| 1 | 1₹24.4 LAccepted-AOC 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹32.7 L+₹7.7 L (30.8%)Rejected-Finance ROOM NO 281 GANESH MARUTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | 2 | Rejected-Finance Being other than L-1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Jul 2022, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR /MAINT OF ENERGY METER, VTPN DB, EARTHING, GATE LIGHT AND CONNECTED ITEM UNDER GE (EAST) LUCKNOW
2022_MES_533641_1
GE/E/LKO/T-21 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹60,000
Yes
1 Nov 2022
25 Jun 2022
1 Aug 2022
25 Jun 2022
30 Jul 2022
16 Jul 2022
Amount
Taking down carefully by disconnecting Electrical connection and unscrewing from boards/outlet boxes, U/S electric meters of any locations and deposited to MES store yard as per bldg inventry by sub div and complete all as specified and directed.
Supply, installation, testing & commissioning in replacement of 1 Phase, 2 Wire, Energy Meters complete all as specified and directed.
Supply, installation, testing & commissioning in replacement of 3 Phase, 2 Wire, Energy Meters complete all as specified and directed.
Taking out Jumping/Fast & Slow Running complaint meter and fixing master meter monitering reading of 5 days and refixing of serviceable meter as per the different location complete all as specified and directed. Note : (i) Master meter will be provided by the contractor including all electrical connections (ii) 5 days readings shall be submitted by the contractor to Engineer - In - Charge .
Supply & fixing concealed sheet metal enclosure for Electric meter having space for one meter with transparent fiber glass door with seal & water and fire proof including cutting wall, plaster, matching color wall, and good finishing complete all as specified and directed.
Supply & fixing concealed sheet metal enclosure for Electric meter having space for Four meter with transparent fiber glass door with seal & water and fire proof as per sample complete all as specified and directed.
Supply & fixing concealed sheet metal enclosure for Electric meter having space for Six meter with transparent fiber glass door with seal & water and fire proof as per sample complete all as specified and directed.
Supply & fixing concealed sheet metal enclosure for Electric meter having space for Eight meter with transparent fiber glass door with seal & water and fire proof as per sample complete all as specified and directed.
Fixing only Electrical meter including all electrical connections complete all as specified and directed. Note:- Servicelable meter issued from MES store .
S&F in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed Make :-Legrand, Cat No. 5077 50 & 5079 38 or equivalent in Hager, Cat No : VYV04PM & VYV00E or Schneider, Cat No : A9HVD04M & A9HVDXXWB and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. Make :-Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No : HDA126Z or Schneider, Cat No : LV516312 (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos. Make :-Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No. NCN106N to NCN132N or Schneider, Cat No. A9N1P06C to A9N1P32C
S&F in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 08 way with 200 Amp rated copper bus bar with double door, IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways, vertical type, IP 43, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing as in repair MCB DB TPN (double door) 8 Ways, vertical type, IP 43, 415 Volts including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed .
S&F in replacement MCCB four pole 415 volts 160 Amps rupturing capacity 36KA complete all as specified and directed.
S&F in replacement MCCB four pole 415 volts 160 Amps rupturing capacity 25KA complete all as specified and directed.
S&F in replacement MCCB four pole 415 volts 100 Amps rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement MCCB four pole 415 volts 63 Amps rupturing capacity 16 KA complete all as specified and directed.
Supply and fixing in repair MCB TPN, 40 to 63 Amps, 240 Volts complete all as specified and directed.
Supply and fixing in repair MCB SPN, 32 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed.
Supply and fixing in repair MCB SP, 06 to 32 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
M&L for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
M&L for sub main wiring with 16 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 16 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Materials and labour for repairing of the earthing complete with diging and filling the salt and charcole 5-10 kg refiling sand including chamber plaster, providing the RCC cover of the required size including all neccessary work complete all as specified & directed..
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wir 4 sqmm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion complete all as specified and directed.
Taking out unserviceable gate light and supply and fix LED gate light 40w for existing gate complete all as specified and directed. Make :- Havells Cat Part No. RUBYPT40WLED757PSYMTOPC or Crompton LPTO-40-CDL as approved by GE .
Taking out unserviceable wire & Supply and fix 2x10 Sqmm PVC aluminium cable for gate light complete all as specified and directed.
Taking out old GI pipe in existing gate pillar and Supply and fix GI pipe of 40mm dia including plaster to match surface of pillar complete all as specified and directed.
ARTI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .