Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC AT PO SURYA NAGAR HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹1.1 Cr Quoted ₹97.2 L | L1 | Accepted-AOC L1 BIDDER IS TECHNO COMMERCIALLY ELIGBLE |
| 2 | L2₹1.4 Cr+₹43.0 L (44.3%)Rejected-Finance AT BUDHIJAM COLONY ORIENT COLLIERY BRAJRAJNAGAR JHARSUGUDA ODISHA 768216 | JHARSUGUDA | ODISHA | 768216 | ₹1.4 Cr+₹43.0 L (44.3%) | L2 | Rejected-Finance REJECTED AS L2 |
| 3 | L3₹1.4 Cr+₹45.6 L (46.9%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | ₹1.4 Cr+₹45.6 L (46.9%) | L3 | Rejected-Finance REJECTED AS L3 |
| 4 | Rejected-Technical AT MAGURGANDAPATNA PO BHARATPUR P S KENDRAPADA DIST KENDRAPADA | CUTTACK | ODISHA | 754134 | - | - | Rejected-Technical rejected due to non submission of confirmatory documents |
Tender Value
₹1.5 Cr
EMD Value
₹1.9 L
Closing Date
7 Sept 2023, 5:00 pmClosed
Staff Officer(ENM), IB Valley Area
Office of Staff Officer(ENM), IB Valley Area
Day to day LT overhead line maintenance work at various points of mine along with providing assistance to cope up the daily emergency work in backshift hours at Samaleswari Open Cast Project, IB valley Area.
2023_MCL_286691_1
MCL/GM/IBV/ENM/etender/112089 Dated 22.08.2023
Open Tender
Electrical and Maintenance Works
Item Rate
731 days
SOCP, IB Valley Area
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.9 L
7 Dec 2023
22 Aug 2023
9 Sept 2023
23 Aug 2023
7 Sept 2023
23 Aug 2023
23 Aug 2023 - 31 Aug 2023
Amount
Item Description
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.(8 To 10 Mtr Height)
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required .
Erection of LV/MV shackle/pin insulator etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of stay set complete (galvanised) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Dismantling of stay set complete (galvanised) embedded in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .(0.55 Mtr Channel)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .(1.15 Mtr Channel)
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supply and Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Erection, Dismantling &checking of Light fittings of different ratings on LT Overhead line with connection, testing, transporation etc.
Loading and unlaoding of pole from SOCP IBVA to Site(To and Fro).
Supplying of M.S Nuts & bolts 5/8" X 3" , 3/8" X 2" etc of different sizes as required
Shifting of movable lighting tower (lowering of tower, transportation of tower, erction of tower & testing and giving power supply)
Shifting of Lighting Transformer (10KVA, 40KVA, 50 KVA, 100 KVA) including armoured cable with connection and disconnection on HT O/H line including binding.
Shifting of DG Set (7.5 KVA) including armoured cable with connection and disconnection on LT O/H line including binding.
Supply of PVC Twin Core aluminium Cable, 6 Sqmm, 1100 V, ISI Marked.
Erection and dismentaling of PVC Twin Core aluminium wire.
Assistance to cope up the daily emergency work in backshift (2nd shift and night shift) as per the requirement in mines for attending breakdown and rectification of electrical faults of overhead line to weighbridges, attending electrical faults in low tension overhead line and lighting circuits of mines area of SOCP IBVA for two years (720 days). Note: 1 Semi skilled labour and 1 unskilled labour in 2nd shift and 1 Semi skilled labour and 1 unskilled labour in night shift.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s BIKASH ENTERPRISES
M/S LIGHT PALACE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .