Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.5 CrAccepted-AOC | ₹6.5 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹6.6 Cr+₹3.1 L (0.48%)Rejected-Finance | ₹6.6 Cr+₹3.1 L (0.48%) | L-2 | Rejected-Finance Not Validated. (Other than L-1) |
| 3 | L-3₹6.7 Cr+₹17.3 L (2.65%)Rejected-Finance | ₹6.7 Cr+₹17.3 L (2.65%) | L-3 | Rejected-Finance Not Validated. (Other than L-1) |
| 4 | L-4₹7.3 Cr+₹76.8 L (11.8%)Rejected-Finance | ₹7.3 Cr+₹76.8 L (11.8%) | L-4 | Rejected-Finance Not Validated. (Other than L-1) |
| 5 | L-5₹7.4 Cr+₹91.9 L (14.1%)Rejected-Finance | ₹7.4 Cr+₹91.9 L (14.1%) | L-5 | Rejected-Finance Not Validated. (Other than L-1) |
Tender Value
Refer Docs
EMD Value
₹7.4 L
Closing Date
23 Aug 2021, 6:00 pmClosed
CE SILIGURI ZONE
CE SILIGURI ZONE PO SALUGARA, PIN 734008
Completion of incomplete work of Provn of OTM Accn PH I at Tawang
2021_MES_455670_1
89411_TAWANG_RandC
Open Tender
Civil Works
Lump-sum
455 days
Tawang
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
GE TAWANG
₹7.4 L
Yes
23 Sept 2021
29 Jun 2021
25 Aug 2021
29 Jun 2021
23 Aug 2021
9 Aug 2021
30 Jun 2021 - 15 Jul 2021
Amount
BUILDING WORKS (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDING WORKS” as listed in Schedule ‘A’ Part-I Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,01,05,492.46.00 inserted by the MES in Schedule ‘A’ Part-I.
SITE CLEARANCE, EXCAVATION AND EARTH WORK (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,32,999.30 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER AND HOT WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER AND HOT WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,93,624.26 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 27,76,494.40 inserted by the MES in Schedule ‘A’ Part-IV.
EXTERNAL WATER SUPPLY (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,11,923.35 inserted by the MES in Schedule ‘A’ Part-V.
EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION (Sch 'A' Part-VI)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 25,17,203.30 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,42,000.99 inserted by the MES in Schedule ‘A’ Part-VII.
SEWAGE DISPOSAL (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,07,025.78 inserted by the MES in Schedule ‘A’ Part-VIII.
ROAD / PATH / CULVERT (Sch 'A' Part-IX)
Lump sum price worked out by the Contractor for “(ROAD / PATH / CULVERT)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 10,21,876.70 inserted by the MES in Schedule ‘A’ Part-IX.
SECURITY FENCING AND STEEL GATE (Sch 'A' Part-X)
Lump sum price worked out by the Contractor for “(SECURITY FENCING AND STEEL GATE)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,52,646.76 inserted by the MES in Schedule ‘A’ Part-X.
RETAINING WALL (Sch 'A' Part-XI)
Lump sum price worked out by the Contractor for “(RETAINING WALL)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,27,690.04 inserted by the MES in Schedule ‘A’ Part-XI.
DEMOLITION AND DISMANTLING (Sch 'A' Part-XII)
Lump sum price worked out by the Contractor for “(DEMOLITION AND DISMANTLING)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 0.00 inserted by the MES in Schedule ‘A’ Part-XII.
MISCELLANEOUS B/R & E/M ITEMS (Sch 'A' Part-XIII)
Supplying, fixing and testing of storage type water heater of capacity 25 litres, five star rated complete with heating element, thermostat valve, indicator neon lamp inlet and outlet assembly and all other accessories for connection and fittings on wall complete all as specified and as directed.
Supplying, fixing and testing of storage type water heater of capacity 50 litres. five star rated complete with heating element, thermostat valve, indicator neon lamp inlet and outlet assembly and all other accessories for connection and fittings on wall complete all as specified and as directed.
Material & Labour for earthing with copper earth plate electrode of size 60cmx60cm x3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the copper earth lead by means of bolts, nuts, check nuts and washers of copper strip 20x3mm as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in hard/ dense soil, returning filling, disposal of surplus soil. earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit coker made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10 mm dia TMT bar embedded in cover slab and cover. wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed.
Supplying, fixing, testing and commissioning of wall split type AC of capacity 2.0TR for heating and cooling facility complete with all accessories for connection and fittings complete all as specified and as directed. (Make: LG model No. LSA24ARMH L-Aura or equivalent make of model as per Appendix 'B'.
Supply and installation, commissioning and testing voltage stabilizer for automatic operation, single phase with neutral, air cooled indoor type and design for input voltage variation between 170 volt to 250 volt with output voltage stabilizer at 230 volt with accuracy of +/- 2.5% and capacity of 5KVA complete all as specified and as directed.
Supply and fixing 50mm bore cast iron air release valve with two air outlets and fixing up in PP-R water supply mains with suitable jointing materials complete all as specified and as directed.
Material and labour for cable route indicator over the LT cable made out of cast iron of dia 150mm and 12mm thick and marked with 'LT 1.1KV MES' on it, fixed with 40x6mrn MS strip upto length 200mm including 250mm x 250mm x 200mm PCC 1:2:4 type B-1 complete all as specified and as directed.
Supply, install, testing and commissioning junction box for street light made out of thermoplasticof size 240mm x 160mm x 110mm front door opening with locking arrangement with 1 No. connector for connecting incoming and outgoing of cable including provision of 1 No. of MCB SP 6 Amps to control the pole light circuit and MS brackets made out of 32x4mm flat for fixing the box to pole complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming and outgoing of cable complete all as specified and as directed.
Supply and fixing integral luminaires T5 lamp light fittings with and including 4 x 24 watts lamp, powder coated die cast aluminium housing with clear acrylic glass cover and accessories (IP-65) and other accessories fixed on pole with GI clamps of suitable size complete all as specified and as directed. (Make: Bajaj Model No. BTMB 424 complete or equivalent model of make as specified here-in-after.)
Supply and fixing main gate integral post top lanterns light luminairies with and including 1 x 150 watts lamp with copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and other accessories including 1.5sqmm, 3 core of not more than one metre length copper conductor watts lamp complete all as specified and as directed. (Make:- Bajaj Cat No. BJODCI 150 MH (E40) complete or equivalent model of make as specified here-in-after.)
Supply and fix for 160 mm nominal diameter of high density bore of high density polyethylene pipes (HDPE), PN 10 laid in trenches and jointed complete all as specified and as directed. (UNIT : RM)
Material and labour for liquid seal coat, applying evenly binder @ 9.8Kg/ XSqm blinding with 6.3mm size stone chippings @ 0.09 Cum/ XSqm and rolled to a uniform smooth surfaces with 8 to 10 tonne power roller complete all as specified and as directed.
OUTGOING (a) MCCB 300 Amps, capacity 25kA. TPN. 415 volts (Adjustable thermal type & Adjustable megnetic setting) - 02 Nos. (b) MCCB 200 Amps,capacity 25kA, TPN. 415 volts (Adjustable thermal type & Adjustable megnetic setting) - 02 Nos. (c) MCCB 63 Amps, capacity 25kA. TPN. 415 volts (Adjustable thermal type & fixed magnetic setting) - 02 Nos. (d) Street light electronic timer in with 03 Pole power contactor of rating min 16 Amps, 415 Volts - 01 No.
OUT GOING (a) MCCB 125 Amps. capacity 25kA. TPN, 415 volts (Adjustable thermal type & Adjustable megnetic setting) - 02 Nos. (b) MCCB 100 Amps.capacity 25kA, TPN, 415 volts (Adjustable thermal type & Adjustable megnetic setting) - 02 Nos. (c) MCCB 63 Amps, capacity 25kA. TPN, 415 volts (Adjustable thermal type & fixed magnetic setting) - 02 Nos. (d) Street light electronic timer with 03 pole power contactor of rating min 16 Amps, 415 Volts - 01 No.
OUTGOING (a) MCCB 125 Amps, capacity 25kA, TPN, 415 volts (Adjustable thermal type & Adjustable megnetic setting) - 02 Nos. (b) Street light electronic timer with 03 pole power contactor of rating min 16 Amps, 415 Volts - 01 No.
Material and labour for 25mm thick (consolidated thickness) bituminous premixed carpet consisting of 0.34 Cum/10 Sqm of stone chippings mixed with 18.25 Kg/10 Sqm of binder (paving bitumen) mixed in manual means, rolled with 8 to 12 tonne power roller to required camber and gradient complete all as specified and as directed.
Material and labour for construction of RCC culvert 1.5m span, PCC 1:2:4 type B2 in foundation, RR masonry wall, abutment wall, excavation in hard/ dense soil, PCC bed block, PCC 1:2:4 type B1 wear coat over slab, PCC 1:2:4 type B1 over water way, RR masonry parapet wall in CM 1:4, returning filling in removing of surplus soil and complete all as per TD drawing No. TD/NEZ/270, Sheet No.1/1. (UNIT : EACH JOB)
Supplying and fixing exhaust fan noiseless metal body 230mm sweep with louvers, AC single phase 230/240 volts including all accessories for connection and fittings complete all as specified and as directed.
Supply and fixing self ballasted 18 watts CFL lamp complete all as specified. (Note: 18 Watts lamp shall be used in lamp holder as given in Schedule 'A' Part-IV here-in-before.)
Supply, install, testing and commissioning of diesel engine driven generating set comprising of four stroke vertical cylinder water cooling, directly coupled with AC alternator self excited, self regulated and screen protected dust and vermin proof with static excitation system capable of rated 62.5KVA/ 50KW, 415 volts, 3 phase, 4 wire, 50HZ fixed on common strctural steel frame on anti vibration mounting pad including fuel tank with lines, 12 volts battery with starting arrangement etc. housed in and including sound proof accoustic enclosure canopy of suitable size as per manufacturer designe including control panel and necessary engine conforming to IS-10001/10002 and alternator as per IS-13364 including necessary PCC foundation, excavation. returning filling and removing surplus soil complete all as specified and comparing of the following:- (a) The engine shall be capable to stand de-rating factor of Tawang for 62.5 KVA rated output of alternator. (b) Fuel tank with level indicator having storage capacity not less than 8 (Eight) hours continuous running. (c) Silencer and exhaust pipe lagging with temperature and low lub oil pressure. (d) Engine safety protection for high water temperature and low lub oil pressure. (e) Gauge and meters such as lub oil pressure gauge, water temperature gauge, RPM meter. hour meter. etc.
Sub total
SHAMBHALA TRADERS
M/S L G BUILDERS
M/ S N T ENTERPRISES
M/S TSERING DHONDUP
M/S DNA HEIGHTS
M/S GLOBAL ROYAL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .