| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | ₹28.1 L | L1 | Accepted-AOC found lowest |
| 2 | L2₹28.8 L+₹69,315 (2.47%)Rejected-AOC OLD SABZI MANDI PATHANKOT M S NORTHERN INDIA CONSTRUCTION CO DHANGU ROAD VILLAGE TOWN PATHANKOT CITY PATHANKOT PATHANKOT PUNJAB 145001 INDIA | PATHANKOT | PUNJAB | 145001 | ₹28.8 L+₹69,315 (2.47%) | L2 | Rejected-AOC not found lowest |
| 3 | L3₹29.2 L+₹1.1 L (3.84%)Rejected-AOC | ₹29.2 L+₹1.1 L (3.84%) | L3 | Rejected-AOC not found lowest |
| 4 | L4₹30.7 L+₹2.6 L (9.22%)Rejected-AOC | ₹30.7 L+₹2.6 L (9.22%) | L4 | Rejected-AOC not found lowest |
| 5 | L5₹31.3 L+₹3.1 L (11.2%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹31.3 L+₹3.1 L (11.2%) | L5 | Rejected-AOC not found lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Dec 2023, 6:00 pmClosed
Maj Nitin Bisht
GE Basoli PO Lakhanpur Distt Kathua (JK) 184152
GE/BAS-65/2023-24 Repair and maintenance of OH UG cable LT panel ACSR conductor of Md accn and repair maintenance of STP and allied works at Basoli and Janglote under GE Basoli
2023_MES_631745_1
GE/BAS-65/2023-24
Open Tender
Civil Works
Item Rate
180 days
Basoli and Janglot area under GE Basoli
As per tender docs
8 documents required · 8 mandatory
₹500
GE Basoli
₹80,000
Yes
1 Feb 2024
8 Dec 2023
1 Jan 2024
8 Dec 2023
30 Dec 2023
23 Dec 2023
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and directed.
M&L for PCC ( 1 : 4 : 8 ) type D-2 using 40mm graded crushed stone aggreghate for foundation of poles and stay assembly complete all as specified and directed..
M&L for PCC ( 1 : 2 : 4 ) type B-1 using 20mm graded stone aggreghate for coping etc including necessary form work etc , complete all as specified and as directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 95 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 70 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 50 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 35 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 120 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade .complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 25 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade, complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 16 sqmm 4 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade, complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 16 sqmm 2 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
Taking out the old unsv cable in trenches or passing through pipe/fixed to pole/ wall XLPE insualted any size/core armourned heavy duty electric cable and removing from site complete all as specified and directed.
S & F 50mm bore Galvanised iron pipe 'light grade' for protection of underground cable laid in trenches or along pole/along wall/in PCC on GL/roof and including all fittings as required at site complete all as specified and directed.
S&F DWC high density polyethelene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site complete all as specified and directed.
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Punned thickness shall be measured)
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.
S&F in replacement aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps , jumpers etc complete of any size as per site requirement complete all as specified and directed.
S&F structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, including taking down old corroded structural steel complete all as specified and directed.
S & F shackle type,vitreous Insulator including one galvanised mild steel spindle, two galvanised iron washers,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,and complete all as specified and directed.
S&F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanised stay rod threaded with nuts, including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete including taking down U/S stay assembly complete all as specified and directed ( Note : Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately). .
S/F galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and directed
S/F loop type insulator with complete fiting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm complete all as specified and directed
Material and labour for painting of LT Steel/PCC poles with one coat of red oxide and two coat aluminium paitn complete all as Specified and directed.
Taking down Aluminium TPN busbar/Changeover any size and any capacity after disconnecting the electric supply and removing from site complete all as specified and directed.
S & F of aluminium TPN basbar chamber of capacity 100 amps, 415 volt with proper insulator mounting/routing in properly wall/surface with suitable PCC/Nuts & bolts complete all as specified and directed .
S&F in replacement of off load changeover switch in sheet metal enclosure four pole 100 Amps capacity suitable for 415 volt, 50 Hz with side operating handle complete with connected fixing arrangement switches, fastness, gutties etc. for fixing the same on wall / panel etc complete all as specified and directed.
S&F in replacement of off load changeover switch in sheet metal enclosure four pole 63 Amps capacity suitable for 415 volt, 50 Hz with side operating handle complete with connected fixing arrangement switches, fastness, gutties etc. for fixing the same on wall / panel etc complete all as specified and directed.
M&L for Earthing complete with GI earth plate electrode 60x60cmx6.3mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip 25x4 mm size protected by GI pipe light grade 15mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 metre from earth pit, common salt, charcoal dust and connected to panel bd/DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed.
Taking down unsv outdoor LT panel with MCCB after disconnecting the electric supply and removing from site complete all as specified and directed.
Supply and , erecting, and fixing in position, steel tubular swaged and welded poles of type 410 SP-31, 9 mtr long, IS-2713 marked, with mild steel base plate (fillet welded to poles), bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 05 Nos band/strip with fluorescent, PO box red synthetic enamel paint and alternate white strip (30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, complete all as specified and directed. Note : (i) Excavation, earth work and PCC will be measured and paid for separetely under respective items of Schedule 'A'. (ii) Poles shall be swaged and welded at manufacturer's factory and not at site. The inner surface shall be factory painted. complete all as specified and directed
Supply and laying for 80 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 50 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend, elbows, sockets reducer, nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 40 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 25 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and laying for 20 mm bore dia of Galvanised iron tubing "Medium grade" laid in trench, walls and ceilings or laid in floors with all fittings such as tees,bend,elbows,sockets reducer ,nipples and union including taking out old unserviceable GI tubing complete all as specified and directed.
Supply and fix in repair for 25 mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repair for 20 mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 20 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse including replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 10 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse including replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 7.5 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse including replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 5 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse including replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 3 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse including replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed
Material and Labour to repair / maint of unsv booster/ centrifugal pumps of 2 HP capacity and dismantling and strip opening to complete booster/centrifugal pump under mention cap and segrigated all serviceable parts and kept at site for reuse including replacement of bronze impellar of suitable size and bushes bearing and other required parts and making serviceable to the pump complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 20HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse including rewinding motor with supper enamled copper wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed .
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 10HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse including rewinding motor with supper enamled copper wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed .
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 7.5HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse including rewinding motor with supper enamled copper wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed .
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 5HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse including rewinding motor with supper enamled copper wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed .
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 3HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse including rewinding motor with supper enamled copper wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed .
Material and Labour to repair / maint of unsv booster/ centrifugal pumps motor electric driven for 2HP capacity and dismantling and opening complete motor under mention cap and segrigated all serviceable parts and kept at site for reuse including rewinding motor with supper enamled copper wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and varnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same after testing complete all as specified and directed .
Supply & Fix MCCB 160 Amps 415 Volts 25 KA four pole, 50 hz megnetic fix type complete all as specified and directed
Supply & Fix MCCB 100 Amps 415 Volts 16 KA four pole, 50 hz megnetic fix type complete all as specified and directed
Supply & Fix MCCB 63 Amps 415 Volts 16 KA three pole, 50 hz megnetic fix type complete all as specified and directed
Supply & Fix MCCB 32 Amps 415 Volts 16 KA three pole, 50 hz megnetic fix type complete all as specified and directed
Supply & Fix MCB Triple pole 32 Amps 415 Volts 10KA complete all as specified and directed
Supply & Fix MCB Triple pole 16 Amps 415 Volts 10KA complete all as specified and directed
M&L for painting of CI/MS pipe of any size ie 200 mm/150 mm/100 mm dia with one coat of red oxide primer and two coats of synthetic enamel black & blue paint and to match with existing colour coating complete all as specified and directed.
M&L for painting of Dual Media filter with one coat of red oxide primer and two coats of Aluminium paint to match with existing colour coating complete all as specified and directed.
Supply & Fix Contactor ML3. complete all as specified and directed.
Supply & Fix contact kit for ML3 contactor complete all as specified and directed.
Supply & Fix contact kit for ML2 contactor complete all as specified and directed.
Supply & Fix Spare coil for ML2 contactor. complete all as specified and directed.
Supply & Fix Electronic timer (Type ET-100 of 9 to 30 sec of complete all as specified and directed.
Supply & Fix overlod relay MN5 of L&T (Range 10-15 A) complete all as specified and directed.
Supply & Fix overlod relay MN5 of L&T (Range 15-30 A) complete all as specified and directed.
M/s Northern India Construction co
Durga Electricals
G.M. ENGINEERING SERVICES
kailu construction co
KALSI CONSTRUCTION CO
M/S SURINDER KUMAR MAHAJAN
M/s. Aggarwal Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .