Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC ROOM NO 281 GANESH MARUTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹11.0 L+₹1.5 L (16.4%)Rejected-Finance H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹12.5 L+₹3.1 L (33.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.3 L+₹6.9 L (72.9%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹19,400
Closing Date
16 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Provn of S/BY Power supply for iron R/T project at AF Stn Darbhanga under GE (AF) Bihta.
2022_MES_546172_1
8250/BHT/DBG/E8
Open Tender
Civil Works
Item Rate
150 days
Darbhanga
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹19,400
Yes
10 Nov 2022
18 Aug 2022
19 Sept 2022
18 Aug 2022
16 Sept 2022
30 Aug 2022
Amount
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 62.5 KVA, water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum with AMF panel. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Darbhanga (Bihar) (Capacity of Engine, alternators shall be worked out taking all de-rating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection ,multi cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 62.5 KVA(50KW) at outdoor atmospheric conditions at Darbhanga ,(Taking all de-rating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . Make - Kirloskar of model-Koel Green or equivalent in Cummins/Jakson/Ashok Leyland/Greev Cotton.
(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 62.5 KVA/50 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. Make - Kirloskar of model-Koel Green or equivalent in Cummins/Jakson/stem ford/Jyoti/NGEF.
(iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
(iv) AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 25X25X5 mm, and 1.6 mm thick MS CRCA sheet, front opening type , protection class IP-54, duly powder coated after seven tank process, with electrolytic grade copper bus bar of 300 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
(a) MCCB 415 Volts, 315Amp, rating 4 Pole 25 KA rupturing capacity, adjustble type 70% - 100% -2 No with suitable rating HRC back up fuses
(d) Phase indicating lamps(R-Y-B) -1 set
(e) Frequency meter digital type 45 to 55 HZ-1 no
(f) KWH Meter 3 Phase unbalanced load 1200 Amps capacity incl CT Coil -1 Set
(g) All standard relays , circuits and protection required for automatic operation of Gen set
(h) By pass arrangment of suitable cap
(V) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002..
(VI) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M
(VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set.
(VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 25x4mm, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 15 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply, install, testing and commission of out door type cubical feeder pillar box outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2.00 mm thich MS sheet and MS angle section 40x40x6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back open able double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, comprising of the following:- a) TPN, Copper bus bar 600 Amps insulated with colour coded heat shrinkable sleeve provided with Changer switch of amp same as incoming MCCB. b) Incoming MCCB 4 pole 400 Amps -01 Nos c) Outgoing MCCB 4 pole 125 Amps -04 Nos c) Outgoing MCCB 4 pole 100 Amps -02 Nos c) Indicator lamps RYB –01 S et d) Digital Voltmeter 0-500 volts 96 mm square flush pattern-01 No e) Digital Amp meter 0-400 Amps 96mm square flush pattern - 07 No
Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, spreaders, provision of extra holes in bus bar, provision of cable gland etc. (ii) All internal wiring shall be done with suitable size (iii) The panel shall be mounted on brick wall not less than the height of 0.6m of three sides and masnory work complete all as directed incl white washing for brick work.
Supply and laying & testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 95 Sq mm 3.5 core including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Excavation In trenches not exceeding 1.5 mtr. In depth and not exceeding 1.5 mtr. In width and getting out in soft/loose soil for laying of cables/pipes, erection of poles, stays, cable fault detection etc.
Returning re-filling of excavated soil after laying the cable with spreading leveling watering with ramming in layers not exceeding 25cm thick in loose/soft soil complete all as directed.
Removing excavated materials/ surplus soil and depositing where directed at a distence not exceeding 50 mtr.at a level not exceeding 1.5 mtr. from starting point.
Supply , lay / spread in trenches, River sand , clean ,including spreading , levelling , punning for laying / cushioning of cables all as specified and as directed.
M&L well burnt sub class “B” bricks laid flat breadth wise along the length of cable for cable protection complete all as specified and directed.
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed : (a) 50 mm bore
SHIV SHAKTI TRADERS
M/S Akash Enterprises
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .