Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | ₹22.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹25.8 L+₹2.8 L (12.4%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | ₹25.8 L+₹2.8 L (12.4%) | L2 | Rejected-Finance Quoted amount is more than L1 |
| 3 | L3₹26.1 L+₹3.2 L (13.8%)Rejected-Finance | ₹26.1 L+₹3.2 L (13.8%) | L3 | Rejected-Finance Quoted amount is more than L1 |
| 4 | L4₹26.3 L+₹3.4 L (14.7%)Rejected-Finance | ₹26.3 L+₹3.4 L (14.7%) | L4 | Rejected-Finance Quoted amount is more than L1 |
| 5 | L5₹26.8 L+₹3.9 L (16.8%)Rejected-Finance | ₹26.8 L+₹3.9 L (16.8%) | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹21.1 L
EMD Value
₹42,500
Closing Date
14 Feb 2022, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
SPECIAL REPAIR OF BARBED WIRE FENCING WITH CHAIN LINK FROM BLDG NO T-52/05 TO TOWARDS NH-33 AT 23 INF DOU AND REWIRING ORS LINE BLDG NO P-95, 97 AND 98 OF 2 BIHAR AT NAMKUM MIL STN UNDER GE RANCHI
2022_MES_503677_1
8200/1387/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹42,500
Yes
14 Mar 2022
25 Jan 2022
16 Feb 2022
26 Jan 2022
14 Feb 2022
8 Feb 2022
Amount
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified and directed.
Excavation in trenches n.exc 1.5m deep & n.exc 1.5m wide on plan in ordinary soft/loose soil and getting out, complete all as specified and directed.
Dismantling fencing wire mash any type.
Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion post embeded in concrete and making good disturbed ground.
Demoliton of concrete of any description and any positon not otherwise specifically provided for.colmn/beams etc, complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, pillars, arches etc, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
M&L brick work with sub class' B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L PCC 1:3:6 type C-2 using 40 mm graded stone aggr as in foundation filling and mass concrete, complete all as specified and directed.
S&F Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type or standard rails straining balte, including securing or tying at crassing with provision of Galvanised mils steel wire staple pine etc, complete all as specified and directed. (each line wire to be mesured)
S&F MS angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming.
S&F Mild steel in flat, round bars, in available lengths quality con-forming to Fe- 290 (Gde E- 165).
Supply only 3.15mm dia GI wire 108x108 mm mesh (chain link fencing) made up to mattresses or cages lapped wired and laid in position including closing and tied with posts properly, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm long but n exc 150 mm & dia of neck 11 to 15mm, complete all as specified and directed.
Returning, filling in of soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
Removing surplus excavated earth (soil) to a distance n. exec 50m & depositing where directed at a level n. exec 1.5m above the starting point, complete all as specified and directed.
M&L reinforced cement concrete (nominal mix)1:1.5:3 type A1 (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M & L RCC (nominal mix) 1:1.5:3 type A-1 (20mm graded aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed.
Formwork to Square,rectangular or polygonal rough surface of concrete of sides of pillars, posts, struts, piers, columns and stanchions
M&L for Rendering 15mm thick in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished fair and even, complete all as specified and directed.
M&L 20mm thick Granite(of any type) tiles machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting , polishing & rendering 15 mm thick on brick or stone masonry surfaces finished fair and even to recieve tile in CM 1:4, complete all as specified and directed.
S&F TMT bars 10 mm dia and over, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
All as per item No 25 above, but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders.
Dismentling structural steel work including door, gates but excluding framed truss etc, complete all as specified and directed.
S&F framed work as in door or gates or angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. Door etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel, sheeting or other covering, running rail and guides) and hanging, also fastening and fixing complete all as specified and directed.
M&L for newly plastered surface of wall and applying two coats of cement based paint over a coat of white wash, complete all as specified and directed.
M&L for preparation of new steel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxide primer and applyinng 2 coats of synthetic enamel paint of approved shade, complete all as specified and directed.
Preperation of newly steel surface and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preperetion old painted surface of steel or iron work of any description material over 10 cm in width or girth of any description and applying one coat of synthetic enamel paint, complete all as specified and directed.
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for re use to be measured separetly including making good the disturbed portion/surface.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm with conceled Conduit with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch withsunken box of suitable size incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly, complete all as specified and directed.
All as per item No 34 above but for one 3/5 pin socket 5 Amp on independent board.with 1.5 Sqmm wire with 1.5 Sqmm earth wire.
All as per item No 34 above but for one 3/5 pin socket 5 Amp on same board, with 1.5 Sqmm wire with 1.5sqmm earth wire.
All as per item No 34 above but for 3 pins socket outlet 15 Amps independent with 4 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm, complete all as specified and directed.
S&F switch piano flush type/Bell push, 5 Amps, single pole one way. (Make : Anchor/Havells/ABB( ISI marked)
S&F socket 5 pins, 6 Amp, flush type piano (multi purpose). (Make : Anchor/Havells/ABB( ISI marked)
S&F Socket 15 Amps flush type 230 Volts, complete all as specified and directed. Make : Anchor/Havells/ABB ( ISI marked)
S&F switch 15 Amps flush type 230 Volts , complete all as specified and directed. (Make : Anchor/Havells/ABB ( ISI marked)
S&F 5 step fan regulator single pole, 240 Volts, complete all as specified & directed. (ISI marked) Make- Anchor/Havells/ABB
S&F ceiling rose, surface backlite, 65x50mm, three terminals, Make : Anchor ISI marked. Make : Anchor/Havells/Indoasian (ISI marked)
S&F angle lamp holder PVC/Polycarbonate base / back suitable for with LED bulb 10 W. (Make : Anchor/Havells/ABB ( ISI marked)
S&F LED Bulkhead 10W Fixture with Body made of Pressure Die Cast Aluminium Alloy housing with Clear Polycarbonate Opal Diffuser. Ingress Protection of IP65. with Driver having inbuilt Protection against Short Circuit Miswiring, Over Voltage and Surge Protection of up to 10kV. THD < 5 %, CRI>70. PF>.95.System Efficacy of the Product should be >85lpw( Total System Lumens > 800 lm). The Colour of the fixture should be in Silver Grey finish. The Fixture and Driver should be of the same Brand only.Operating Voltage Between ( 140-270)V. The Avg Life of Product Should be 50,000 Burning Hours @L70. The Fixture and Driver should be BIS Approved. The Engineer in Charge can take any Random Sample from Lot and send it for testing from any Govt Approved NABL Lab . The Cost of the same have to be borne by the Contractor. In case the sample is rejected the Whole lot will be rejected by the Department.Contractor will avail warrenty of 2 Years. Make- Havells/Bajaj/Crompton
S&F of LED Batten 10W With Body made of Extruded Aluminium Alloy housing and with Extruded Polycarbonate diffuser for optimum and Wide light distribution. Ingress Protection of Min IP 40 with Driver having inbuilt Protection against Short Circuit Miswiring, Over Voltage and Surge Protection of upto 6kV. THD < 5 %, CRI>80. PF>.95.System Efficacy of the Product should be >130lpw( Total System Lumens > 1300 lm). The Colour of the fixture should be in Grey finish. The Fixture and Driver should be of the same Brand only.Operating Voltage Between ( 140-270)V. The Avg Life of Product Should be 50,000 Burning Hours @L70. The Fixture and Driver should be BIS Approved. The Engineer in Charge can take any Random Sample from Lot and send it for testing from any Govt Approved NABL Lab . The Cost of the same have to be borne by the Contractor. In case the sample is rejected the Whole lot will be rejected by the Department. Contractor will avail warrenty of 2 Years. Make- Havells/Bajaj/Crompton
S&F of LED Batten 20W With Body made of Extruded Aluminium Alloy housing and with Extruded Polycarbonate diffuser for optimum and Wide light distribution. Ingress Protection of Min IP 40 with Driver having inbuilt Protection against Short Circuit Miswiring, Over Voltage and Surge Protection of upto 6kV. THD < 5 %, CRI>80. PF>.95.System Efficacy of the Product should be >130lpw( Total System Lumens > 2600 lm). The Colour of the fixture should be in Grey finish. The Fixture and Driver should be of the same Brand only.Operating Voltage Between ( 140-270)V. The Avg Life of Product Should be 50,000 Burning Hours @L70. The Fixture and Driver should be BIS Approved. The Engineer in Charge can take any Random Sample from Lot and send it for testing from any Govt Approved NABL Lab . The Cost of the same have to be borne by the Contractor. In case the sample is rejected the Whole lot will be rejected by the Department.Contractor will avail warrenty of 2 Years. Make- Havells/Bajaj/Crompton
S&F bed side lamp 3Watt LED lamp 3 Watt warm white size 14X14X37. Make - Phillips/Syska/Jaaguar
Dismantling and taking down existing unserviceable submain wiring from batten/conduit of any size and making good to disturbed surfaces to match the existing surfaces.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRSL sheathed cooper cable connecting to common earth dolly in and including heavy duty in concealed conduit including taking down old wiring all accessories complete all as specified and directed. Make- Havells/Finolex/Polycab
Dismantling and taking down existing unserviceable cable of any size and making good to disturbed surfaces to match the existing surfaces.
Supply & Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including taking down and laying with excavation, all laying mtrls, GI pipe, boring as per site requirment use for services connection as per specification, complete all as specified and directed. Make- Havells/Finolex/Polycab
Excavation in trenches n. exc 1.5 m wide & n. exc 1.5 m in depth for laying under ground cables/erection of pole and getting out in hard/dense soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removal of excavated surplus material (Soil) to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above the starting point, complete all as specified and directed.
M&L duct pipe double wall , corrugated HDPE 100mm dia outer dia , conforming to IS:14930 (Part- II) of approved colour with fittings for cable protection, complete all as specified and as directed. Make: Dutron/SFMC Pipe/Finolex
Taking down unservicable main switches MCB's DB's etc any type and capacity including making good the disturbed surfaces to match the existing.
S&F single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 08 ways. Make:-/Havells / Legrand / L&T .
S&F MCB SPN 32 to 63Amps 415V incl all termnials, fitting etc. Make:-Havells / Legrand / L&T .
S&F MCB SP 06 to 40 Amps 415V incl all termnials, fitting etc. Make:-/Havells / Legrand / L&T .
S&F MCB TPN 40 to 63 Amps 415V incl all termnials, fitting etc. Make:-/Havells / Legrand / L&T.
S&F Distribution board 12 way TP&N Vertical Loadline Double Door are fitted with Bus Bars, Neutral Links, Blanking Plates, Suitable for FP MCCB. Make:-Havells / Legrand / L&T
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .