Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.8 L+₹11.3 L (32.6%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹46.9 L+₹12.4 L (36.0%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹43.5 L
EMD Value
₹86,960
Closing Date
8 Jun 2022, 6:00 pmClosed
GE Kapurthala
Kapurthala
Special Repair/Replacement of LT OH line with UG cable and Special repair to water supply installation at New/Old Mil Stn Kapurthala under GE Kapurthala
2022_MES_518980_2
GE KPT-10/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Kapurthala
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹86,960
Yes
12 Aug 2022
21 May 2022
10 Jun 2022
21 May 2022
8 Jun 2022
26 May 2022
Amount
Taking down carefully copper/ aluminium point wiring (light/ fan/bell/ socket or power point) complete inclusive of all fittings such as switches, ceiling roses, pendants, regulators, sockets, fittings etc. removing materials from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.
Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :-
(a) One light point controlled by one, one way switch
(b) One fan point controlled by one, one way switch
(c) One socket outlet 3 Pin, 5 Amp on independent board
(d) One socket outlet 3 Pin, 5 Amp on same board.
M&L for point wiring with 4.00 Sq mm single core multi-stranded copper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 120 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 4.00 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board.
S&F switch piano flush type single pole one way 5 Amp.
S&F switch piano flush type single pole one way 15 Amp.
S&F socket out let 2 in 1, 3 pin 5 Amp flush type.
S&F socket out let 2 in 1, 3 pin 15 Amp flush type.
M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body.
Taking down old unserviceable flourescent tube light fitting 36/40 watt fluorescent tube light fittings direct to walls or roof as ordered and disconnecting electrically with the electrical system and all materials required for the same. The rates also include making good the same to match with the existing surface.
Supply, installation, testing and commissioning of 20 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed.
Taking down old unserviceable bulkhead fitting & supply & fix bulkhead fitting decorative ceiling/wall mounted BULK HEAD with engineering plastic housing and top frame with opal PMMA diffuser suitable for 10 watt LED fittings of C&S electric or equivalent in model of Philips or Bajaj complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completeall as specified and as directed.
Taking down old unserviceable lamp holder and S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED lamp 9W.
Taking down old unsv DB and supply and fixing factory made sheet metal enclosure double door distribution board class IP-43 with 200 Amp rated copper bus bar 240 volts 8 way single pole and neutral link complete all as directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 6 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB)SPN 40 to 63 AMP poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Taking down carefully ceiling fan from existing location and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor, complete all as specifed and directed. Note: old Ceiling fan deposited to MES yard.
Supply and fixing Exhaust fan heavy duty of 300 mm sweep 1500 RPM complete all as specified and directed.
Taking down old unserviceable sub main wiring and M & L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6.00 Sqmm cable one run of 6.00 Sqmm cable as earth continuity conductor and one run of PVC Conduit shall be measured & paid as one unit.) Make : Havells/ polycab/Gloster.
M & L for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in gournd (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (Compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC M-20 nominal mix cover slab of size 450mm x 450mm reinforced with 8mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No. 3 of MES shedule of SSR Part-I complete all as specified and as directed. Each Set 8 2536.80 20294.40 SSR-19471.
Supply and fix Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 5 KVA capacity 50 KVA.
Supply and fix Star delta starter fully automatic suitable for 415 V AC 35 HP.
Supply and fix Star delta starter fully automatic suitable for 415 V AC 30 HP.
Supply and fix Star delta starter fully automatic suitable for 415 V AC 25 HP.
Supply and fix 4 Pole MCCB 100 Amp, 50 HZ,415 V with rupturing capacity 16 KA.
Supply only KEPRO 5 Ton 6 Mtr No of fall two chain pulley block.
Supply and fix Sluice Valve Class PN 1.6, 100 mm dia.
Supply and fix Sluice Valve Class PN 1.6, 150 mm dia.
Supply and fix reflex valves, PN 1.6,with by pass arrangement 150 mm dia.
Supply and fix cast iron air release valves PN 1.6, IS 14845 of size 80 mm dia bore and fixing up in cast iron water supply mains of size150 mm.
Taking down old GI coloumn pipe and S&F GI coloumn pipe 100 mm dia heavy duty 'C' class with flanged ends drill 3 meter including joining to exising main pipe line comlete al as specified and directed (the cost of nuts bolts washers packing materials and pressure gauge complete as specified and as directed.
Supply and fix Submersible cable copper 3 core 16 sqmm.
Supply and lay cable XLPE Insulated, galvanized steel or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core. Including taking down old cable, complete all as specified.
Supply only Rubber mat of size 1 m x 2 m x10 mm.
Dismantling/Taking out /down old unserviceable cross arms of MS channel and angle iron etc.
Dismantling/Taking out insulator of any type,any size.
Dismantling/Taking out old unserviceableACSR conductor/GI wire complete.
Taking out old unserviceable UG Cable of any sizes.
M&L for tube light grade GI laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etc for cable protection for the following size:-
(a) 40 mm nominal bore
(b) 50 mm nominal bore
Supply and lay cable XLPE Insulated, galvanized steel or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core.
-do- all as per item No 40 above but 16 sqmm, 2 core.
-do- all as per item No.40 above but 16 Sqmm 4 core.
-do- all as per item No.40 above but 25 Sqmm 4 core.
-do- all as per item No.40 above but 35 Sqmm 3.5 core.
-do- all as per item No.40 above but 50 Sqmm 3.5 core.
-do- all as per item No.40 above but 70 Sqmm 3.5 core.
-do- all as per item No. 40 above but 95 Sqmm 3.5 core.
S & F MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA, suitable for isolation, adjustable over load from 0.4-1.0In and adjustable short current from 2-12Ir also inbuilt ground fault protection available 20% to 100% of In complete all as specified and as directed by Engr-in-Charge.
S & F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA.
S & F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA suitable for isolation, adjustable over load from 0.4-1.0In and adjustable short current from 2-12Ir also inbuilt ground fault protection available 20% to 100% of In complete all as specified and as directed by Engr-in-Charge.
S & F MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 25 KA suitable for isolation, adjustable over load from 0.4-1.0In and adjustable short current from 2-12Ir also inbuilt ground fault protection available 20% to 100% of In complete all as specified and as directed by Engr-in-Charge.
S & F MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 25 KA suitable for isolation, adjustable over load from 0.4-1.0In and adjustable short current from 2-12Ir also inbuilt ground fault protection available 20% to 100% of In complete all as specified and as directed by Engr-in-Charge.
S & F Isolator 4 Pole, 415 V, fixed type, 63 Amps.
S & F in replacement of MCB SPN 32 Amps.
S & F in replacement of On load change over Switch 250 Amps, Modular construction, positive isolation and door interlock and padlock facility in sheet steel enclosure, complete all as specified and as directed by Engr-in-Charge.
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 9.0 metres long, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for fdn of poles, stay etc.
M&L for PCC 1:2:4 type B2 using 20mm graded for padestal coping incl necessary formwork finished fair using extra cement.
Supply & fixing energy saving LED street light 60 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lences with IP66 Protection. 10KV SPD included efficiency 110Lm/W, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories and suitable size bracket for hanging of light with 2 Nos clamp for fixing of GI pipe on pole with 3 core 2.5 sqmm PVC insulated aluminium cable upto control box to light fitting complete all as specified and directed by Engr-in-Charge.
Supply and fixing of PVC junction box factory made weather proof size 250mmx200mmx100mm for street/security light comprising of MCB 16 Amps -01 No SP, bus nar of 50 Amps rating aluminium for phase and neutral on porcelain based insulators with locking arrangement fixed to pole with MS clamps of size 20 x 3 mm , nuts, bots and washers complete all as specified and directed.
Earthing complete for transformer/VCB/ panels with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meters belownormal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GIstrip 32 mm x 6 mm in and including GI pipe 50 mm bore light grade as protection pipe (from top earth plate up to the test point) by means of GI bolts, nuts, check nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15 cm thick, all around including top and bottom and watering pipe 20 mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 mm x 300 mm x 300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20 mm graded stone aggregate and RCC cover ( 1:2:4) type B-1 using 20 mm graded crushed stone aggregate of 25 mm thick with 2 Nos MS handles of 12 mm dia including necessary excavation /earth work in any type of soil/rock and as shown in Electrical plate no 3 of SSR Part-I (2009) testing on completion complete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenches complete all as specified and directed.
Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed.
Material and labour for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed.
Gurjit const co
TARA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .