Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.4 L+₹78,405 (2.84%)Rejected-AOC NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹37.6 L+₹10.0 L (36.2%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹38.2 L+₹10.6 L (38.4%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.1 L+₹13.5 L (48.9%)Rejected-AOC 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-AOC Rejected |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
REPAIR/MAINT OF COOLING APPLIANCES UNDER GE GWALIOR
2023_MES_580783_1
CWE/JHA/GWL/TOKEN/100 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GWALIOR
As per tender documents
9 documents required · 9 mandatory
₹500
GE GWALIOR
₹96,000
Yes
30 Mar 2023
13 Feb 2023
18 Mar 2023
13 Feb 2023
13 Mar 2023
28 Feb 2023
Amount
Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from window type AC and S&F New compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed.
All as per Ser item No.1.00 above, but compressor suitable for window AC of capacity 2.0 Ton complete all as specified and directed.
Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from split type AC and S&F New compressor suitable for Split AC of capacity 1.5 Ton complete all as specified and directed.
All as per Ser item No.3.00 above, but compressor suitable for Split AC of capacity 2.0 Ton complete all as specified and directed.
M&L for testing leakage in system SplitWindow type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed.
All as per Ser item No 5.00 above, but Air conditioner of 2 to 3 ton capacity complete all as specified and directed.
M&L for servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed. Note for Ser Item No. 1.00 to 7.00 (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed. (ii). Spare parts alongwith Refrigerant gas shall be measured and paid separately there rate above Rs. 100/-.
The following items supply only :-
Starting capacitor of capacity 80/100 MFD
Starting capacitor of capacity 100/120 MFD
Condenser capacity of 5/6 MFD
Condenser capacity of 10 MFD
Condenser capacity of 36 MFD
Condenser capacity of 45 MFD
Condenser capacity of 50 MFD
Condenser capacity of 55 MFD
Heating Coil suitable for 1.5 Ton Capacity Window AC
Heating Coil suitable for 2.0Ton Capacity Window AC
Heating Coil suitable for 1.5 Ton Capacity Split AC
Heating Coil suitable for 2.0 Ton Capacity Split AC
Cooling Coil suitable for 1.5 Ton Capacity Window AC
Cooling Coil suitable for 2.0Ton Capacity Window AC
Cooling Coil suitable for 1.5 Ton Capacity Split AC
Cooling Coil suitable for 2.0 Ton Capacity Split AC
Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner
Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner
Swing motor suitable for 1.5 Ton Capacity Split type Air Conditioner
Swing motor suitable for 2.0 Ton Capacity Split type Air Conditioner
Over load relay suitable for 1.5/2.0 Ton Window type AC
Over load relay suitable for 1.5/2.0 Ton Split type AC
Electric blower motor suitable for 1.5 Ton Capacity Window type AC
Electric blower motor suitable for 2.0 Ton Capacity Window type AC
Electric blower motor suitable for 1.5 Ton Split AC (Evaporator/Condenser)
Electric blower motor suitable for 2.0 Ton Split AC (Evaporator/Condenser)
Blower motor fan blade suitable for 1.5/2.0 Window type AC
Blower motor fan blade suitable for 1.5/2.0 Split type AC
Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC
Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC
Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC
Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC
Air Filter Suitable for 1.5/2.0 Ton Capacity Window/Split type Air conditioner
Capillary tube length as per existing size suitable for 1.5/2.0 Ton Capacity Air conditioner
PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC
PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 split type capacity Air Conditioner
Repair of PCB of all type of AC.
Metal top with bottom suitable for 16 Amps Capacity 1.5/2.0/3.0 Ton Capacity Air conditioner as per site requirement.
Refrigerant gas R22/R-32 for topping up.
Refrigerant gas R 134(a) for topping up.
Refrigerant gas R 410(a) for topping up.
M&L for replacement of damaged Insulation in white colour with water proof of size 1/4&3/8 for Split AC complete as per existing site complete all as specified and directed.
M&L for replacement of damaged Insulation in white colour with water proof of size 1/2 & 5/8 for Split AC complete as per existing site complete all as specified and directed.
M&L for replacement of Rubber bush suitable for 1.5/2.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed.
M&L in servicing of inverter AC of capacity 1.5 Ton with pressure cleaning complete all as specified and directed.
M&L for replacement of Copper Tube of size 1/4 suitable for any type and any capacity Air conditioner complete all as specified and directed.
M&L for replacement of Copper Tube of size 3/8 and 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed.
Taking out and shifting new location and refixing both indoor and outdoor unit of split type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0/3.0 Ton in wall with rowl plugs including making holes for inlet /outlet in the wall with condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed.
S&F bracket for fixing of AC's complete all as specified and directed.
M&L for repairs to walk in cooler 1.5 Ton and repair/replacement the compressor, filter including gas charging and general service complete all as specified and directed.
S&F in repair of complete indoor unit of window/Split AC of capacity 1.5 Ton complete all as specified and directed.
S&F in repair of complete outdoor unit of window/Split AC 1.5 Ton complete all as specified and directed.
S&F in repair of complete indoor unit of window/Split AC of capacity 2 Ton complete all as specified and directed.
S&F in repair of complete outdoor unit of window/Split AC 2 Ton complete all as specified and directed.
S&F in repair of complete inverter type indoor unit of Split AC 1.5 Ton complete all as specified and directed.
S&F in repair of complete inverter type outdoor unit of Split AC 1.5 Ton complete all as specified and directed.
Dismantling and taking out the existing old unserviceable compressor any make from invertor type split AC and S&F New compressor suitable for inverter type Split AC of capacity 1.5 Ton complete all as specified and directed.
PCB Circuit suitable for inverter type Split AC of capacity 1.5 Ton complete all as specified and directed.
S&F In Repair Air Conditioner Outdoor Valve with size of 1/2 Inch L type (13mm) for 1.5 Ton complete all as specified and directed.
S&F In Repair Air Conditioner Outdoor Valve with size of1/4 Inch L type(13mm) for 1.5 Ton complete all as specified and directed.
S&F In Repair Air Conditioner Outdoor Valve with size of 1/4 Inch L type (13mm) for 2 Ton complete all as specified and directed.
S&F In Repair Air Conditioner Outdoor Valve with size of 5/8 Inch L type(13mm) for 1.5 Ton complete all as specified and directed.
S&F in Repair Copper wire with size of 2.5 Sqmm with 3 Core complete all as specified and directed.
S&F in Repair Copper wire with size of 2.5 Sqmm with 4 Core complete all as specified and directed.
Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F new compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, suitable for Water cooler of cooling capacity 40/80 ltrs/hrscomplete all as specified and directed.
All as per item No. 32 here in before but compressor suitable for Water Cooler of cooling capacity 150 ltrs/hrs complete all as specified and directed.
M&L for carry out through check up of the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.
The following items supply only :-
Blower fan motor SP,230V, 50 Hz suitable for 40/80, 60/120 capacity water cooler as per existng sample complete all as specified and directed.
All as per item here in before but suitable for 150/180 or equivalent water cooler as per existng sample complete all as specified and directed.
Capacitor for condenser motor suitable for any capacity, size complete.
Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
Thermostat switch with knob suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia .
Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity.
M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed.
M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed.
All as per Ser item No.37.00 above but compressor suitable for refrigerator capacity of 280 to 320 Ltrs complete all as specified and directed.
The following items supply only :-
Freezer suitable for 165 to 200 ltrs capacity Refrigerator
Freezer door suitable for 280 to 310 Ltrs capacity Refigerator
Relay current type and over load protector suitable for compressor complete.
Thermostat auto defrost type suitable for any make and any capacity Refrigerator single door.
Thermostat auto defrost type suitable for any make and any capacity Refrigerator double door.
Air Filter suitable for for any make and any capacity Refrigerator
S&F suitable timer for any capacity.
Electric blower motor suitable for 300 ltr refrigerater inverter type.
PCB Circuit suitable for 300 ltr refrigerater inverter type.
Heating sensor suitable for 300 ltr regrigerater inverter type
Thermostate suitable for 300 ltr regrigerater inverter type
Compressor suitable for 300 ltr regrigerater inverter type
Refrigerant gas R-600/R-290 in 150gm Can for topping up for regrigerater inverter type
M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed.
M&L carry out through check up the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed.
The following items supply only :-
Relay current type and over load protector suitable for compressor .
Thermostat auto defrost type suitable for any make and any capacity Deep Freezer
Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complte
Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity
Starting relay with overload suitable for 310/320 ltrs capacity Deep freezer
Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer.
Labour only for charging refrigerent gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and split type Air conditioner after duly rectifying leakages by welding/brazing and testng by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas to be measured and paid separately under relabent items of this schedule.
Dismantling and taking out the existing old unsv fan motor with blade including mounting brackets from Desert coolers and S&F new 3 speed fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable for D/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed.
The following items supply only :-
Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr.
Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size
Capacitor for 2.5/4MFD
Capacitor for 5/6 MFD.
Front panel repair of dimension as per existing size suitable for desert cooler of capacity 4000/5000/6000 Cum per hrs.
PVC Flexible hose suitable for desert cooler cooling system.
PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample.
Bolt, nut with washers as per sample
PVC Connector i.e (Elbow, Tee,3 way etc)
5 Amp Switch.
5 Amp Plug Top.
Monoplate with 5 Amp switch.
S&F top portion/cover of the desert cooler of the existing size.
Taking down the evaporative type desert coolers of Capacity upto 5000 Cum/hr by disconnecting all the electrical connections cleaning all the components by removing the side panels and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panel and reconnecting with electrical connections and writing the MES No complete all as specified and directed.
S&F leak prof desert cooler tank of size 29" x 14" made of 20 guage GI sheet complete all as specified and directed.
Complete Repairing/Servicing/Testing of Stabilizer with capacity of 2 KVA all as specified and directed.
Complete Repairing/Servicing/Testing of Stabilizer with capacity of 3 KVA all as specified and directed.
Complete Repairing/Servicing/Testing of Stabilizer with capacity of 4 KVA all as specified and directed.
Complete Repairing/Servicing/Testing of Stabilizer with capacity of 5 KVA all as specified and directed.
Taking down unsv ceiling fans(1200/1400 sweep)/Wall fan(450mm) 230v,AC supply,single phase from site,depositing in MES store Yard,dismantling all parts,checking serviceability of all parts & continuity of copper winding(Burn out winding fan should be staking aside for rewinding) including cleaning all the components of fan, oiling ,greesing,including replacement of rusted/unsv nuts,bolts split pin rubber reel,machine screws,shafts,capacitor,clamps etc as requried,reassembling the fan and testing complete all as specified and directed. Note :(i)Rewinding of fans should be measure and paid separately under appropriate items of schedule(ii) Major parts like fan capacitor,clamps with rubber real etc measured and paid separately as supply only items. (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Taking out burnt winding wire from ceiling fans/wall fans(Which req rewinding) Motor of 1200 mm sweep 230V AC supply,single phase,Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & sixe throughly cleaning all the components of fan, oiling,greesing,replacement of rusted/unsv nuts,bolts split pin rubber reel,machine screws,shaft etc as required reassembling the fan,testing complete & Transporting back to MES Yard complete all as specified and directed. Note :(i) Major parts like fan capacitor,clamps with rubber real etc measured and paid separately as supply only items as below. (ii) Testing should be done to repair fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Replacement in repair BLDC Kit for 1200mm Ceiling fan complete all as specified and directed.
Supply only in replacement of ball bearing(6201&6202) Suitable for Ceiling fan of any size complete all as specified and directed.
Capacitor for 3.15MFD complete all as specified and directed.
M/s Tirupati construction
Manish Electricals
M/s Sagar Construction
M/s Shanti Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .