, 4 Pole, 40-63 Amp , AC , 415 Volt , 10 kA , C-curve , ISI marked, as per IEC 60898-1 2002 complete all as specified & directed.
S&F Signal Pole & Neutral enclouser with two pole and earth metel plug and socket for AC , with and including 20 Amp SP MCB, 220 Volt , 10 kA , C-curve complete all as specified and as directed by Engr-In- Charg.
S&F Tempra Plug socket DB, industrial type, Three Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with 32 Amp FP MCB (3P+N+E - FP), 415 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 P17, Cat Part No. 507862 or equivalent in Seimens/ Schinder.
S&F Tempra Plug socket DB, industrial type, Three Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with 63 Amp FP MCB (3P+N+E - FP), 415 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 P17, Cat Part No. 507864 or equivalent in Seimens/ Schinder.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete. Make of wire : L&T / Polycab/ Havells
M&L for Sub main wiring with three single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 2 x 6.0 Sqmm earth wire) . Make of wire : L&T / Polycab/ Havells
M&L for Sub main wiring with three single core PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC casing capping not less than 40 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 10.0 sqmm + 2 x 10.0 Sqmm earth wire) . Make of wire : L&T / Polycab/ Havells
S&F race way PVC casing caping of size 50 mm x 38 mm, 1 x compartment, in strandard length of 2 mtrs, including laying of cables/ wire in neat presentable condition, including fixing brackets, jointing coupler, complete all as specefied and directed by Engineer in Charge. Make Legrand Cat No. 089667 or equivalent
Supply and fixing wall mounted fan 400 mm sweep, Air delivery 72 CMM, with high speed motor of min wattage 50-55 watt, 240 V, 50 Hz, 1350 RPM, No. of speed -03 Nos, with thermal overload protector, having oscillation, up and down tilting and remote operated feature, white colour complete all as specified and directed by Engineer in Charge. Make : Havells Model Platina, or equivalent in Bajaj/ Crompton/ Usha
S&F Sheet metal one way enclouser for MCCB , suitable for accomodating 4 Pole MCCB up to rating of 160 Amp, in CRCA sheet, as per IEC 61439-3 IK 08, suitable for flush / surface mounting, complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 , Cat Part No. 507861 (DPX 3 160 MCCB enclosure) or equivalent in Seimens/ Schinder.
S&F MCCB 100 Amp, 4 Pole , 16 kA, 415 V, AC, 50 Hz, Thermalmegnetic protection, with adjustable sensitivity and adjustable tripping , Ics = 100%Icu including making all electrical connection by providing copper lugs etc .Make- Legrand, Model : DPX 3 MCCB, Cat Part No. 420005 (DPX 3 160 type MCCB ) or equivalent in Seimens/ Schinder.
M&L Flame proof concealed point wiring complete with 1.5 Sqmm FRLSH PVC insulated and unsheathed single core multistranded copper conductor cable for working voltage 1100 volts, grade drawn into and including 20 mm bore concealed steel conduit of medium grade for one light /fan point controlled by one switch including 1.5 Sqmm FRLSH PVC insulated stranded copper conductor cable for earth continuity conductor and connecting to earth dolly all as specified and directed by Engineer-in-Charge for one light, fan point controlled by one switch. Note:- (i) The chases in the wall shall be cut with elect cutter will be deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charg
S & F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as directed by engr-in-charge.
Supply and filling in approved dry sand in cable trenches before and after the cables are laid, as in sand cushioning to cables, complete all as specified and directed.
Supply and laying common burnt clay building bricks, sub-class ‘B’ designation 75, old size bricks, in cable trenches, as cable protection, complete all as specified and directed.
M&L for laying 80 mm bore GI pipe, light grade with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for laying 50 mm bore GI pipe, medium grade with all fittings, in crossing road/path and in pole/wall up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.(Note : Boring under road/path will be measured and paid under respective item )
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 sqmm 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends. Make: Polycab/ Havells/ KEI.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded,armour galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends Make: Polycab/ Havells/ KEI.
Supply, Laying, commissioning and testing of LT power cable, XLPE insulated, screened, PVC bedded, inner sheathed, armoured, galvanized steel strip armoured, electric power cable (heavy duty), 1100 volts grade with stranded copper conductor of size 50 sqmm x 3.5 core including connecting the cables at both ends by providing suitable size copper lugs at the termination ends Make: Polycab/ Havells/ KEI.
S&F Sheet metal one way enclouser for MCCB , suitable for accomodating 4 Pole MCCB up to rating of 250 Amp, in CRCA sheet, as per IEC 61439-3 IK 08, suitable for flush / surface mounting, complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 , Cat Part No. 507802 (DPX 3 250 MCCB enclosure) or equivalent in Seimens/ Schinder/ L&T.
S&F MCCB 250 Amp, 4 Pole , 36 kA, 415 V, AC, 50 Hz, Thermal adjustable type, having adjustable overload and short circuit protection, Ics = 100%Icu including, spreaders terminals, phase barriers, making all electrical connection by providing copper lugs etc. Make- Legrand, Model : DPX 3 250 MCCB, Cat Part No. 420248 (DPX 3 250 type MCCB ) L& T Model No. CM92109OOP10G or equivalent in Legrand / Seimens/ Schinder.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 400 Amps ( Size of copper strip should not be less than 40 x 6 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following.
(A) Incoming (i) MCCB 250 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 200-250 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos with rotatary handle (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp (v) Neon type for three phase. (vi) Slector switch - 2 Nos (B) Outgoing (i) MCCB 160 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 125-160 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 02 Nos with rotatary handle(ii) MCCB 100 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 80-100 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 25 KA - 01 Nos with rotatary handle. (ii) MCB 40 Amp Four Pole (FP) , ultimate Note:- (i) All MCCB/MCB should be of Make : L&T/ABB/Schnider. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Cost included taking out existing cable from old panel and refixing and connecting to new panel. (v) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vIi) The copper extesion link from bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders
M&L Earthing complete with copper earth plate electrode 600mm x 600mm x 3 mm thick burried direct in ground (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to copper strip 20 X 3 mm as earth lead by means of bolts nuts, check nuts and washers of glavanised iron and as shown in electrical plate No 3 connected to earth test point including necessary excavation in hard dense soil and refilling of earth pit after placing the electrode with agriculture soil, removal of existing excavated soil upto a distance of 100m, RCC chamber cover plate, wire mesh, funnel, test point, 40 mm dia GI protection pipe medium grade and separate pipe of 40 mm dia medium grade GI pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately. ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit and rate shall be deemed to be included in quoated rates
M & L for copper earth contInuity conductor of size 20 x 3 mm strip with insulator fixed to wall or drawn in conduit/pipe as required all as directed by Engineer In charge. Note: Insulator to be fixed on every 50cm distance and cost of insulator is deemed to be included in unit rate of item.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth lead wire 4 mm dia. by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced 8 mm dia TMT bars @ 150 center to center both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part –I .(Note: (i) Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) (ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit and rate shall be deemed to be included in quoated rates
S&F for Test point junction box made of polycarbonate without terminal block 130x130x77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation. Make : Hensel- Cat part No. KF 0600 H
S & F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and as directed.
M/S C C CONSTRUCTION
M/S Tapan Sur
M/s Tekcon International
SUMAN CONSTRUCTION
SENCO
JEETEN ENTERPRISE
SHARMA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .