| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-Finance | ₹19.9 L | L1 | Accepted-Finance L1 |
| 2 | L2₹20.2 LRejected-Finance | ₹20.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹20.4 LRejected-Finance | ₹20.4 L | L3 | Rejected-Finance L3 |
Tender Value
₹19.9 L
EMD Value
₹19,917
Closing Date
27 Mar 2026, 11:00 amClosed
Executive Engineer (Works) Z.P.Kolhapur
Executive Engineer (Works) Z.P.Kolhapur
CONSTRUCTION OF SAMAJIK SABHAGRUH AT-KODAVADE TAL-PANHALA DIST-KOLHAPUR (FUND-2515-1238 YEAR-2025/2026)
2026_KOLHA_1288561_6
E TENDER NOTICE NO 106/2025-26
Open Tender
Civil Works
180 days
KOLHAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹19,917
13 May 2026
20 Mar 2026
30 Mar 2026
20 Mar 2026
27 Mar 2026
20 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Empty boring for 425 milimetre to 500 milimetre diameter bored reinforced cement concrete cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metre, excetra complete. Item / Page No : 51 / 170 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. | ||||||
| 2Empty boring for 325 milimetre to 400 milimetre diameter bored reinforced cement concrete cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metre, excetra complete. Item / Page No : 50 / 170 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. | ||||||
| 3Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim bored pile of 450 milimetre diameter each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock,excluding provision of reinforcement including placing with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer), excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) by tremie arrangement compaction of concrete including chipping and dressing, excetra complete. (Excluding steel reinforcement) (using ARTIFICIAL SAND). Item / Page No : 10 / 160 Specification No : Bd.B.2 Spec. Page No : 269 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | ||||||
| 4 | Providing and laying cast in situ / Ready Mix Cement Concrete M-25 for single rim bored pile of 380 milimetre diameter each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock,excluding provision of reinforcement including placing with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer), excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) by tremie arrangement compaction of concrete including chipping and dressing, excetra complete. (Excluding steel reinforcement) (using ARTIFICIAL SAND).
Item / Page No : 9 / 160
Specification No : Bd.B.2
Spec. Page No : 269
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | - | Running Metre | 1 | - | BI01010001010000000000000515BI0100001115 |
| 5 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Manual Means
Item / Page No : 1 / 153
Specification No : Bd.A.1
Spec. Page No : 259 | 1 | Cubic Metre | 1 | ₹1 | BI01010001010000000000000515BI0100001116 |
| 6 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).
Item / Page No : 1 / 175
Specification No : Bd.E.1
Spec. Page No : 287-288
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, compacting, finishing and curing, excetrawith fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand, complete. (Excluding steel reinforcement) (using ARTIFICIAL SAND).
Item / Page No : 60 / 171
Specification No : Bd.F.1
Spec. Page No : 297
Additional Specifications : 1. The work shall be carried out as directed by Engineer-In-Charge. 2. With additional specifications for controlled concrete. 3. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | 1 | ₹1 | BI01010001010000000000000515BI0100001118 |
| 8 | Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 33 / 180
Specification No : Bd.F.5, B-7
Spec. Page No : 300, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete plinth beams as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand (using ARTIFICIAL SAND).
Item / Page No : 23A / 185
Specification No : Bd.F.12, B-7
Spec. Page No : 304-305, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 197
Specification No : Bd.G.1
Spec. Page No : 313
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. | 1 | Cubic Metre | 1 | ₹1 | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_2215427.xls
BOQ • 0.29 MB
SBD_2025_26.pdf
Tender Documents • 2.99 MB
Download all tender documents and submit your bid