Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 3 199 SHIV NAGAR RUI KI MANDI SHAHGANJ AGRA 282010 SHIV NAGAR RUI KI MANDI SHAHGANJ AGRA UTTAR PRADESH 282010 UDYAM UP 01 0010537 | AGRA | UTTAR PRADESH | 282010 | Admitted-Finance |
Tender Value
₹1.4 L
EMD Value
₹2,706
Closing Date
23 Oct 2023, 1:30 pmClosed
Executive Engineer (Elect.)
BSNL, Electrical Division, ALTTC, Ghaziabad
Repairing / Rewiring of Electrical fans and Fitting for leased out of Old T.E Bldg Auraiya, OA Etawah.
2023_BSNL_774461_1
36/EEE/BSNL/ED/GZB/2023-24
Open Tender
Miscellaneous Works
Item Rate
60 days
Etawah
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Account Officer Cash, B.S.N.L, O/o GMTD, Ghaziabad
₹2,706
2 Nov 2023
3 Oct 2023
25 Oct 2023
3 Oct 2023
23 Oct 2023
3 Oct 2023
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group 'A'
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
(b) 2 x 2.5 sq.mm. + 1 x 2.5 sq. mm earth wire
c) 2 x 4 sq.mm. + 1 x 4 sq. mm earth wire
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit etc as required. (a) 2 x 1.5 Sq. mm
b) 4 x 1.5 Sq. mm
c) 2 x 2.5 Sq. mm
d) 2 x 4 Sq. mm
Supplying and fixing of following size of steel conduit along with accessories in surface / recess i/c painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit etc as required. (a) 20 mm
Supplying and Fixing of following piano type switch/ socket in place of faulty components in existing switch board, Power points i/c connections etc as required. (a) 5/6 Amp single way Switch
(b) 3Pin 5/6 Amp Socket outlet
c) 15/16 Amp Switch
d) 6 pin 15/16 Amp Socket outlet
e) 180mmx100mmx60 deep MS box i/c phenolic laminated sheet cover etc
f) 200mmx250mmx60 deep MS box i/c phenolic laminated sheet cover etc
g) Phenolic laminated sheet cover in front suitable for 250mmx300mm x60 mm deep MS box etc
h) Phenolic laminated sheet cover in front suitable for 180mmx100mm x60 mm deep MS box etc
S/Fixing 20 watt LED 4 feet tube fitting suitable for single phase, 230 volts AC supply system connection etc complete as required.(M/s Cromption/ Philips or S.S make)
Replacement of following faulty components in existing 1x40 watt /2 x40 box/ MOR/ Patti type fitting i/c connections etc as required . (a) 36 watt / 40 watt Electronic Ballast (M/s Phillips or SS make)
(b) 4 feet 36 watt Fl Tube.(M/s Phillips or SS Make)
c) Batten Holder
d) 12 watt LED lamp
e) Electronic fan regulator ISI Marked
f) Starter for FL tube fitting
Supply & Fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 5/6 & 15/16 Amps socket outlet and 15/16 Amps piano type switch connection, painting etc. as required.
Supplying and fixing 2 way sheet steel enclosure dust protected, duly powder painted with 20 amps "C" curve, SP&N MCB on surface or in recess complete with connections, testing and commissioning etc. as required.
Rewinding & overhauling of following ceiling fans , replacement of bushes , bearing , shaft i/c capacitor etc complete as required .( Note :- Dismantalled copper wire shall be property of contractor , quote the rates accordingly ) (a) 1200/1400 mm ceiling fan single phase ,240 volt
Replacement of following faulty components by new ones in existing LT panel i/c connections, testing etc as required . (a) 63 Amp HRC Fuse for SFU (M/s HPL or SS make)
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [M/s Legrand or SS Make] (a) Single pole (5A to 32 Amp : C-series )
(b) Four pole MCB 63 Amp
Supplying & Fixing of energy efficient 30 watt LED Street Light with IP 66 protection complete with all accessories on the existing pole i/c connection with 1.5 Sq. mm copper conductor single core cable etc. complete as reqd.(Make:- Havells Sundown / Crompton /Philips make)
Providing ready made wall bracket for street light fitting for suitable size i/c fixing clamps, nut and bolts etc. as required.
Supplying and Laying of 2 x 1.5 sq. mm. copper conductor armoured cable PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on surface / recess / ground etc as required
Supplying & Fixing of 63 Amp 415 Volt TPN Switch disconnector fuse Unit ( M/s L&T Make : FN-63 or SS make) with sheet steel enclosur, HRC fuses and all accessories i/c connection etc complete as required )
Supplying & fixing of AC three phase static Energy meter of accuracy class 1.0, rating of 10-60 Amp, 3 x 240 Volt, 50Hz with backlit LCD display (Measure & display KWh only) with transparent hinged type box i/c making connection etc complete as required (M/s HPL make, Model TPPL1510000002OCN0)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as required a) Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Laying and fixing of one number existing PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of existing PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required a) 3½ x 25 sq. mm (28mm)
b) 3½ x 25 sq. mm (28mm) without gland
c) 3½ x 50 sq. mm (35 mm)
Supplying and fixing extra down rod of 75 cm length G.I. pipe,15 mm dia, heavy gauge , 2 x75 cm length wiring with 2 X 1.5 sq. mm FRLS PVC insulated,copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
M/s Mohit Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .