Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 CrAccepted-AOC | L1 | Accepted-AOC Quoted Lowest Rate |
| Sl No | Description | Qty | Unit | HERITAGE INFRASTRUCTURES L1 |
|---|---|---|---|---|
| 1.00Kumartoli ghat | ||||
| 1.00 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
(a) Depth of excavation not exceeding 1,500 mm | 164.07 | Cum | 119.27 ₹19,568.63 Lowest |
| 1.00 | Supplying and laying Polythene Sheet (150gm / sq.m.) over
damp proof course or below flooring or roof terracing or in
foundation or in foundation trenches. | 1.17 | Sqm | 24 ₹28.08 Lowest |
| 1.00 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
(a) With earth obtained from excavation of foundation | 80.84 | Cum | 77.54 ₹6,268.33 Lowest |
| 1.00 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes Pakur Variety | 118.75 | Cum | 7,400 ₹8,78,750 Lowest |
| 1.01 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture]
(b) M 25 Grade | 65.53 | Cum | 7,750 ₹5,07,857.5 Lowest |
| 1.01 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work | 205.68 | Sqm | 369 ₹75,895.92 Lowest |
| 1.01 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
(a) For works in foundation and upto roof of ground floor/upto 4 m
(i) Tor steel/Mild Steel
I. SAIL/ TATA/RINL | 4.46 | MT | 76,000 ₹3,38,960 Lowest |
| 1.01 | Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. | 13 | Each | 2,000 ₹26,000 Lowest |
| 1.01 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection
8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof. | 2.35 | MT | 80,000 ₹1,88,000 Lowest |
Tender Value
₹16.9 Cr
EMD Value
₹33.8 L
Closing Date
3 Feb 2026, 3:00 pmClosed
Project Director
Office of WBTIDC Ltd. C.S.T.C. Kasba Depot Compound Kolkata-700107
Construction Re-construction of areas within 500 m radius of the jetties mentioned in the tender document
2026_WBTID_985713_3
IN-WBTIDCL-511213_CW_RFB
Open Tender
Miscellaneous Works
Lump-sum
360 days
Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹33.8 L
Office of WBTIDC Ltd.
25 Sept 2026
10 Jan 2026
3 Feb 2026
10 Jan 2026
3 Feb 2026
23 Jan 2026
19 Jan 2026
Kumartoli ghat
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes Pakur Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey in colour
Colour Decorative
40 mm thick fine dressed stone flooring over 20 mm(avarage) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortor 1:2 (1 cement : 2 stone dust) with an admixure of pigment to match the shade of stone. Red sand Stone
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50 micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section top and bottom member in dry-glaze sandwitch system, (unit wt. of top and bottom members: 0.375 kg/m & 0.69 kg/m) of approved brand and profile, EPDM quality rubber gaskets, anti dust tape, end closer "C" channel and 75 mm long Self tapping screw being drilled through the centre leg of the bottom section with nuts placed at 300 mm apart without anyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia & 3 mm thick washer etc complete strictly as per manufacturers specification and direction of Engineer-in- Charge. (Payment to be made on area of finished work) . In Roof:- Natural/ Blue/Green/Bronze/Opal/Metallic grey colour
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. Sludge measured in stack will be reduced by 8%).
Spreading of sludge, dump manure,/farm yard manure/animal dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Allamanda cathartica of height 30-45 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of plant Canna dwarf of height 60-90 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Single frame Signage Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed a
Supplying fixing and placing of cast iron ornamental canopy sheded structure including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge.
Digital Bill board Supplying fixing and placing of Digital Bill board (1.8 x3 m) including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge. P6 Outdoor LED Screen Pole- 12 inch diameter pole of 4 meter with 6 mm thickness, base ; plate -24X24 (16 mm), Top two plate - 24X24 inch ( 12 mm), Structure framing- 2X2 inch and 1.5X1.5 inch with 14 gauge thickness, Foundation - 2X2X5 feet, Anchor bolt -25 mm thick (8 nos.) Module Specification 1.Pixel pitch 6mm - 1/8 Scan 2 Leds SMD2727/2525 - King Light 3 Module size 192*192mm 4 IC ICN/SM/DP/FM 5 Pixel Density 27,777 dots/m² 6 module pixels 32*32 pixel Screen Parameters 1 Screen size 2 Cabinet 1.2mm MS cabinets with industrial double coat powder coating 960mm x 960mm x 110mm, weight of unit - 35Kg 3 Module Matrix 5 x 5 4 cabinet pixels 160*160 5 Brightness ≥6500cd/ 6 Viewing Angle H: 140° ,V 140° 7 View distance >6m 8 Gray level 16 bit 9 Refresh rate ≥1920hz 10 Frequence 60Hz 11 Input AC220-240V 12 Power comsuption Max:650W/ Average:300W/ 13 MTBF--hours >10,000 hours 14 Life--hours ≥100,000 hours 15 IP rating IP67 front / IP57 Back 16 Operating Temperature from -40℃~60℃ 17 Storage Humidity 10℃~90℃RH 18 Control syetem HUIDU 19 Power supply CZCL/G-energy/Y
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying & installation, testing and commissioning of 2.8 M Height post top lantern of 35 watt LED including the light pole (2.8 m) make by Cast Iron with all accessories and including connection etc. and complete as per Electrical Engineer-inCharge and consultants.
Supplying & installation, testing and commissioning of TREE UPLIGHTER , IP66 LED spike light using COB LED as light source. Offered in Mono – Red, Green, Blue and Warm White Colour. (HAVELLS/CROMPTON/jaguar) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning of RECESSED LIGHT-18 watt LED (fixed on wall) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning WALL WASHER LIGHT-36 watt LED (fixed on wall) SITC of 36W 1000mm long Mono color Linear Wall Washer with Non-integral driver and completely made in India luminaire. Housing: Extruded aluminum powder coated in grey, IP66, IK07, Optics: high purity integrated polycarbonate lens. CRI min. 80 (Standard White Light) and shall have SDCM=5. CCT- 3000K, Lumens min. 1980 lumens, Beam angle shall be 11°,15°,30°,60° or Asymmetric optional. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on Each an every light fixtures. Dimension: 1000 X 35 X 39mm (±5mm) excluding bracket, Weight: 1.1Kg Similar to Above specifications or equivalent . and complete as per Electrical Engineer-in Charge and consultants.
Supply and laying of 16 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply and laying of 10 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply & fixing of 4.0 sq,mm, 2 core Aluminimum service wire including all acessories and connections.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp
Supplying HDPE (Materials grade PE-100) pipes conforming to IS 4984-1995 with latest revision & amendments if any with necessary HDPE specials (excluding cost of CIDF valves) including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder,road sub-grade and aits flank but excluding moorum laterite or sand stone / hard rock cutting with chisel required including cutting road flank/ brick pavement etc. without damaging the exisiting telephone/electrical cable line etc.(in case of damage of any type of cable line by the agency at the time of execution necessary damage charge as applicable by the respective authority will have to be brone by the agency at his own cost)upto the depth (av.) so as to maintain 1.10m.earth cushion from top of the pipe upto G.L. including loading unloading carrying lowering laying fitting fixing carefully pipes, valves and specials with the all types of jointing materials in trenches maintaining proper levels and alignment jointing the pipes and specials by butt welding/ adopting suitable method (But weld jointing with help of hydraulic tack and trimming machines, Hitter etc. for reaching at necessary melting point of HDPE pipe so that joint can be monolithic) so as to facilitate the maintenance of pipe line locally as per conventional method in future. (B) Pressure Rating : PN 10 (i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings valves a) 75mm(OD)
Champatala Ghat
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes a) Pakur Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In superstructure, ground floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
40 mm thick fine dressed stone flooring over 20 mm(avarage) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortor 1:2 (1 cement : 2 stone dust) with an admixure of pigment to match the shade of stone. Red sand Stone
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. Sludge measured in stack will be reduced by 8%).
Spreading of sludge, dump manure,/farm yard manure/animal dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
Providing and stacking of Allamanda cathartica of height 30-45 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Single frame Signage Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Supplying fixing and placing of cast iron ornamental canopy sheded structure including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying & installation, testing and commissioning of 2.8 M Height post top lantern of 35 watt LED including the light pole (2.8 m) make by Cast Iron with all accessories and including connection etc. and complete as per Electrical Engineer-inCharge and consultants.
Supplying & installation, testing and commissioning of TREE UPLIGHTER , IP66 LED spike light using COB LED as light source. Offered in Mono – Red, Green, Blue and Warm White Colour. (HAVELLS/CROMPTON/jaguar) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning of RECESSED LIGHT-18 watt LED (fixed on wall) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning WALL WASHER LIGHT-36 watt LED (fixed on wall) SITC of 36W 1000mm long Mono color Linear Wall Washer with Non-integral driver and completely made in India luminaire. Housing: Extruded aluminum powder coated in grey, IP66, IK07, Optics: high purity integrated polycarbonate lens. CRI min. 80 (Standard White Light) and shall have SDCM=5. CCT- 3000K, Lumens min. 1980 lumens, Beam angle shall be 11°,15°,30°,60° or Asymmetric optional. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on Each an every light fixtures. Dimension: 1000 X 35 X 39mm (±5mm) excluding bracket, Weight: 1.1Kg Similar to Above specifications or equivalent . and complete as per Electrical Engineer-in Charge and consultants.
Supply and laying of 16 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply and laying of 10 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply & fixing of 4.0 sq,mm, 2 core Aluminimum service wire including all acessories and connections.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp
Supplying HDPE (Materials grade PE-100) pipes conforming to IS 4984-1995 with latest revision & amendments if any with necessary HDPE specials (excluding cost of CIDF valves) including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder,road sub-grade and aits flank but excluding moorum laterite or sand stone / hard rock cutting with chisel required including cutting road flank/ brick pavement etc. without damaging the exisiting telephone/electrical cable line etc.(in case of damage of any type of cable line by the agency at the time of execution necessary damage charge as applicable by the respective authority will have to be brone by the agency at his own cost)upto the depth (av.) so as to maintain 1.10m.earth cushion from top of the pipe upto G.L. including loading unloading carrying lowering laying fitting fixing carefully pipes, valves and specials with the all types of jointing materials in trenches maintaining proper levels and alignment jointing the pipes and specials by butt welding/ adopting suitable method (But weld jointing with help of hydraulic tack and trimming machines, Hitter etc. for reaching at necessary melting point of HDPE pipe so that joint can be monolithic) so as to facilitate the maintenance of pipe line locally as per conventional method in future. (B) Pressure Rating : PN 10 (i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings valves a) 75mm(OD)
Sovabazar Ghat
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (ii)Grill weighing above 16 Kg./sq.mtr and above
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In superstructure, ground floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey in colour Grey In colour
Colour Decorative
40 mm thick fine dressed stone flooring over 20 mm(avarage) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortor 1:2 (1 cement : 2 stone dust) with an admixure of pigment to match the shade of stone. Red sand Stone
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. Sludge measured in stack will be reduced by 8%).
Spreading of sludge, dump manure,/farm yard manure/animal dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
Providing and stacking of Allamanda cathartica of height 30-45 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of plant Canna dwarf of height 60-90 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Single frame Signage Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Digital Bill board Supplying fixing and placing of Digital Bill board (1.8 x3 m) including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge. P6 Outdoor LED Screen Pole- 12 inch diameter pole of 4 meter with 6 mm thickness, base ; plate -24X24 (16 mm), Top two plate - 24X24 inch ( 12 mm), Structure framing- 2X2 inch and 1.5X1.5 inch with 14 gauge thickness, Foundation - 2X2X5 feet, Anchor bolt -25 mm thick (8 nos.) Module Specification 1.Pixel pitch 6mm - 1/8 Scan 2 Leds SMD2727/2525 - King Light 3 Module size 192*192mm 4 IC ICN/SM/DP/FM 5 Pixel Density 27,777 dots/m² 6 module pixels 32*32 pixel Screen Parameters 1 Screen size 2 Cabinet 1.2mm MS cabinets with industrial double coat powder coating 960mm x 960mm x 110mm, weight of unit - 35Kg 3 Module Matrix 5 x 5 4 cabinet pixels 160*160 5 Brightness ≥6500cd/ 6 Viewing Angle H: 140° ,V 140° 7 View distance >6m 8 Gray level 16 bit 9 Refresh rate ≥1920hz 10 Frequence 60Hz 11 Input AC220-240V 12 Power comsuption Max:650W/ Average:300W/ 13 MTBF--hours >10,000 hours 14 Life--hours ≥100,000 hours 15 IP rating IP67 front / IP57 Back 16 Operating Temperature from -40℃~60℃ 17 Storage Humidity 10℃~90℃RH 18 Control syetem HUIDU 19 Power supply CZCL/G-energy/Y
Supplying fixing and placing of cast iron ornamental canopy sheded structure including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying & installation, testing and commissioning of 2.8 M Height post top lantern of 35 watt LED including the light pole (2.8 m) make by Cast Iron with all accessories and including connection etc. and complete as per Electrical Engineer-inCharge and consultants.
Supplying & installation, testing and commissioning of TREE UPLIGHTER , IP66 LED spike light using COB LED as light source. Offered in Mono – Red, Green, Blue and Warm White Colour. (HAVELLS/CROMPTON/jaguar) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning of RECESSED LIGHT-18 watt LED (fixed on wall) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning WALL WASHER LIGHT-36 watt LED (fixed on wall) SITC of 36W 1000mm long Mono color Linear Wall Washer with Non-integral driver and completely made in India luminaire. Housing: Extruded aluminum powder coated in grey, IP66, IK07, Optics: high purity integrated polycarbonate lens. CRI min. 80 (Standard White Light) and shall have SDCM=5. CCT- 3000K, Lumens min. 1980 lumens, Beam angle shall be 11°,15°,30°,60° or Asymmetric optional. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on Each an every light fixtures. Dimension: 1000 X 35 X 39mm (±5mm) excluding bracket, Weight: 1.1Kg Similar to Above specifications or equivalent . and complete as per Electrical Engineer-in Charge and consultants.
Supply and laying of 16 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply and laying of 10 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply & fixing of 4.0 sq,mm, 2 core Aluminimum service wire including all acessories and connections.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp
Supplying HDPE (Materials grade PE-100) pipes conforming to IS 4984-1995 with latest revision & amendments if any with necessary HDPE specials (excluding cost of CIDF valves) including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder,road sub-grade and aits flank but excluding moorum laterite or sand stone / hard rock cutting with chisel required including cutting road flank/ brick pavement etc. without damaging the exisiting telephone/electrical cable line etc.(in case of damage of any type of cable line by the agency at the time of execution necessary damage charge as applicable by the respective authority will have to be brone by the agency at his own cost)upto the depth (av.) so as to maintain 1.10m.earth cushion from top of the pipe upto G.L. including loading unloading carrying lowering laying fitting fixing carefully pipes, valves and specials with the all types of jointing materials in trenches maintaining proper levels and alignment jointing the pipes and specials by butt welding/ adopting suitable method (But weld jointing with help of hydraulic tack and trimming machines, Hitter etc. for reaching at necessary melting point of HDPE pipe so that joint can be monolithic) so as to facilitate the maintenance of pipe line locally as per conventional method in future. (B) Pressure Rating : PN 10 (i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings valves a) 75mm(OD)
Beniatola Ghat
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In superstructure, ground floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
40 mm thick fine dressed stone flooring over 20 mm(avarage) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortor 1:2 (1 cement : 2 stone dust) with an admixure of pigment to match the shade of stone. Red sand Stone
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. Sludge measured in stack will be reduced by 8%).
Spreading of sludge, dump manure,/farm yard manure/animal dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
Providing and stacking of Allamanda cathartica of height 30-45 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Single frame Signage Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Supplying fixing and placing of cast iron ornamental canopy sheded structure including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying & installation, testing and commissioning of 2.8 M Height post top lantern of 35 watt LED including the light pole (2.8 m) make by Cast Iron with all accessories and including connection etc. and complete as per Electrical Engineer-inCharge and consultants.
Supplying & installation, testing and commissioning of TREE UPLIGHTER , IP66 LED spike light using COB LED as light source. Offered in Mono – Red, Green, Blue and Warm White Colour. (HAVELLS/CROMPTON/jaguar) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning of RECESSED LIGHT-18 watt LED (fixed on wall) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning WALL WASHER LIGHT-36 watt LED (fixed on wall) SITC of 36W 1000mm long Mono color Linear Wall Washer with Non-integral driver and completely made in India luminaire. Housing: Extruded aluminum powder coated in grey, IP66, IK07, Optics: high purity integrated polycarbonate lens. CRI min. 80 (Standard White Light) and shall have SDCM=5. CCT- 3000K, Lumens min. 1980 lumens, Beam angle shall be 11°,15°,30°,60° or Asymmetric optional. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on Each an every light fixtures. Dimension: 1000 X 35 X 39mm (±5mm) excluding bracket, Weight: 1.1Kg Similar to Above specifications or equivalent . and complete as per Electrical Engineer-in Charge and consultants.
Supply and laying of 16 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply and laying of 10 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply & fixing of 4.0 sq,mm, 2 core Aluminimum service wire including all acessories and connections.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp
Supplying HDPE (Materials grade PE-100) pipes conforming to IS 4984-1995 with latest revision & amendments if any with necessary HDPE specials (excluding cost of CIDF valves) including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder,road sub-grade and aits flank but excluding moorum laterite or sand stone / hard rock cutting with chisel required including cutting road flank/ brick pavement etc. without damaging the exisiting telephone/electrical cable line etc.(in case of damage of any type of cable line by the agency at the time of execution necessary damage charge as applicable by the respective authority will have to be brone by the agency at his own cost)upto the depth (av.) so as to maintain 1.10m.earth cushion from top of the pipe upto G.L. including loading unloading carrying lowering laying fitting fixing carefully pipes, valves and specials with the all types of jointing materials in trenches maintaining proper levels and alignment jointing the pipes and specials by butt welding/ adopting suitable method (But weld jointing with help of hydraulic tack and trimming machines, Hitter etc. for reaching at necessary melting point of HDPE pipe so that joint can be monolithic) so as to facilitate the maintenance of pipe line locally as per conventional method in future. (B) Pressure Rating : PN 10 (i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings valves a) 75mm(OD)
Nimtala Ghat
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In superstructure, ground floor
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey in colour Grey In colour
Colour Decorative
40 mm thick fine dressed stone flooring over 20 mm(avarage) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortor 1:2 (1 cement : 2 stone dust) with an admixure of pigment to match the shade of stone. Red sand Stone
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50 micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section top and bottom member in dry-glaze sandwitch system, (unit wt. of top and bottom members: 0.375 kg/m & 0.69 kg/m) of approved brand and profile, EPDM quality rubber gaskets, anti dust tape, end closer "C" channel and 75 mm long Self tapping screw being drilled through the centre leg of the bottom section with nuts placed at 300 mm apart without anyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia & 3 mm thick washer etc complete strictly as per manufacturers specification and direction of Engineer-in- Charge. (Payment to be made on area of finished work) . In Roof:- Natural/ Blue/Green/Bronze/Opal/Metallic grey colour
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. Sludge measured in stack will be reduced by 8%).
Spreading of sludge, dump manure,/farm yard manure/animal dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Allamanda cathartica of height 30-45 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of plant Canna dwarf of height 60-90 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Single frame Signage Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Digital Bill board Supplying fixing and placing of Digital Bill board (1.8 x3 m) including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge. P6 Outdoor LED Screen Pole- 12 inch diameter pole of 4 meter with 6 mm thickness, base ; plate -24X24 (16 mm), Top two plate - 24X24 inch ( 12 mm), Structure framing- 2X2 inch and 1.5X1.5 inch with 14 gauge thickness, Foundation - 2X2X5 feet, Anchor bolt -25 mm thick (8 nos.) Module Specification 1.Pixel pitch 6mm - 1/8 Scan 2 Leds SMD2727/2525 - King Light 3 Module size 192*192mm 4 IC ICN/SM/DP/FM 5 Pixel Density 27,777 dots/m² 6 module pixels 32*32 pixel Screen Parameters 1 Screen size 2 Cabinet 1.2mm MS cabinets with industrial double coat powder coating 960mm x 960mm x 110mm, weight of unit - 35Kg 3 Module Matrix 5 x 5 4 cabinet pixels 160*160 5 Brightness ≥6500cd/ 6 Viewing Angle H: 140° ,V 140° 7 View distance >6m 8 Gray level 16 bit 9 Refresh rate ≥1920hz 10 Frequence 60Hz 11 Input AC220-240V 12 Power comsuption Max:650W/ Average:300W/ 13 MTBF--hours >10,000 hours 14 Life--hours ≥100,000 hours 15 IP rating IP67 front / IP57 Back 16 Operating Temperature from -40℃~60℃ 17 Storage Humidity 10℃~90℃RH 18 Control syetem HUIDU 19 Power supply CZCL/G-energy/Y
Supplying fixing and placing of cast iron ornamental canopy sheded structure including the civil foundation works complete as per drawing , specification and direction of Engineer-in-charge. C1 : 2CI
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying & installation, testing and commissioning of 2.8 M Height post top lantern of 35 watt LED including the light pole (2.8 m) make by Cast Iron with all accessories and including connection etc. and complete as per Electrical Engineer-inCharge and consultants.
Supplying & installation, testing and commissioning of TREE UPLIGHTER , IP66 LED spike light using COB LED as light source. Offered in Mono – Red, Green, Blue and Warm White Colour. (HAVELLS/CROMPTON/jaguar) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning of RECESSED LIGHT-18 watt LED (fixed on wall) with all accessories and including connection etc. and complete as per Electrical Engineer-in Charge and consultants.
Supplying & installation, testing and commissioning WALL WASHER LIGHT-36 watt LED (fixed on wall) SITC of 36W 1000mm long Mono color Linear Wall Washer with Non-integral driver and completely made in India luminaire. Housing: Extruded aluminum powder coated in grey, IP66, IK07, Optics: high purity integrated polycarbonate lens. CRI min. 80 (Standard White Light) and shall have SDCM=5. CCT- 3000K, Lumens min. 1980 lumens, Beam angle shall be 11°,15°,30°,60° or Asymmetric optional. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on Each an every light fixtures. Dimension: 1000 X 35 X 39mm (±5mm) excluding bracket, Weight: 1.1Kg Similar to Above specifications or equivalent . and complete as per Electrical Engineer-in Charge and consultants.
Supply and laying of 16 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply and laying of 10 Sqmm 2 core PVC Al. Arm Cable of 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
Supply & fixing of 4.0 sq,mm, 2 core Aluminimum service wire including all acessories and connections.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp
Supplying HDPE (Materials grade PE-100) pipes conforming to IS 4984-1995 with latest revision & amendments if any with necessary HDPE specials (excluding cost of CIDF valves) including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder,road sub-grade and aits flank but excluding moorum laterite or sand stone / hard rock cutting with chisel required including cutting road flank/ brick pavement etc. without damaging the exisiting telephone/electrical cable line etc.(in case of damage of any type of cable line by the agency at the time of execution necessary damage charge as applicable by the respective authority will have to be brone by the agency at his own cost)upto the depth (av.) so as to maintain 1.10m.earth cushion from top of the pipe upto G.L. including loading unloading carrying lowering laying fitting fixing carefully pipes, valves and specials with the all types of jointing materials in trenches maintaining proper levels and alignment jointing the pipes and specials by butt welding/ adopting suitable method (But weld jointing with help of hydraulic tack and trimming machines, Hitter etc. for reaching at necessary melting point of HDPE pipe so that joint can be monolithic) so as to facilitate the maintenance of pipe line locally as per conventional method in future. (B) Pressure Rating : PN 10 (i) Laying of pipe line including cost of pipe only excluding cost of specials/fittings valves a) 75mm(OD)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mt
Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised "C" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc(V) 100 mm. x 100 mm. x 6 g.
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey
Colour Decorative
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart
Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge
Manufacture and Supply of 2 seatter portable toilet with cabin size 4x6x7ft. Made of FRP sandwich pannels, FRP Partition wall diveded the Toiles in two cabin Each cabin size is 2.6x2.4x7ft., FRP Roof & 02 Nos. FRP doors of size 6x2ft., including BIO-DIGESTER WASTE TANK (1nos): 5000 ltr. Material of construction FRP thickness 5mm avg., 2 water closet squatting pan (Indian type W.C. pan ), PVC Water Tank, 1 Wash basin, Towel hanger, Cloth hook, shop disk, mirror .Soap Dispenser, all UPVC plumbing fitting internal & External connections, all Elictricity fitting with 2Nos & 7wattt led bulb & outside connections etc. all complete according the site-in charge and according to the approved design and Brand.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Single Frame Pole Sign MPO Octagonal Single sided Pole With 100 mm Frames Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey
Colour Decorative
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Single Frame Pole Sign MPO Octagonal Single sided Pole With 100 mm Frames Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey
Colour Decorative
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Single Frame Pole Sign MPO Octagonal Single sided Pole With 100 mm Frames Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey
Colour Decorative
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Single Frame Pole Sign MPO Octagonal Single sided Pole With 100 mm Frames Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-ChargeGrey
Colour Decorative
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for Each additional floor or 4m. beyond the initial 8 m. or part thereof.
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Brick work with 1st class modular bricks (a) With cement mortar (1:4) In foundation and plinth
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Grey
Colour Decorative
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface : (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Providing and stacking of Plumeria alba of height 180-210 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge Colour Decorative
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Single Frame Pole Sign MPO Octagonal Single sided Pole With 100 mm Frames Providing and fixing in position Illuminated Pole mounted-Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Consisting of main pole 80 mm Octagonal shaped (2 nos) screw fitted with M.S structure vertically & horizontally, Coverlist profile inserted in octagonal shaped profile to hide screw fitting arrangement completely. Plastic moulded endcap (black coloured) on top side to cover octagonal shaped profile, to with 100 mm depth aluminium frame with 80 mm radius round corners as per design requirements for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size -As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). ii) Grading – II
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-ChargeColour Decorative
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete as per Clause 803 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
Manufacture and Supply of 2 seatter portable toilet with cabin size 4x6x7ft. Made of FRP sandwich pannels, FRP Partition wall diveded the Toiles in two cabin Each cabin size is 2.6x2.4x7ft., FRP Roof & 02 Nos. FRP doors of size 6x2ft., including BIO-DIGESTER WASTE TANK (1nos): 5000 ltr. Material of construction FRP thickness 5mm avg., 2 water closet squatting pan (Indian type W.C. pan ), PVC Water Tank, 1 Wash basin, Towel hanger, Cloth hook, shop disk, mirror .Soap Dispenser, all UPVC plumbing fitting internal & External connections, all Elictricity fitting with 2Nos & 7wattt led bulb & outside connections etc. all complete according the site-in charge and according to the approved design and Brand.
Finger Post Multiple Frames Sign MPO Octagonal Single sided Pole With 50 mm Frames Providing and fixing in position Illuminated Pole mounted Speed limit -Informational signage consisting of the following: 1. Signage face made out of ‐ 3mm thick Aluminum sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics as per requirement of respective vinyl and shade. 2. Signage structure ‐ MS square post shaped 75 x 35 x 5 mm (channel made up of 35 x 35 X 3; L angles) and mounting square sections, powder coated as per . Mounting square section span and the wind loads. 3. Sign frame - Cosign make modular aluminium profile Module plus outdoor system -Main pole of 150 x 100 mm x 8 mm (thickness) .Alumnium extrusion (can be engraved if required on surfaces) attached to with 50 mm depth aluminium frame with 80 mm radius round corners as per design requirements angled cut to match given design intent partially for media signage mounting , with media accomodation depth of 6 mm , frame screw fitted at multiple position along vertical and horizontal side facing the octagonal pole. 4. Media - ACP /Acrylic router cut - vinyl warraped / pasted with thickness upto 5 mm can be pasted (with help of dual lock or foam based 3M make double sided tape) on 50 mm depth profile (on both side) . 5. illumination - LUCOLED make edge lit LED modules with IP67 rating with 5 years warranty to be installed as per graphical requirement. including post, RCC foundations, electrical connections (as required), cutting and opening the floor finish (as required) at location, and making good to match the original finish after fixing and installation of signage with all accessories such as thimbles, end connectors, nut‐inserts, screws, rivets, bolts, washers, nuts, etc. all complete with due considerations to harsh outdoor conditions as per approved design/ drawings and instructions of the engineer-in-charge Size - As per drawing.
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) 60 cm circular
i) 90 cm equilateral triangle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specifications Clause 202 for Rural Roads of MORD.a) Bituminous Courses
b) Granular Courses
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.(a) upto 150 mm. thick
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Solid waste Management
Pair of 100L Metal Bin with Stand
Pair of 100L Metal Bin with Stand
Pair of 100L capacity HDPE bin placed within frame
Pair of 100L capacity HDPE bin placed within frame
Platfrom for Pair of 100L capacity HDPE bin
Pair of 240L capacity HDPE bin
Platform with Shed for Pair of 240L capacity HDPE bin
Pair of 240L capacity HDPE bin
Entrance Gate 1
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codesa) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work PCC
Column
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade Raft
Column
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Supplying and installation of Cast Iron and MS structure entrance Gate (Pilllar ) according to the approved drawing including Calligraphy work and other necessery items directed by the engineer in- charge.
Entrance Gate 2
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes a) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work PCC
Column
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix formula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade Raft
Column
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor b) Area of Each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary i) With 1:4 cement mortar c) 10 mm thick plaster
Supplying and installation of Cast Iron and MS structure entrance Gate (Pilllar ) according to the approved drawing including Calligraphy work and other necessery items directed by the engineer in- charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 8.40 MB
BOQ_2406611.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .