GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
COMPLETION OF BALANCE WORK AT RISK AND COST AGAINST PROVN OF DUCTABLE AC FOR BLOOD BANK OF AFTC, PROVN OF 08 X 1.5 TR CAP SPLIT TYPE AC FOR PSYCHAITRY WARD AND MAINT OF U/S SPARES OF VOLTAGE STABILIZER, UPS AND OTHER MISC E/M WORKS AT BASE HOSPITAL
2020_MES_344880_2
GE/BH-19/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹49,000
Yes
28 Jul 2020
24 Jun 2020
17 Jul 2020
24 Jun 2020
15 Jul 2020
1 Jul 2020
Amount
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil all as specified
Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil all as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:-Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand only will be considered.
Supply and laying common burnt bricks of sub class ‘B’ laid flat at right angle on the cable complete all as directed in trenches for cable protection complete all as specified and directed
S&F in repair for earth continuity conductor or main earthing strip fixed to wall/ chases or buried in ground or drawn in conduit (pipe/fixed to poles) of any type or any other situation for loop earthing etc with GI strip of size 25 X 4mm complete all as specified by Engg-in-charge
Material & labour in replacement for 80 mm dia bore GI steel tubing light grade for protection of cable / earth continuity conductor fixed to poles / walls / roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and washer etc including taking down old pipe complete all as specified and directed.
Dismantling carefully voltage stabilizer of any size and capacity and material and labour for complete overhauling of the burnt windings of the voltage stabilizer with copper winding of suitable gauge including refixing, connecting, testing and commissioning the stabilizer including carrying out on load test after rewinding of voltage stabilizer complete as specified and directed by Engr-in-Charge.
Dehydration / filtration of voltage stabilizer oil of voltage stabilizer of various capacities installed at different locations in base hospital by disconnecting plants electrically for recirculation existing voltage stabilizer oil with trolley mounted filtration plant till dielectric strength is up to 45 KV to 50 KV. Note- Quoted rates shall be deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) Transformer oil for topping up will be measured and paid in relevant item as required.
Supply & topping up of oil for voltage stabilizer up to required level for voltage stabilizers of dielectric strength 50 KV & above all as per IS specification.
M&L for painting of voltage stabilizer after cleaning the body surface of panel by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint incl writing SM No/MES No as per existing pattern complete all as specified and directed by Engineer-in-Charge
Dismantling and removing of defective voltage stabilizer of following size and capacity, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and re-assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. : The job also incl. shifting through crane with necessary accessories & to and from transportation from site to work shop and vise- versa. Note 3. : Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately under item No 16 to 27.
Do above item No 15 capacity 50 KVA Voltage Stabilizer
Do above item No 15 capacity 60 KVA Voltage Stabilizer
Do above item No 15 capacity 75 KVA Voltage Stabilizer
Do above item No 15 capacity 100 KVA Voltage Stabilizer
Do above item No 15 capacity 120 KVA Voltage Stabilizer
Supply in Replacement Protection alarm circuit incorporation with features of High & low voltage, Overload, Single phasing, Phase reversal protections etc for following size and capacity voltage stabilizer.
Do above item No 16 capacity 50 KVA Voltage Stabilizer
Do above item No 16 capacity 60 KVA Voltage Stabilizer
Do above item No 16 capacity 75 KVA Voltage Stabilizer
Do above item No 16 capacity 100 KVA Voltage Stabilizer
Do above item No 16 capacity 120 KVA Voltage Stabilizer
Supply only in replacement of Sensing Trigger Transformer of reputed make as directed by engineer- in charge for following size and capacity voltage stabilizer
Do above item No 17 capacity 50 KVA Voltage Stabilizer
Do above item No 16 capacity 60 KVA Voltage Stabilizer
Do above item No 17 capacity 75 KVA Voltage Stabilizer
Do above item No 17 capacity 100 KVA Voltage Stabilizer
Do above item No 17 capacity 120 KVA Voltage Stabilizer
Supply only in replacement control wiring and electronic circuit to controls servo motor and other electronic equipment including necessary wires and cables required as per OEM recommendation complete testing on site all as specified and directed by engineer in charge for following size and capacity voltage stabilizer
Do above item No 18 capacity 50 KVA Voltage Stabilizer
Do above item No 18 capacity 60 KVA Voltage Stabilizer
Do above item No 18 capacity 75 KVA Voltage Stabilizer
Do above item No 18 capacity 100 KVA Voltage Stabilizer
Do above item No 18 capacity 120 KVA Voltage Stabilizer
Supply only in replacement of Dimmer of reputed make as per OEM recommendation complete testing on site all as specified and directed by engr-in-charge for following size and capacity voltage stabilizer.
Do above item No 19 capacity 50/60 KVA Voltage Stabilizer
Do above item No 19 capacity 75 KVA Voltage Stabilizer
Do above item No 19 capacity 100 KVA Voltage Stabilizer
Do above item No 19 capacity 120 KVA Voltage Stabilizer
Supply only in replacement of internal torque motor of voltage stabilizer of reputed make as per OEM recommendation complete testing on site all as specified and directed by engr-in-charge for following size and capacity voltage stabilizer
Do above item No 20, 3 kg. CM torque motor for voltage stabilizer
Do above item No 20, 10 kg. CM torque motor for voltage stabilizer
Supply only in replacement of Micro switches of reputed make.
Supply only in replacement of Carbon Brush of respective requirement according to voltage stabilizer of reputed make.
Supply only in replacement of Voltmeter of reputed make.
Supply only in replacement of Ammeter.
Supply only in replacement of Potentiometers
Supply only in replacement of Neon Indicators
S & F in repair Handy and light weight remote control for patients with remote with jacket to fix mount on wall and having Battery type: 12volts DC / 23A & Range indoors: 20-30 meters Model No.(FBX521) in FORBIX SEMICON or equivalent in Honeywell/ Hochiki.
S & F in repair 3-digit receiver display Operates on 12VDC (comes along with 220-110VAC converter) having display size of extra large alphabets make : - Model No.FBXCSL03A in FORBIX SEMICON or equivalent in Honeywell/ Hochiki.
S & F in repair Repeater booster enhances the range of signals furthermore high power repeater provides additional 50-60meters and additional repeater improves the signal to noise ration (SNR), at some multiple repeaters in series are required. Make :Model No.(FBXCSRPT02) Signal booster repeater in FORBIX SEMICON or equivalent in Honeywell/ Hochiki.
S & F in repair Power supply adapter converter of input as 220vac to 12v dc as out put
1. M and L for annual comprehensive maintenance of 30 KVA - 2nos. UPS system installed at dialysis centre at base hospital during the period of contract every month. Contractor also displays his contract number near UPS and complaint shall be attended within 24 hours. after completion of the same complaint contractor inform to the concerned JE E/M for fault rectification, which will be done by contractor and also recee to be done for functioning of UPS and rectifying the defects:- 2. The contractor includes maintenance of 2 nos. Online UPS inclusive of parts required in case of damage to the system namely:- (a) IGBT's, power components:- transistors, capacitors, diodes, SCR etc. (b) Contractor include maintenance and charging and also include the replacement of battery if required.( if battery replaced battery to be deposited to MES store.) Note:- 1. Primitive maintenance of system on monthly basis and up keeping the log book. 2. Attending to all the complaints within 24 hours. 3. Field service report will be maintained and submitted to JE after every month checking. 4. Maintenance of battery to be carried out on regular basis by cleaning and applying petroleum jelly. 5. In case contractor fails to attend and rectify complain within 24 hours, penalty will be enforced Rs 2000/- per complaint.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507610 or equivalent in Siemens / Schneider (Acti-9).
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507611 or equivalent in Siemens / Schneider (Acti-9).
S & F MCB SP 240 Volts, 16 to 63 Amps complete all as specified and directed. Make- Make-Havells/Legrand/Crabtree
S & F MCB SPN, 240 Volts, 32/40/63 Amps complete all as specified and directed. Make-Havells/Legrand/Crabtree
M & L Sub main wiring using two single core PVC insulated FRLS cable 4 Sqmm copper conductor multi stranded and 4.0 Sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 4sqmm copper FRLS cable & one run of 4.0 Sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L Sub main wiring using two single core PVC insulated FRLS cable 6 Sqmm copper conductor multi stranded and 6.0 Sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 6 Sqmm copper FRLS cable & one run of 6.0 Sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
Supply, erection, testing & commissioning of Air-cooled type Air conditioner 40000 Btu/ Hr capacity of cooling capacity @ +4°C Room temperature at 45 °C Ambient Temperature corrosion proof of Make Blue Star ,Model NO :- RUAHI-4014-N for indoor and RUAHOS -4014 for outdoor unit ,with Control panel model No :- CBCL-B027 -00 for operate two machine with charged Gas of R404A, Controller and power panel, Control and power cabling between indoor to outdoor unit as recommended by manufacturer, suitable size Copper tubing from indoor to outdoor unit in any length etc or equivalent in Carrier, Hitachi, Voltas with following Technical specifications :- The unit should built in with controller specially designed for refrigeration applications , Controls compressor cut off and temperature , BMS Connectivity SMS alert and statues monitoring etc. TECHNICAL SPECIFICATION OF INDOOR UNIT: Model of Indoor Unit :- RUAHI-4014-N power Supply :- 230/1/50 Air flow :- 5200 CFM Air Throw :- 40 Feet Number of circuit :- 01 Over all dimensions :- 1710 x 645 x 720 mm ( (W X D X H) Dry Weight :- 82 KG TECHNICAL SPECIFICATION OF OUTDOOR UNIT: Model of Outdoor unit :- RUAHOS-4014 Compressor type :- Hermetic Scroll Power supply :- 415/3/50 Compressor Quantity :- 1 No of Such Chassis :- 1 Over all Dimensions :- 1100 x 444 x 1259 mm ( W x D x H) Dry Weight :- 130 KG
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AFTC blood bank centre), refixing of same AC at new location with all accessories complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers. (b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer. (c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) concealing of refrigerant pipe with 80 mm dia PVC flexible pipe.
Supply and fix Copper tubing of size 3/8" suitable for split AC of any capacity with PVC insulation all around the pipe as per copper pipe size all as specified and directed by Engineer -in-charge
Supply and fix Copper tubing of size 5/8" suitable for split AC of any capacity with PVC insulation all around the pipe as per copper pipe size all as specified and directed by Engineer -in-charge
M & L submain wiring using four run PVC insulated FRLS Copper conductor 10 Sqmm with rigid non metallic PVC conduit of size 32 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc. Note four runs of 10 Sqmm copper FRLS cable & one run of 10 Sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit.
S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 8 way with 200 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 507747 or equivalent in Siemens/ Schneider (Acti-9).
S &F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507612 or equivalent in Siemens / Schneider (Multi-9).
S & F MCB TPN 63 Amp complete all as specified and directed. Make - Havells/Legrand/Crabtree
S & F MCB TPN 100 Amp complete all as specified and directed. Make - Havells/Legrand/Crabtree
M&L for Boring of holes 100 mm dia under taxi track / road pavement hard standing by trenchless technology using latest technique and necessary machine and inserting PVC pipe of 100 mm dia up to full length of bore all as specified and directed by Engg -in-charge.
Supply and fix Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over one coat red oxide primer.
Flint India
Saini Enterprises
Vishal Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .