Superintending Engineer
Superintending Engineer, PWD, Heritage Buildings Circle, Chennai-05
Providing Additional amenities, External and Internal Electrification, Air Conditioning arrangements and on Grid Solar Power plant in Archelogical Museum at Keeladi in Sivagangai District.
2024_PWD_508761_1
17/HBC/2024
Open Tender
Electrical Works
Lump-sum
90 days
Sivagangai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹75,000
Yes
28 Mar 2025
7 Dec 2024
23 Dec 2024
7 Dec 2024
23 Dec 2024
7 Dec 2024
Amount
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) (SD-281)
supply and fixing of 1200mm (48") sweep AC ceiling fan Havells make Stealth Air ES Rosewood model/Equivalent Make complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18") (DATA-1)
Supply and fixing of 32 A DP MCB switch in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection (DP MCB & METAL Enclosure should be of (Higher end).(DATA- 2)
Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed FRLS Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 Sq.mm copper wire with painting of suitable colour.(SD-56)
Supply and run of 2 of 6sqmm (56/0.3) PVC insulated SC unsheathed FRLS Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6 Sq.mm copper wire with painting of suitable colour.(SD-58)
Supply and run of 4 of 6sqmm (56/0.3) PVC insulated SC unsheathed FRLS Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6 Sq.mm copper wire with painting of suitable colour.(SD-62)
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming, 1 Nos 63A 4 pole RCCB and 12 nos. 6A to 32A SP MCB as outgoing on wall with Suitable earth connection only. (Higher End) (DATA-3)
Supply and fixing of 8 way vertical TPN MCCB DB with metal door cover with IP 43 protection (SPECIAL TYPE) with 1 no 160A FP MCCB as incoming and 4 No 63A TP MCB, 2 No 32A TP MCB,6 Nos 6A-32A SP MCB as outgoing on wall and Suitable angle iron frame work and cable entry box with earth connection. (The MCB DB, and MCBs should be Higher end).(DATA-4)
Supply and laying of 3 ½ x 150 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-188)
Supply and clamping of 3 ½ x 150 sq.mm PVC LTUG armoured cable in a cable tray or on wall with MS Clamps.(SD-206)
Supply and fixing of brass cable gland for 3 1/2 x 150 sq.rnrn LTUG armoured cable with earth connection.(SD -170 )
Supply and providing cable end termination of 3 1/2 x 150sqmm PVC LTUG Aluminium armoured cable withnecessary aluminium cable sockets by crimping etc. with electrical connection comple) (SD - 219)
Supply and laying of 3 ½ x 35 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-183)
Supply and clamping of 3 ½ x 35 sq.mm PVC LTUG armoured cable in a cable tray or on wall with MS Clamps.(SD-201) (Lift)
Supply and fixing of brass cable gland for 3 1/2 x 35 sq.rnrn LTUG armoured cable with earth connection.( SD - 165)
Supply and providing cable end termination of 3 1/2 x 35sqmm PVC LTUG Aluminium armoured cable withnecessary aluminium cable sockets by crimping etc. with electrical connection comple) (SD - 214 )
Supply and laying of 3 ½ x 25 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-182)
Supply and clamping of 3 ½ x 25 sq.mm PVC LTUG armoured cable in a cable tray or on wall with MS Clamps.(SD-200)
Supply and fixing of brass cable gland for 3 1/2 x 25 sq.rnrn LTUG armoured cable with earth connection.( SD - 164 )
Supply and providing cable end termination of 3 1/2 x 25sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection comple) (SD - 213 )
Supply and fixing of 100W LED Flood light luminarie with ultra sleek made of pressure die- cast aluminium housing with suitable angle iron work comlete on Entrance Arch with painting of suitable colour.(Havells make) (Data-5)
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.( SD - 211)
Supply and run of 1 of No.8 SWG Copper wire covered with Suitable PVC pipe for earth connection.( DATA - 6)
supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour.(SD - 456)
Supply and laying of 4x16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-181)
Supply and clarnping of 4 x 16 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD-199)
Supply and fixing of brass cable gland for 4x25 sqmm PVC armoured LTUG cable with earth connection.(SD-163)
Supply erection testing and commissioning of 2TR (6000 K.cal/hr) plastic split type Air conditioner filted with rotary high efficiency compressor opearating on refrigerant R32/R410A suitable for wall mounting for opearation on 230v 50HZ single phase AC supply with star ratting of 3 as per BEE specification and capable of performing the function.(1) Cooling (2)Dehumidifying (3) Air circulation (4) Filtering This installation works for the above split type AC units including the following (1) Mounting /Fitting Indoor and Outdoor units at their respective Locations. (2) Laying refrigerant pipe line of required length connecting both units after drilling hole/ holes in the wall if required. Thickness of the copper tubing shall not be less than 0.8 mm (3) Insulating the suction pipe with expanded polyethylene foam 5mm tubing. (4) Laying 1.5mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.(5) Leak testing the entire system unit. (6) Charging refreigerantgas in the unit. (7) Suitable electric wiring to be provided with in 2.5sq.mm PVC insulated copper wire between indoor and outdoor units upto 6 mtrs length and upto switch within 3 mtrs of location of indoor unit. (carrier/Voltas /Blue star/equ) (SR- 2024-25)
Supply and Installation of 5KVA electonic automatic voltage stabilizer V-Guard make VGS 500 with high and voltage cut off and 3 miniutes time delay relay with demonstration. (SR- 2024-25)
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit). (SR- 2024-25)
Supply and fixing of MS stand for fixing Spilt Airconditioner Outdoor Unit.(SR- 2024-25)
Supply and fixing of 200 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD Earthing.(SD- 636)
Supply and fixing of 63A FP MCB isolator switch in sheet steel enclosure on wall and making good of the earth connection (FP MCB & METAL Enclosure should be of Higher end).(DATA- 7)
Supply and fixing of 32A FP MCB switch in sheet steel enclosure on wall and making good of the earth connection (FP MCB & METAL Enclosure should be (Higher end).(DATA- 8)
Supply and fixing of 6A - 32A SP MCB switch on existing DB with earth connection (MCB should be Higher end).(DATA- 9)
Supply and fixing of 125A MCCB switch on existing DB with earth connection (FP MCB & Metal should be of Higer end).(DATA- 10)
Supply and laying of 3 Core *2.5 sqmm copper round cable ina trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refitting the earth make good. (DATA-11)
Supply of floor standing type (Carrier Midea)/Blue star/Voltas/equivalent) air conditioners unit 4tr nominal capacity consisting of 1No of Indoor unit with cooling coil section,blower section with motor,filter section and 1 No of 4TR Outdoor unit consisting of Scroll/Rotary compressor 400v+/-10% 50Hz,3Phase,3 wire AC Power supply with Microprocessor Control.(Q)
Installatio,testing,commissioning charges for 4TR Slimpack unit (Q)
Supply and fixing of 19.1mm copper refrigerant pipe.(Q)
Supply and fixing of 9.5mm copper refrigerant pipe.(Q)
Supply and laying of Drain pipe 32mm.(Q)
Supply and run of 2.5 Sq.mm x 4 core cable from outdoor units to indoor unit inter connection wire.(Q)
Supply and providing of pipeline nitral rubber insulation for section line refrigerant pipe and PVC pipe as required
Supply and fixing of Indoor unit stand
Supply and fixing of Outdoor unit stand
Supply and fixing On Grid Solar PV Plant (10KW) comprising of: i) Solar panels of type Mono Crystline, PERC, etc. ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, Protection Devices, Interconnecting D.C. cables, Connectors, Junction Boxes and accessories. iii) D.C. D.B iv) A.C. D.B v) A.C. cables and accessories vi) Lightning arrestor, earthing, etc. vii) Module Metallic Mounting Structures viii) Installation, Testing and Commissioning corresponds to BIS and IEC requirements
Supply and fixing of Plot /POOL LED light fitting with 3W,IP-68,3000K (K-Lite/Equivalent) with mounting screws and brackets and conduit pipe suspension from terminals to the fitting.
Supply and fixing of LED Bollard light fitting with16W,IP-44,3000K (K-Lite/Equivalent) with mounting screws and brackets with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of LED Architectural landscape light fitting with 50W, IP-68,300K (K-Lite/Equivalent) with mounting screws and brackets with PVC unsheathed copper leads from terminals to the fitting.(Lawn).
Supply and fixing of LED Architectural Spot LED light fitting for roof up lighting with 36W,CRI<80,IP-65,3000K (K-Lite/Equivalent) with mounting screws and brackets and conduit pipe suspension from ceiling with PVC unsheathed copper leads from terminals to the fitting.(K-LiTE)
Supply and fixing of 32A DP Modular Switch with indicator- module suitable MS Box.(Data-6)
Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End.(Sd-385)
Supply and fixing of Uplight 10W LED Light With waterproof arrangements(Model Number KL4092 K-Lite/Equivalent Make)
Supply and fixing of Driver and Lamp in the existing K.LITE/Equivalent make Post Top Lantern fitting and giving connection etc., (DATA-12)
Supply and fixing of Driver and Lamp in the existing Twin Wall fitting and giving connection etc., (DATA-13)
EARTHING: Supply and installation and maintenance free GI earthing system comprising of 50mm dia and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs.of carbon based environment fridendly backfill compound and suitable clamp.(PV Module structure components shall be electrically interconnected and shall be grounded. Earthing shall be done accordance with IS 343-1986.A minimum of two separate dedicated and interconnected earth electrodes must be used for the earthing of the solar PV system support structure with a total earth resistance not exceeding 5 Ohm.(Market rate)
ANNAI ELECTRICALS (BID ID -1215629)
SASTHA ELECTRICALS (BID ID -1215685)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_605147.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .