| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹10.9 L+₹88,245 (8.83%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹11.0 L+₹96,703 (9.67%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹11.3 L+₹1.3 L (13.2%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹11.4 L+₹1.4 L (14.5%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
22 Jul 2022, 6:00 pmClosed
ABHISHEK KUMAR YADAV
AGE I AF SINGARSI
Repair Maint of feeder pillar Box including connected works at AF Stn Singarsi under AGE I AF Singarsi
2022_MES_533268_1
C/8554/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹19,000
Yes
25 Aug 2022
24 Jun 2022
25 Jul 2022
24 Jun 2022
22 Jul 2022
27 Jun 2022
Amount
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose or any other type of soil for taking up or laying of cable complete all as specified and directed by Engr-in-Charge.
All as per item No 1 above but hard surfaces such as in road cutting/ hard standing etc including making good disturbed surfaces to match with original complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point complete all as specified and directed by Engr-in-Charge.
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering complete all as specified and directed by Engr-in-Charge. Note:- Punned quntity will be measured paid at this item.
Supply and laying in replacement of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable including taking up of old Unserviceable bricks complete all as specified and directed by Engr-in-Charge.
Supply and Fixing in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor (multistranded), 1100 volts grade connected with suitable cable gland and aluminium lugs of any size laid in trenches or passing through pipes including testing after laying, including taking up old UNSV cable complete of 16 Sqmm, 4 Core size all as specified and directed by Engineer-in-Charge. Make : Polycab/Universal/Plaza/Gloster/Havells/Nicco/CCI.
All as per item No 7 but 25 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 7 but 70 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 7 but 300 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and Fixing in replacement of following GI pipe light grade (ISI Marked) for cable protection along wall/pole/floor/road crossing etc complete including sealing of pipe ends with approved sealing compound including taking up old UNSV GI pipe of 50mm dia complete all as specified and directed by Engineer-in-Charge. (Make – TATA/Prakash/Jindal/Swastik)
All as per item No 11 but 80 mm dia complete all as specified and directed by Engr-in-Charge.
M&L Danger notice plate of 1.6mm thick mild steel sheet, of size 250mm x 200mm for 11 KV, vitreous enamelled white, with letter, figures and convetional skull and bones in signal red colour and fixed in front side with suitable screws / nuts, bolts & washers complete all as specified and directed by Engr-in-Charge.
All as per item No 13 here in before but of size 200mm x 150mm for LT complete all as specified and directed by Engr-in-Charge.
S&F in repair MCCB 125 A, 4 pole, 415 Volts 36 KA breaking Capacity ,AAN frame fixed onExisting pannel in power house/feeder pannel and connecting up all as specified and as directed& in the process of fixing of MCCB minor drilling, clamping ,screw ,nut bolt included in quoted rate complete all as specified and directed by Engr-in-Charge. Make-: L&T/ Havells / Hager/Legrand
All as per Item No 15 but for 100Amp complete all as specified and directed by Engr-in-Charge.
All as per item No 15 but for 200Amp complete all as specified and directed by Engr-in-Charge.
M/L in replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade , charcoal dust and salt etc and connected to earthing test point including taking up of old UNSV earthing complete all as specified and directed by Engr-in-Charge.
M/S AMARNATH AGARWALLA
M/S Subhadip Enterprise
DANATION CONSTRUCTIONS
LALAN SHARMA
M/S New Builders Corporation
M/S ASHA ENTERPRISE
M/S KUMAR AVINASH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .