Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.0 L+₹2.3 L (6.90%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹39.9 L
EMD Value
₹80,000
Closing Date
22 Aug 2022, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2022_MES_540371_1
87317/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AHMEDNAGAR
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE SOUTH AHMEDNAGAR
₹80,000
Yes
27 Sept 2022
23 Jul 2022
24 Aug 2022
23 Jul 2022
22 Aug 2022
8 Aug 2022
24 Jul 2022 - 1 Aug 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
All as per item No 01 above but in hard soil or bituminous road / hard standing
All as per item No 01 above but more than 1.5 m and upto 3 m
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
Supply and lay HDPE PIPE (PE 100,SDR-21,6 Kgf/Cm^2) IS 4984-2016) 110 mm dia for laying of HT cables etc complete with all accessories all as specified and directed.Make:Vectus industries/Supreme/Infra.
Supply, laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 11000 Volts grade lay in trenches, ducts, along pole, along Transformer cross sectional area of size 95 Sqmm 3 Core complete including tanking down old cable all as specified and directed by Engr-in -Charge.
Supply, laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 11000 Volts grade lay in trenches, ducts, along pole, along Transformer cross sectional area of size120 Sqmm 3 Core complete including tanking down old cable all as specified and directed by Engr-in -Charge.
M&L for HT Cable end termination box suitable for 11000 Volts grade 50 to 95 Sqmm 3 Core XLPE 11KV cable, outdoor, heat shrinkable type with all accessories complete all as specified and directed.
M&L for HT Cable end termination box suitable for 11000 Volts grade 120 to 185 Sqmm 3 Core XLPE 11KV cable, outdoor, heat shrinkable type with all accessories complete all as specified and directed.
M&L for HT Cable end termination box suitable for 11000 Volts grade 120 to 185 Sqmm 3 Core XLPE 11KV cable, indoor, heat shrinkable type with all accessories complete all as specified and directed.
M&L for HT Straight through cold shrink type joint for 11000 Volts grade 50 to 95 Sqmm 3 Core XLPE 11KV cable, outdoor, cold shrinkable type with all accessories complete all as specified and directed.
M&L for HT Straight through cold shrink type joint for 11000 Volts grade 120 to 185 Sqmm 3 Core XLPE 11KV cable, outdoor, cold shrinkable type with all accessories complete all as specified and directed.
M&L for 80 mm bore GI pipe light grade for cable protection ISI marked with all fixing accessories such as 40 x3mm Clamps of suitable length, Nut bolts and washers and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr -in -Charge.
M&L for boring holes under road, pavement hardstanding by trenchless technology using ultra sound technique & necessary machine complete all as specified and as directed by Engineer-in-Charge.
Dismantling steel poles/ struts, any size.
Supply, install and errect of true vertical steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm, finial taper plug, pole cap, bolts, nuts, washers & screws as specified type 410 SP-55 (11 mtrs long). Made out of ERW MS tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc painting with one coat red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminoius paint for portion embedded in concrete. Painting three black/red/ bands at lower portion of pole of 300mm height at 300 mm spacing, painting pole No with black paint at suitable height, complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregates for foundation of poles/posts etc.
M&L For PCC 1:3:6 type C2 using 40 mm graded aggregates for stays.
M&L for PCC 1:3:6 type C1 using 20 mm graded aggregates for coping of poles, rounded or chamfored edges including necessary for work.
Supply & Fixing GI strip of size 32 x 6 mm buried in ground/fixed to pole, wall including fixing clamp made out of 40x5 mm MSFI nut, bolt and washers complete including taking out old GI strip all as specified and directed by Engr -in -Charge.
Dismantling cross arms MS Channel or angle section etc complete all as specified and directed.
Supply and fix cross arms. bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed by Engr-in-Charge.
Dismantling/Taking out stay assembly of any descripiton keeping a side for further disposal as directed.
M&L Stay assembly comprising of 20 mm dia stay rod 2150 mm long, loop type insulator of size 90 mm x 140 mm, galvanised stay plate 6mm thick of size 300 mm x 300 mm, stay bow, stay clamps etc. complete all as specified and directed & shown in EP No. 1 of SSR Pt I. Note : Excavation, earth work and PCC shall be measured and paid seperately.
M&L for Galvanised stay strand 7/4 mm complete all as specified and directed.
Dismantling HT insulator any type any size complete all as specified and directed.
M&L Disc type insulators, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly suitable for 11000 volt grade supply.
Supply and fixing 11 KV grade pin type insulator of 150mm height, 150mm dia complete including spindle, washers and etc all as specified.
Supply and fix in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT pole of 25x20 cm size
M & L for Preparing surfaces of HT pole/two pole structure/four pole structure including cross arms, channels, clamps etc by scrapping old paints and applying one coat red oxide primer and two coats of aluminium paint and writing "HT" and Pole No in black paint etc complete all as specified and directed by Engr- in -Charge.
M & L for replacement of jump connection of two/four pole structure by using ACSR conductor weasel, alkathine pipe ,aluminium lugs, nuts, bolts etc. all as directed by Engineer-in-charge. Note:Rates includes Conductor, Pipes, Lugs, Nutbolts etc.
M&L in replacement of anticlimbing device spikes type fabricated out of MS bars (round, square and flat) incl nuts, bolts, washers and welding in two halves made to shape of the pole with two thick coat of aluminium paint complete all as specified by the Engineer in charge.
M&L for dismantling air break GOD set vertical/ horizonatal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc by replacing stationary and moving contacts adjusting from ground level for smooth operation by replacing flexible copper strip, insulators, nuts, bolts, washer, GI pipe handle etc, all as directed by Engineer-in-charge. (Note- stationary moving contact, post insulator, GI pipe and handle shall be measured & paid separaletly).
Supply and fixing in replacement of GOD handle with locking strip and insulation sleeve complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of GI pipe 25 mm dia "medium grade" 6 metre in length complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of stationary/ moving contact set for GOD complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of post insulator 11 KV for GOD complete all as specified and directed by Engr-in-Charge.
Lobour only for cleaning of bushes /small plants up to root level aruound and surrounding area E/M installations (i.e two pole / four pole structures,out door substation yards,pump house & misc E/M installations etc) including surface dressing n.exc 15 cm deep and removing debris to distance n.exc 50m complete all as specified and directed by Engr-in-charge.
Supply, fixing, testing and commissioning in replacement of air break gang operated device, triple pole mechanically operated outdoor type, mounted on and including 11 KV H.T. porcelain insulators and steel channel frame, GI operating rod, 25mm dia of suitable length with operating mechanism working from ground level, vertically operated including locking arrangement for operating handle, suitable for current rating upto 200 Amp, 11000 Volts working pressure all as specified and directed by Engr-in -Charge.
Supply and fix in replacement of dropout fuse unit explusion type for outdoor air break swirch (GOD) single pole, mounted on and including insulators for 11000 Volts working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line tabs and suitable for current carrying capacity upto 200 Amps only all as specified and directed.
Material and labour for stone aggregate 40mm graded spreading and leveling around 2 pole/ 4 pole structure where GOD installed and substation Area including well ramming with two layers of 50 mm thickness complete taking out old unserviceable aggregate stone of any size all as specified and directed by Engr-in-Charge.
M&L in replacement of Lightening arresters expulsion type complete with all fittings, transsmision class, discharge capacity 65 kilo amps, suitable for 11000 Volts all as directed by Engineer-in-charge.
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground in any type of strata (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
Dismantling of ACSR conductor including stringing, binding, jointing, jumpering etc on insulators on poles complete all as specified and directed.
M & L for Aluminium conductor steel reinforced, any size, (Weasel/Ferret/Squirrel as required) including stringing, binding, jointing, jumpering etc on insulators or on poles with minimum sag complete all as specified and diercted.
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Supply and fix GI contineous earth wire 4 mm dia (8 SWG) running on poles of HT Over head feeders, stringing, stretching, tightly connecting properly and binding to cross arms hooks etc with and including 22 SWG GI binding wire for earth continuity complete with all nuts, washers etc all as specified and directed.
Labour only for restringing/restretching of HT OH line by replacing pin binding with new aluminium conductor and maintaining sag within permissible limit for 3 runs of ACSR conductor. Note :(i) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job (ii) Any damage cause due to contractormen will be rectified without any extra payment.
Lobour only for trimming of tree branches touching to the HT over head line or near to the HT over head line as per the direction of AGE E/M/ JE incharge complete including removing the tree branches. Note :(i) Span from one pole to next pole (30 to 50 RM) will be considered as a one Span. (ii) Any damage cause due to contractormen will be rectified without any extra payment (iii) T & P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor.
Material and labour required for locating fault on low/highvoltage power cables up to 11 kv complete by using fault detector machine including transportation ,materials and all accessories,Tools and by carring out high pressure test all as directed by Engr-in-charge . (Note:Excavation ,earth work and materials ( cable,joint kits) required for fauts clearing shell be measured and paid separetely under relevant items)
M & L for pole Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground in any type of strata (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. Note: These earthings shall be provided for poles; without provision of concrete earth pits.
Material and Labour for dehyderation, filtration and cleaning of transformer oil, both indoor/outdoor/ pole mounted/plinth mounted HT switch gear etc at different locations by suitable dehgydration plant testing of oil sample before and after dehydration for each transformer/equipment and results of transformer oil dielectric strength minimum upto 42 KV , recorded jointly by contractor and Engineer-in-Charge complete including all necessary tools, plants, transportation etc all as specified/directed by Engineer-in-Charge. Note : Oil for toping up/fresh fill shall be measured and paid seperately under relevant item.
Supply & filling of transformer oil in transformer in situ/ at site for toping up the level of oil having dielectric strength 40-60 KV during filling after initial filtration conforming to IS-335 of make POWER/INSOLE/UNIVERSAL (Transformer oil shall be supplied in sealed container and empty barrel of transformer oil will be deposited by contractor in E/M store yard)
M&L for painting the transformer of any capacity by spray painting with applying two coats of synthetic enamel paint including prepartion of surface by scrapping old paint and writing SM No, MES No, and capacity of transformer in black paint on transformer all as specified and directed by Engineer-in-Charge and writing SM No, MES No, and capacity of transformer etc complete.
M&L for painting the panel Boards,Transformer fencing,Gates,Transformer Name plate boards by spray painting with applying two coats of synthetic enamel paint including prepartion of surface by scrapping old paint and writing SM No, MES No, and capacity of transformer on boards with white paint all as specified and directed by Engineer-in-Charge
M&L for repair to transformer pole mounted/plinth mounted of any capacity to stop the leakage of transformer by lifiting core assembley with the help of chain pully block/crane, removing transformer oil, replacing cork sheet gasket 5mm thick, reassembling, the transformer completely refilling transformer oil, connecting HT/LT connection,and required for replacement of unserviceable nuts/bolts/washer all as directed by Engineer-in-charge (Note : Spares required shall be measured and paid separately )
Material and labour for removing old silica gel, cleaning breather and filling new silica gel complete all as directed.
M&L for replacement of breather assembley with silica gel.
Supply only HT porecelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for following cap transformer :-
(a) 50 KVA to 100 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
Supply & fix in replacement of tap changer switch 11 KV complete with rod and gasket for following cap transformer :-
(a) 150 KVA to 250 KVA capacity
(b) 315 KVA to 400 KVA capacity
S & F in replacement of HV rod brass, 12mm dia with brass nut 2 Nos and rubber bush 300mm long all as directed by Engineer-in-Charge.
S & F in replacement of LV rod brass 15mm/20mm dia, 300mm long with rubber bushing and brass nuts 2 Nos all as directed by Engineer-in-Charge.
M&L for disconnection of defective transformer and shifting of trolly mounted transformer of 315 KVA capacity at required site and connecting to HT 11000 volt in coming from existing two pole structure and LT cable to LT panel and transporting the defective transformer to AGE E/M store yard complete as directed by Engineer-in-Charge.
M&L for disconnecting of defective transformer (indoor/outdoor type ) 11 KV/433 volts copper/ wound from power mains and dismantling the same from 2/4 pole structure/ platform mounted and transporting the same to authorised workshop and opening the transformer cover, draining out of tranformer oil and keep safely for reuse after filtration, assembling, removing of the burnt parts i.e tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all parts incluiding taking out HT/LT leg coil core tank and cooling tubes, painting the inner side tank by zinc chromate paint and preparing the same for re-assembling after carrying out required repair and installation on existing 2/4 pole structure/ platform with neccessary fixing arrangment including connecting up electrically, commissioning and testing all as directed by Engineer-in-Charge and specified in particular specification of the following capacity :- Note : (i) Rate quoted shall be inclusive of taking out and reinstalling after repair of transformer with the help of crane, including transportation to workshop and back incluiding handling. (ii) U/S wornout items required replacement shall be measured and paid separately under respective item of BoQ.
(a) 63-100 KVA transformer.
(b) 100-250 KVA transformer.
(c) 250-400 KVA transformer.
Supply Only new HV coil for item No 65.
(a) DPC Copper
(b) DPC Aluminium
Supply only of LV Coil for item No 65.
(a) Copper
(b) DPC Aluminium
M&L for replacement of drain valve 50 mm dia
M & L in replacement of Earthing complete chemical type with copper earth plate electrode 900 mm x 600mm x 5mm thick burried directly in ground (earth pit not less than 3mtr deep below ground level) with top edge of the plate not less than 2.25 mtr below normal ground level connected to and including copper strip earth lead 32mm x6 mm size by means of copper brazing strip and layers of salt, charcoal & magnesium sulphate including funnel with wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, including testing of earthing all as specified and directed by E-in-Charge.
NOTES: (a) Copper strip beyond 7.5m shall be measured and paid separately.(b) Charcoal (small pieces)-250Kg, Salt (Crystal) 250 Kg, Magnesium suplhate (crystal) -100 Kg.(c) Copper strip shall be brazed with copper plate electrode.(d) Alternate layers of charcoal and salts should be laid in the earth pit on the top of copper plate at least 5 layers should be laid.(e) After laying the 5 alternate layers of charcoal and slats a two inch layer of magnesium sulphate to be laid.(f) The chemical salt and magnesium sulphate should not be mixed, but are to be laid in layers only.(g) Copper strip is to be extended inside the equipment and power room it should routed in the side wall of the underground ducts fixed with creamics / porcelain spacers.(h)Contractor shall pour sufficient water in earth pit before and after doing earthing.(j) 25mm dia GI pipe suitable length to reach just about copper plate fitted with funnel meshed along with cap and running water tap to be provided for keeping the soil wet.(k) Soft soil (black cotton soil) shall be used in case of rocky terrain.(l) Brass nuts & bolts with proper washer to be used for copper strip jointing and necessary brazing shall be done as directed (m) The test point for each pit shall be made as directed & the cost is of the same to be include in the quoted rate.
S & F fuse wire 10 to 300 Amps copper incl making a good connection complete all as specified and directed by Engr in Charge.
Material & Labour Battery Acid.
Material & Labour for Distilled Water.
M & L for calibration of following relays of incoming and outgoing 11 KV VCBs with proper electronic instrument including testing and checking control cables.
(a) Over current and earth fault relay.
(b) Master trip relay.
S&F in replacement digital volt meter suitable for panel board mounting, 11 KV Make : L&T / Conzerv DM 3251.
S&F in replacement digital Ammeter suitable for panel board mounting, 11 KV Make : L&T / Conzerv DM 3252.
S & F in replacement MCCB 400 Amp 4 pole 36 KA complete all as specified and directed,Make - Standard/Havells/L&T
S & F in replacement MCCB 250 Amp 4 pole 36 KA complete all as specified and directed,Make - Standard/Havells/L&T
S & F in replacement MCCB 160 Amp 4 pole 36 KAcomplete all as specified and directed,Make - Standard/Havells/L&T
Labour for Disconnecting,Repairing,servicing and overhauling of existing HT 11 KV VCBs of any make from housing and cleaning, rubbing and overhauling the mechanical parts and servicing of 11 KV indoor VCB, checking of quality of vaccum interrupter, insulation resistances, static contact resistance, testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV current transformer (Set of three) by PRIMARY INJECTION KIT, and testing and calibration of relay (set of two over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of VCB, C&R panel and CTs, PTs complete all as directed. Note-1:contractor should make his own arrangement of testing equipments and electric supply so required.A detailed test report should be submitted to Engineer-in-Charge. Note-2:-All spares required for replacement shall be measured and paid separetely under respective items here-in- under as supply only.
Supply only indicator lamp suitable for VCB all as specified and directed by engg-in-charge..
Supply only limit switch all as specified and directed by engg-in-charge.
Supply only Master Trip Relay 110 Volt DC all as specified and directed by engg-in-charge.
Supply only Trip Circuit Supervising Relay all as specified and directed by engg-in-charge.
M & L for rewiring of Protection & Metering CTs, relays, meters contactors etc complete as required at site and as directed by Engr-in-Charge.
Supply only complete Mechanism assembly all as specified and directed by Engineer-in-Charge.
Supply only PT fuse set 3.15 amp all as specified and directed by Engineer-in-Charge
Supply only PT male femle contact all as specified and directed by Engineer-in-Charge.
Supply only Trip/close coil expect Bhel/Semen’s /ABB all as specified and directed by Engineer-in-Charge
Supply only Close coil all as specified and directed by Engineer-in-Charge
Supply only Spring charging motor all as specified and directed by Engineer-in-Charge.
Supply only Closing spring assembly all as specified and directed by Engineer-in-Charge.
Supply only Tripping spring assembly all as specified and directed by Engineer-in-Charge
Supply only Auxiliary switch all as specified and directed by Engineer-in-Charge
Supply only Vacuum interrupter 11kv VCB all as specified and directed by Engineer-in-Charge
M&L for cleaning & painting with double coat with Epoxy paint for VCB panel all as specified and directed by Engineer-in-Charge
Supply only Breaker control switch all as specified and directed by Engineer-in-Charge
Supply only Spout insulator (Epoxy) all as specified and directed by Engineer-in-Charge.
Supply only Caeadle insulator boot of busbar exisiting size all as specified and directed by Engineer-in-Charge.
Supply only Spout contact all as specified and directed by Engineer-in-Charge.
Supply only Over Current/Earth fault/Short Circuit current relay all as specified and directed by Engineer-in-Charge
Supply only Space Heater all as specified and directed by Engineer-in-Charge
Supply only Re-condition of breaker all as specified and directed by Engineer-in-Charge
Supply only Panel Heater all as specified and directed by Engineer-in-Charge
Supply and provide rubber mat of size 2m x 1m x 8mm thick all as specified and directed by Engineer-in-Charge
S & F in replacement 11 KV indoor current transformer (CT) set of 3 of CT ratio 100-50/5+5Amp,Core:1 15 VA/Cl.0.5,Core 2:15 VA/CI.SP10,STC:26.3KA/1 Sec all as specified and directed by Engineer-in-Charge
S & F in replacement New PT(Voltage Transformer)for 11 KV indoor VCB,Drw out type,11 KV,11000/110 V,VA-5 Class 1, Rated frequency 50 Hz all as specified and directed by Engineer-in-Charge.Make:CGL Approved Vendor.
S & F in replacement 11 KV Busbar current carrying capacity 800 amps 50 KA including mounting Insulator/Bushing and all accessories all as specified and directed by Engineer-in-Charge
S & F in replacement of battery bank 30 volts output by using maintanance free batteries,industrial type,duly charged and tested for 30 volts constant output including M & L required for modification in existing charging set for auto tripping arrangement to avoid over charging and to maintain 30 volts output continiously for tripping mechanism etc complete all as specified and directed by engineer-in-charge..
S & F in replacement of Battery Charging Equipment 30 V DC/100 Ah battery,Suitable for Auto/Manual Mode,Boost and float mode,in manual mode Step for increasing voltage,MCB for outgoing connection and one MCB separate for battery set and current for dc charging up to 15 Amp all as direccted by Engr-in-Charge.
Supply & Fix in replacement of Incomming and out going Bushing/retrofit with existing VCB all as specified and directed by Engineer-in-Charge
Supply, install, testing and commissioning and testing factory made and tested (including CPRI type test certified) in replacement of LT feeder pillar box (KIOSK) out door type, floor mounted,compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement.
Incoming:(a) MCCB 400 amps, 4 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 650 Amp, 4 pole, mounted on insulators for incomming supply 01 No (c) Volt meter and Amp meter 415 volts, 50 Hz AC supply -01 set. (d) Neon indicating lamps (R, Y & B) -01` Set. Outgoing: (a) MCCB 250 amps, 4 pole, 25 KA, 415 volts grade with thermal magnetic - 02 No (b) MCCB 200 amps, 4 pole, 25 KA, 415 volts grade with thermal magnetic - 02 No (c) MCCB 160 amps, 4 pole, 25 KA, 415 volts grade with thermal magnetic - 02 No (d) MCCB 100 amps, 4 pole, 25 KA, 415 volts grade with thermal magnetic - 02 No (e) MCB TPN 63 amps, 10 KA ,230 volts - 01No.
BHAVIN INFRA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .