Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹66,059.68Admitted-Finance | -31.90% | ₹66,059.68 | L1 | Admitted-Finance |
| 2 | L2₹70,715.87Admitted-Finance | -27.10% | ₹70,715.87 | L2 | Admitted-Finance |
| 3 | L3₹80,008.84Admitted-Finance | -17.52% | ₹80,008.84 | L3 | Admitted-Finance |
Tender Value
₹97,000
EMD Value
₹1,940
Closing Date
20 Feb 2026, 6:00 pmClosed
XEN OFFICE REW JAMMU
XEN OFFICE REW JAMMU
Repair of Passenger shed at pargwal lower Pyt Pargwal lower Block Pargwal AC Akhnoor under CDF for the year of 2025 26
2026_RDPR_303184_1
e-NIT No. 829 REWJ of 2025-26 dated 14-02-2026
Open Tender
Civil Works
XEN OFFICE REW JAMMU
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
MH0515
₹1,940
Yes
21 Feb 2026
14 Feb 2026
21 Feb 2026
14 Feb 2026
20 Feb 2026
14 Feb 2026
Labour engaged for site clearance
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:15.2.1 1:3:6 or richer mix (i/c equivalent design mix)
Reinforced cement concrete in beams ,suspended floors.roofs having slopes upto 15 degree landings,balconies,shelves,chajjas,lintels,bands, plain windows sills,stair cases and spiral stair cases upto 5 level including curing but excluding the cost of centering, shuttering and reinforcement with 1:1.5:3 (1 Cement:1.5 Coarse sand:3 Graded stone aggregate 20mm nominal size)
Steel Reinforcement for RCC Work including straightening,cutting,bending, placing in position and binding all complete above plinth level . Cold twisted bars fe500
Brick work in bricks of class designation 7.5 in superstructure above plinth level upto floor five level and curing complete in: 6.37.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :6.15.2 Cement mortar 1:4 ( 1 cement : 4 coarse sand)
12mm thick cement plaster of mix 1:6
15mm thick cement plaster of mix 1:6
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. 23.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm
Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Finishing walls with water proofing cement paint of required shade: 13.117.1 Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete.
Lettering with black Japan paint of approved brand and manufacture.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Supplying and fixing of ceiling fan 1200mm sweep.
Carriage of sand av. lead of 5 Km by MT
Carriage of aggregate below 40 mm av lead of 25 KM by MT
carriage of bricks @25 KM by MT
Providing & fixing sign board
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_983948.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid