| 1 | L1₹22.5 LAccepted-AOC | ₹22.5 L Quoted ₹23.0 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹23.4 L+₹44,926 (1.96%)Rejected-Finance | ₹23.4 L+₹44,926 (1.96%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹23.6 L+₹59,542.31 (2.59%)Rejected-Finance | ₹23.6 L+₹59,542.31 (2.59%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹23.9 L+₹92,779 (4.04%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹23.9 L+₹92,779 (4.04%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹24.6 L+₹1.6 L (7.18%)Rejected-Finance | ₹24.6 L+₹1.6 L (7.18%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L4 | SHANTI MARKETING AND SERVICES L6 | Haasith constructions L7 | SANJEEV CONSTRUCTIONS L5 | MS ENTERPRISES L3 | DPS sales and services india L8 | Srinivash Engineers L1 | VS ENTERPRISES L2 | LEOENTERPRISES L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S & F panel and its connections and supply and install, testing and commissioning of Out door LT feeder panel factory made cubicle 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar 600 Amps of suitable size, Al strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following :- | 1 | Each | 2,25,000 ₹2,25,000 | 2,70,000 ₹2,70,000 | 1,95,541.55 ₹1,95,541.55 | 2,34,000 ₹2,34,000 | 1,83,993 ₹1,83,993 | 1,54,500 ₹1,54,500 | 1,80,000 ₹1,80,000 | 1,90,000 ₹1,90,000 | 1,35,000 ₹1,35,000 Lowest |
| 1.01(a) MCCB 4 Pole 400 Amps 36KA -01 No. Microprocessor release with adjustable overload setting (incomer) (b) MCCB 4 Pole 320 Amps 36KA -02 Nos. Microprocessor release with adjustable overload setting (Outgoing) (c) MCCB 4 Pole 200 Amps 25KA -01 No Microprocessor release with adjustable overload setting (Outgoing) (d) MCCB 4 Pole 160 Amps 25 KA - 01 No Microprocessor release with adjustable overload setting (Outgoing) (e) MCCB 4 Pole 100 Amps 16 KA - 01 No Microprocessor release with adjustable overload setting(Outgoing) (f) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 600/5A LT-CT operated complete - 01 Set (g) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc. The cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces | ||||||||||||
| 2.00 | S & F panel and its connections and supply and install, testing and commissioning of Out door LT feeder panel factory made cubicle 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar 450 Amps of suitable size, Al strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following :- | 1 | Each | 1,71,000 ₹1,71,000 | 2,50,000 ₹2,50,000 | 1,55,000 ₹1,55,000 | 1,66,320 ₹1,66,320 | 1,73,993 ₹1,73,993 | 1,44,200 ₹1,44,200 | 1,65,000 ₹1,65,000 | 1,40,000 ₹1,40,000 | 1,35,000 ₹1,35,000 Lowest |
| 2.01(a) MCCB 4 Pole 320 Amps 36 KA -01 Nos. Microprocessor release with adjustable overload setting (incomer) (b) MCCB 4 Pole 250 Amps 25 KA -01 Nos. Microprocessor release with adjustable overload setting (Outgoing) (c) MCCB 4 pole 160 Amps 25 KA - 02 Nos Microprocessor release with adjustable overload setting (Outgoing) (d) MCCB 4 Pole 100 Amps 16 KA - 02 Nos Microprocessor release with adjustable overload setting (Outgoing) (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 500/5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces | ||||||||||||
| 3.00 | Supply,installing,testing and commissioning, factory made and tested, LT panel board outdoor type,weather,vermin proof, cubical type, platform mounted, suitable for 415 volts,3 phase 4 wire 50hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 300amps rating,4 strips, the panel should be dust proof and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the outside and inside, cable glands and lugs for incoming and outgoing cable etc, independent chamber to accommodate incl plinth pf panel of suitable size complete all as specified and directed including following accessories:-
(a) changeover 200 Amp,415volts-01No(as incoming)
(b)MCCB 4 pole adjustable,63Amp,415 volts 16KA-03 Nos
(c)Indicating lamps(Set 03 Nos)-01set(R,Y & B)
(d) Digital panel mounted voltmeter & Ammeter flush type of size 96x96mm three
phase class.
(e) Panel wiring with suitable size PVC insulated heavy duty 1100volts grade single
core cable with copper conductor multistranded with cable end termination lugs. | 1 | Each | 1,17,000 ₹1,17,000 | 75,000 ₹75,000 | 1,15,000 ₹1,15,000 | 1,02,600 ₹1,02,600 | 1,03,663 ₹1,03,663 | 72,100 ₹72,100 | 98,000 ₹98,000 | 85,000 ₹85,000 | 36,358 ₹36,358 Lowest |
| 4.00 | Supply, Installation, test and Commissioning factory fabricated, out door type,LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following | 4 | Each | 36,000 ₹1,44,000 | 36,000 ₹1,44,000 | 38,000 ₹1,52,000 | 42,300 ₹1,69,200 | 53,663 ₹2,14,652 | 82,400 ₹3,29,600 | 29,000 ₹1,16,000 | 40,000 ₹1,60,000 | 26,000 ₹1,04,000 Lowest |
| 4.01(a) Aluminium bas bar 300amps - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 200 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 No | ||||||||||||
| 5.00 | Supply and lay in trenches / fixed to walls/ poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 volts grade armoured under ground cable with aluminium conductor of 4 core 10 sqmm incl taking out of existing cable all as directed | 630 | RM | 153 ₹96,390 | 145 ₹91,350 | 140 ₹88,200 | 135 ₹85,050 | 143 ₹90,090 | 123 ₹77,490 | 135 ₹85,050 | 110 ₹69,300 Lowest | 225 ₹1,41,750 |
| 6.00 | All as per item no 5.00 above but 4.0 Core 16 Sqmm | 630 | RM | 162 ₹1,02,060 | 165 ₹1,03,950 | 175 ₹1,10,250 | 162 ₹1,02,060 | 153 ₹96,390 | 133 ₹83,790 Lowest | 165 ₹1,03,950 | 140 ₹88,200 | 230 ₹1,44,900 |
| 7.00 | All as per item no 5.00 above but 3.5 Core 35 Sqmm | 300 | RM | 270 ₹81,000 | 260 ₹78,000 | 275 ₹82,500 | 261 ₹78,300 | 233 ₹69,900 | 206 ₹61,800 Lowest | 270 ₹81,000 | 220 ₹66,000 | 320 ₹96,000 |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
3 Apr 2025, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
SPECIAL REPAIR / REPLACEMENT TO CONVERSION OF LT OH LINE TO LT UG CABLE AT FEL, MCEME UNDER GE(U) SECUNDERABAD.
2025_MES_701362_1
GE (U)/SEC/TOKEN 50 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (UTILITY) SECUNDERABAD
₹63,000
Yes
6 Oct 2025
13 Mar 2025
10 Apr 2025
13 Mar 2025
3 Apr 2025
27 Mar 2025
Amount
(a) MCCB 4 Pole 400 Amps 36KA -01 No. Microprocessor release with adjustable overload setting (incomer) (b) MCCB 4 Pole 320 Amps 36KA -02 Nos. Microprocessor release with adjustable overload setting (Outgoing) (c) MCCB 4 Pole 200 Amps 25KA -01 No Microprocessor release with adjustable overload setting (Outgoing) (d) MCCB 4 Pole 160 Amps 25 KA - 01 No Microprocessor release with adjustable overload setting (Outgoing) (e) MCCB 4 Pole 100 Amps 16 KA - 01 No Microprocessor release with adjustable overload setting(Outgoing) (f) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 600/5A LT-CT operated complete - 01 Set (g) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc. The cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces
(a) MCCB 4 Pole 320 Amps 36 KA -01 Nos. Microprocessor release with adjustable overload setting (incomer) (b) MCCB 4 Pole 250 Amps 25 KA -01 Nos. Microprocessor release with adjustable overload setting (Outgoing) (c) MCCB 4 pole 160 Amps 25 KA - 02 Nos Microprocessor release with adjustable overload setting (Outgoing) (d) MCCB 4 Pole 100 Amps 16 KA - 02 Nos Microprocessor release with adjustable overload setting (Outgoing) (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 500/5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces
Supply,installing,testing and commissioning, factory made and tested, LT panel board outdoor type,weather,vermin proof, cubical type, platform mounted, suitable for 415 volts,3 phase 4 wire 50hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 300amps rating,4 strips, the panel should be dust proof and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the outside and inside, cable glands and lugs for incoming and outgoing cable etc, independent chamber to accommodate incl plinth pf panel of suitable size complete all as specified and directed including following accessories:- (a) changeover 200 Amp,415volts-01No(as incoming) (b)MCCB 4 pole adjustable,63Amp,415 volts 16KA-03 Nos (c)Indicating lamps(Set 03 Nos)-01set(R,Y & B) (d) Digital panel mounted voltmeter & Ammeter flush type of size 96x96mm three phase class. (e) Panel wiring with suitable size PVC insulated heavy duty 1100volts grade single core cable with copper conductor multistranded with cable end termination lugs.
Supply, Installation, test and Commissioning factory fabricated, out door type,LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following
(a) Aluminium bas bar 300amps - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 200 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 No
Supply and lay in trenches / fixed to walls/ poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 volts grade armoured under ground cable with aluminium conductor of 4 core 10 sqmm incl taking out of existing cable all as directed
All as per item no 5.00 above but 4.0 Core 16 Sqmm
All as per item no 5.00 above but 3.5 Core 35 Sqmm
All as per item no 5.00 above but 3.5 Core 50 Sqmm
All as per item no 5.00 above but 3.5 Core 70 Sqmm
All as per item no 5.00 above but 3.5 Core 95 Sqmm
All as per item no 5.00 above but 3.5 Core 120 Sqmm
All as per item no 5.00 above but 3.5 Core 185 Sqmm
All as per item no 5.00 above but 3.5 Core 240 Sqmm
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
S & F hot press moulded SMC junction / terminal box of size with internal dimensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed.
Supply and drawn sub main wiring with two runs of 1.5 Sq mm single core PVC insulated unsheathed cable up to and including 1100 volts grade with multistranded copper conductor drawn through and including non metallic PVC rigid conduit accessories surface type on walls, floors etc including one run of 1.5 Sqmm PVC insulated copper conductor for earth continuity wire all as specified. (Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only) (For Street Light connection from Junction Box to Street Light)
Supplying, erecting and fixing new steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply and fix steel light bracket made out of 40mm bore mild steel GI light grade tubing overall length 1.5m bend to shape as directed including providing 2 no's MS flat iron 40x6mm clamp of appropriate size with nut bolts washers duly painted with 2 coats of synthetic enamel paint over one coat of primer(GI surface shall not be painted) complete all as specified.
M&L for painting the existing LT steel poles of 9.0mtr long including cross arms,clamps,street light junction boxes etc with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle15cm with black paint on poles. Painting the poles up to 1.5mtr height with alternate bands 30cm height(3 Nos black and 2nos yellow)from ground level, complete all as specified and directed.
Dismantling LT steel tubular pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2(using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2(using 20mm graded stone aggregate) in both foundation and coping of poles all specified in SSR part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engr-in-charge.
Dismantling of damage/broken coping of PCC/steel pole of any size and removing the debris from site including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and coping of poles all as specified in SSR Part I-2009 complete all as directed by Engineer-in-Charge complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
All as per item No. 26.00 above here in before but depth above 1.5 m & below 3 m
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling riddled earth in trenches for cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down only shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I, flat, size 250x150x40 mm complete all as specified and directed.
M&L brick protection with common burnt brick sub class ‘B’ of size 230 x115 x75 mm for cable protection complete all as directed by Engr-in-charge.
M/L in repairs for cement concrete in foundation (1:4;8) type D2 using 40 mm graded broken stone aggregate for base of foundation complete as specified
M/L in repairs for cement concrete in foundation (1:3;6) type C2 using 40 mm graded broken stone aggregate including form work complete as specified
M/L in repairs for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
Dismantling insulators any type, any size
Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately)
Dismantling of ACSR or AAC conductors
Dismantling of Service wire of any size and type
VS ENTERPRISES (BID ID -3274641)
MS ENTERPRISES (BID ID -3275901)
L and S ENTERPRISES (BID ID -3272125)
SANJEEV CONSTRUCTIONS (BID ID -3275823)
SHANTI MARKETING AND SERVICES (BID ID -3272461)
Haasith constructions (BID ID -3275761)
DPS sales and services india (BID ID -3275648)
LEOENTERPRISES (BID ID -3275480)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .