| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAdmitted-Finance | ₹16.4 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technical Bid Rejected |
| Sl No | Description | Qty | Unit | Suraj Borse L1 |
|---|---|---|---|---|
| 1.00Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | ||||
| 1.10 | Group A | 246 | Point | 1,000 ₹2,46,000 Lowest |
| 1.20 | Group B | 24 | Point | 1,140 ₹27,360 Lowest |
| 2.00Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | ||||
| 2.10 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 650 | Metre | 235 ₹1,52,750 Lowest |
| 2.20 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 450 | Metre | 400 ₹1,80,000 Lowest |
| 2.30 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 225 | Metre | 625 ₹1,40,625 Lowest |
| 3.00Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. | ||||
| 3.10 | 3 Module (100mmX75mm) | 191 | Each | 300 ₹57,300 Lowest |
| 3.20 | 8 Module (125mmX125mm) | 19 | Each | 500 ₹9,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹24,898
Closing Date
4 Jul 2025, 11:00 amClosed
Executive Engineer E BSNL ED Mumbai
The Executive Engineer E BSNL Electrical Division Gr Floor A Wing BSNL Admin Bldg Juhu Tara Road Santacruz West Mumbai 400054
Providing EI and Fans of Staff Quarters at Porvorim and Bambolim Goa.
2025_BSNL_238994_1
1300/CEEM/2025-26/NIT/13
Open Tender
Electrical Works
Item Rate
30 days
Porvorim and Bambolim Goa
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer (F and A) BSNL, Mumbai
₹24,898
Yes
23 Aug 2025
20 Jun 2025
5 Jul 2025
20 Jun 2025
4 Jul 2025
20 Jun 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group A
Group B
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
3 Module (100mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2 + 8 way, Double door
2 + 12 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 5A to 32A 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing earth bus of 50 mm X 5 mm GI strip 0.4 metre long with 2 nos. epoxy insulator mounting on surface for connections etc. as required.
Supplying and fixing of marine ply wood of 12mm thick (Nominal) ISI mark in Meter cabin including removing the existing exhausted ply wood etc. complete as required. (Note: This item is to be executed in meter cabin of Staff Qtr building)
SITC of 20 Watts aluminium batten LED tube fitting |Aluminium heat sink | Cool Day Light (6500K) with 2000 lumen, on wall/ceiling complete as reqd.(Philips/ Panasonic/ CG or SS Make)
Supply and fixing of 50 watts LED Compound light fitting with 20 mm dia GI wall bracket etc. complete as rqed. (M/s. Havells or Philips/ Panasonic/ CG or SS Make)
Supplying of following size PVC insulated and PVC sheathed / XLPE armoured Aluminium conductor power cable of 1.1 KV grade as required.
4 x 25 sq.mm
2 x 6 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 25 sq. mm (28mm)
2 X 6 sq. mm (19mm)
Dismantling of various old exisitng electrical fans, light fittings, switchgears, DB, wiring, accessories, etc. as directed and preparing inventory, stacking, storing in store room as directed by Engineer in charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .