Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC Accepted and admitted being L1 | |
| 2 | L2₹48.0 L+₹83,029.20 (1.76%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹66.5 L+₹19.3 L (41.0%)Rejected-Finance CHHATABAD HABIB MENSION KATRASGARH DHANBAD DHANBAD 828113 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828113 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹48.4 L
EMD Value
₹96,800
Closing Date
5 Apr 2022, 6:00 pmClosed
GE (North)
GE (North) Meerut Cantt PIN 250001
MAINTENANCE REPAIR TO EOT AND HOT CRANES OF 510 ABW UNDER GE NORTH MEERUT CANTT
2022_MES_512572_1
8308/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Class D
Category C iii / b i
13 documents required · 13 mandatory
₹500
GE (North)
₹96,800
Yes
2 May 2022
8 Mar 2022
7 Apr 2022
8 Mar 2022
5 Apr 2022
22 Mar 2022
Amount
Maintenance and repair/regular and periodical servicing of crane EOT/HOT hoist/winch including fault finding of cranes, cleaning/servicing , welding of parts, Breakdown Maintenance/load testing of the crane and replacement of mechanical spares/parts of electrically /hand operated overhead travelling (EOT / HOT / JIB ) cranes , double box, girder type with electric motor for long travel,cross travel, hoisted ,controle pannels,protective pannels ,gear box , gantry rail ,main switches ,resistance coil,wire rope ,rope drum ,brake controle, cable and switches etc for the following capacity of crane at 510 ABW. Notes - (i) Spare parts required will be measured and paid seperately. EOT crane 20Ton (ii) After carrying out repairs as above, contractor has to submit the load testing certificate from authrorized OEM/ Company to ascertain the full functionally of the crane of any size & capacity.
All as per Srl item No 01 here-in-before but EOT crane 10Ton
All as per Srl item No 01 here-in-before but EOT crane 5 Ton
All as per Srl item No 01 here-in-before but EOT crane 3Ton
All as per Srl item No 01 here-in-before but EOT crane 2 Ton
All as per Srl item No 01 here-in-before but EOT crane 1 Ton
All as per Srl item No 01 here-in-before but Electrically operated hoist crane 3.2 Ton
All as per Srl item No 01 here-in-before but Electrically operated hoist crane 1 Ton
All as per Srl item No 01 here-in-before but Electrically operated hoist crane ,0.5Ton
All as per Srl item No 01 here-in-before but Electrically operated hoist crane 0.25 Ton
All as per Srl item No 01 here-in-before but Winch electrically operated 8 Ton tractive capacity
All as per Srl item No 01 here-in-before but HOT crane 2 Ton
All as per Srl item No 01 here-in-before but Hand operated under sling Chain pully block 1 Ton
All as per Srl item No 01 here-in-before but JIB CRANE 2 Ton
All as per Srl item No 01 here-in-before but JIB CRANE 1 Ton
S&F combination fuse switch double break in sheet steel enclosure conforms to IS/IEC 13947-3 rated voltage -415 volts AC 50 Hz type TPN of capacity 63 amps complete all as specified and directed.
S&F combination fuse switch double break in sheet steel enclosure conforms to IS/IEC 13947-3 rated voltage -415 volts AC 50 Hz type TPN of capacity 100 amps complete all as specified and directed.
S&F combination fuse switch double break in sheet steel enclosure conforms to IS/IEC 13947-3 rated voltage -415 volts AC 50 Hz type TPN of capacity 200 amps complete all as specified and directed.
Disconnection/ dismantaling of UNSV MCCB cover box from the site and Supply & Fixing fabricated MS Box (300 mm x 400 mm) of suitable size to cover/accommodate existing MCCB 3/4 pole upto 400 Amp surface mounted MS box made out of 16 SWG MS sheet having 4 pole at Top and bottom side to entry core of the cable using cable entry for connection of incoming and out going cable cutting at front side of box to be free the Knob of the MCCB and providing front door with locking arrangenment including power coated paint over a coat of primer inclding fixing the MS box the wall / channel by grouting of bolt nuts and warsher 4 sets using ravel plug and necessary fixing accessories and making all incoming and outgoing connection of MCCB complete all as specified and directed. ('C' frame FE,400A)
Supply and Replace Moulded case circuit breaker 415 volts 4 pole ,50 C/S, AC having rupturing capacity 50 KA & normal current rating 400 Amp complete all as specified and directed.
All as per Srl item No 20 here-in-before but current rating 250 Amps,4 pole and 36 KA rupturing capacity.
All as per Srl item No 20 here-in-before but current rating 200 Amps, 4 pole 36 KA rupturing capacity.
All as per Srl item No 20 here-in-before but current rating 63 Amps 25 KA rupturing capacity, 4 pole
Supply and Replace Moulded case circuit breaker 415 volts 3 pole ,50 C/S, AC having rupturing capacity 35 KA & normal current rating 400 Amp . complete all as specified and directed.
All as per Srl item No 24 here-in-before but current rating 250 Amps, 3 pole 36 KA rupturing capacity.
All as per Srl item No 24 here-in-before but current rating 320 Amps, 3 pole 36 KA rupturing capacity.
All as per Srl item No 24 here-in-before but current rating 200 Amps, 3 pole 36 KA rupturing capacity.
All as per Srl item No 24 here-in-before but current rating 100 Amps 3 pole 25 KA rupturing capacity,
Supply and Replace Single phase Preventer for motor protection of EOT cranes complete all as specified and directed complete all as specified and directed.
Supply and Replace LT under ground XLPE insulated armoured heavy duty and PVC sheathed aluminium stranded conductor cable 1100 V grade (for laid in the ducts, fixed on wall, roofs and trusses with clips including necessary accessories like copper lugs, cable entry glands, suitable size of bolts / nuts / washers etc) complete of size 50 Sqmm 3 1/2 Core complete all as specified and directed.
All as per Srl item No 30 here-in-before but 35 Sqmm 3 1/2 Core
All as per Srl item No 30 here-in-before but 25 Sqmm 3 1/2 Core
All as per Srl item No 30 here-in-before but 70 Sqmm 3 1/2 Core
All as per Srl item No 30 here-in-before but 95 Sqmm 3 1/2 Core
Supply and Replace Phase LED indicator ( RYB) complete all as specified and directed.
Material and labour for Rewinding hoist motor, Long Travel / Cross Travel motor any other motor fixed at any height with super enameled copper winding wire of Capacity 0.5 HP to 7.5 HP motor including dismantling / taking down of old U/S from any height complete all as specified and directed.
All as per Srl item No 36 here-in-before but capacity 7.5 HP to 17.5 HP motor
Supply and Replace Pendent box, 6 way of existing size (suitable to accomodate 6 Nos push buttons), box fabricated made out of 18 SWG MS sheet having one hole at top to connect the pendent cable using cable entry glands and two side hooks on the top of either side for holding the chain guard of pendent cable, fixing metal outer cover required push button (Red and green) duly prewired inside the pendent box having rear door opening and locking arrangement incl two coat of synthatic enamel paint of approved colour over a coat of primer complete all as specified and directed
All as per Srl item No 38 here-in-before but 8 way
All as per Srl item No 38 here-in-before but 12 way
Supply and Replace Push button mushroom head / Hexagonal type (Red or Green colours ) complete all as specified and directed.
Supply & fixing off load change over switch 415 volts,50 Hz in sheet metal enclosures four pole of capacity 100 Amps,04 pole side handle operated complete all as specified and directed
Supply & fixing off load change over switch 415 volts,50 Hz in sheet metal enclosures four pole of capacity 200 Amps,04 pole side handle operated complete all as specified and directed
S & F in repairs, connect, switch disconnector with kit kat fuse in metallic enclosure 415 V, TPN, 200 Amps complete all as specified and directed
All as per Srl item No 44 here-in-before but 100 Amps
Supply & fix in repair PVC wire insulated, unsheathed copper conductor double core, 4 sqmm 1100 Volts grade, multi stranded, FR- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990. complete all as specified and directed
Supply & fix in repair PVC wire insulated, unsheathed copper conductor double core, 6 sqmm 1100 Volts grade, multi stranded, FR- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 complete all as specified and directed
Supply & fix in repair PVC wire insulated, unsheathed copper conductor double core, 10 sqmm 1100 Volts grade, multi stranded, FR- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 complete all as specified and directed
Supply and fix in replacement AC Contactor Freedom Series type 4 pole with 415 volts with coil 110 volts as per existing auxiliary contact block with 02 No + 2 NC and current rating 16 Amps complete all as specified and directed
Supply and fix in replacement AC Contactor Freedom Series type 4 pole with 415 volts with coil 110 volts as per existing auxiliary contact block with 02 No + 2 NC and current rating 25 Amps complete all as specified and directed
Supply and fix in replacement AC Contactor Freedom Series type 4 pole with 415 volts with coil 110 volts as per existing auxiliary contact block with 02 No + 2 NC and current rating 40 Amps complete all as specified and directed
Supply and fix in replacement AC Contactor Freedom Series type 3 pole with 415 volts with coil 110 volts as per existing auxiliary contact block with 02 No + 2 NC and current rating 40 Amps complete all as specified and directed
Supply and fix in replacement AC Contactor Freedom Series type 4 pole with 415 volts with coil 110 volts as per existing auxiliary contact block with 02 No + 2 NC and current rating 70 Amps complete all as specified and directed
Supply and fix in replacement AC Contactor Freedom Series type 4 pole with 415 volts with coil 110 volts as per existing auxiliary contact block with 02 No + 2 NC and current rating 140 Amps complete all as specified and directed
Supply and Replace AC Solenoid Brake assembly, size 7" suitable for 10 to 20 Ton capacity EOT Cranes testing of crane on full load complete all as specified and directed
Supply and Replace Solenoid Brake assembly, size 4" suitable for 2 to 3 Ton capacity EOT Cranes testing of crane on full load complete all as specified and directed .
Supply and Replace AC Solenoid Brake assembly, size 5" suitable for 3 to 5 Ton capacity EOT Cranes testing of crane on full load complete all as specified and directed
Supply and Replaces set of two brass gear ( as per existing gear/ sample ) duly casted / fabricated and cutting teeth as required suitable to accommodate in the cranes Gear Box complete and capacities / sizes of cranes 1 to 2 Ton complete all as specified and directed
All as per Srl item No 58 here-in-before but 0.25 to 0.50 Ton capacity of crane
All as per Srl item No 58 here-in-before but 3 to 5 Ton capacity of crane
All as per Srl item No 58 here-in-before but 10 Ton capacity of crane
All as per Srl item No 58 here-in-before but 20 Ton capacity of crane
Supply and Replace Bearing bracket of size up to 20 ton EOT crane as per existing gear box (or as per sample) complete all as specified and directed
Supply and Replace Tapper Roll Bearing of No 30232/30226/30216/ 30205/30215/33207 or any other size as per existing gear box bearing complete all as specified and directed
Supply and replace Aluminum lugs up to 20 ton EOT crane of size 35 sqmm a complete all as specified and directed
All as per Srl item No 65 here-in-before but 50 Sqmm
All as per Srl item No 65 here-in-before but 70 Sqmm
All as per Srl item No 65 here-in-before but 95 Sqmm
Supply and replace Copper lugs up to 20 ton EOT crane of size 35 sqmm a complete all as specified and directed
All as per Srl item No 69 here-in-before but 50 Sqmm
All as per Srl item No 69 here-in-before but 70 Sqmm
All as per Srl item No 69 here-in-before but 95 Sqmm
Supply and replace of tie for binding of wire cables 6" any size of cranes complete all as specified and directed
All as per Srl item No 73 here-in-before but 8 "
All as per Srl item No 73 here-in-before but 12 "
Supply and replace of porcelin kit kat of size 16 Amps complete all as specified and directed
All as per Srl item No 76 here-in-before but 32 Amps
All as per Srl item No 76 here-in-before but 63 Amps
Supply and replace of binding wire 8 SWG complete all as specified and directed
Supply and Replace Gear oil (20W40) any other grade approved by manufacturer suitable for crane gear box complete all as specified and directed
Supply and Replace Sealed container in 10Kg packing grease suitable for crane gear box complete all as specified and directed
Supply and Replace Oil Seal (As per sample) suitable for crane gear box upto 20 ton crane complete all as specified and directed
Supply and Replace Coupling and foundation nuts, bolts washer hot drawn steel size of bolts will be 75mm length, 16mm dia, or as per existing suitable size of nuts,bolts & washer ( as per sample) complete all as specified and directed
Supply and Replace Male & female insulator made out of bakelite sheet 6mm thick round in shape 50mm dia duly drilled 20/22mm hole in center suitable for round bus collector unit / bus bar for EOT crane complete all as specified and directed.
Supply and Replace Male & female insulator made out of bakelite sheet 6mm thick round in shape 30/32mm dia duly drilled 10 to 15mm hole in center suitable for round bus collector unit / bus bar for EOT crane complete all as specified and directed.
Supply and Replace Male & female insulator made out of bakelite sheet 6mm thick round in shape 25/26mm dia duly drilled 10 to 15mm hole in center suitable for round bus collector unit / bus bar for EOT crane complete all as specified and directed.
Supply and Replace Brake coil, epoxy coated 440 volts suitable for EOT crane capacity 20 Ton suitable for 7" breake assembly complete all as specified and directed
Supply and Replace Brake coil, epoxy coated 440 volts suitable for EOT crane capacity 5 to 10 Ton suitable for 5" breake assembly complete all as specified and directed
Supply and Replace New brake coil, epoxy coated 440 volts suitable for EOT crane capacity 2 to 3 Ton suitable for 4" breake assembly complete all as specified and directed
Supply and Replace PVC cable copper conductor, multistandard 40/0.0076, 4 core with and including GI wire 6 SWG, sheet rings, binding wire for binding the cable and GI wire together on steel rings not less than at one mtr gap and stretching of GI wire and cable and binding at both ends of the crane complete all as specified and duirected.
Supply and Replace single cable trolly of EOT crane of capacity upto 20 Ton complete all as specified and directed
Supply and Replace Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 1.5 Sqmm 10 core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 4 Sqmm 4 core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 4 Sqmm 12 core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size1.5 Sqmm single core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 2.5 Sqmm single core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 4 Sqmm single core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 6 Sqmm single core complete all as specified and directed
Supply and Replace of Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 10 Sqmm single core complete all as specified and directed
Supply and Replace Cable PVC insulated and over all sheathed 1100 volts grade cable copper conductor twisted multi standard of size 2.5 Sqmm, 12 core cable complete all as specified and directed
Supply and Replace three phase DOL starter 440 volt suitable upto 7.5 HP motor with single phase preventer including making all electric connection complete all as specified and directed.
All as per Srl item No 101 here-in-before but 12 to 15 HP motor (but star delta starter)
All as per Srl item No 101 here-in-before but 15 to 25 HP motor
Material and labour for Rewinding of cut coils of burnt winding wire of Magnetic break thrust motor 3 phase 2 to 5 HP of EOT crane complete all as specified and directed
Material and labour for Rewinding of cut coils of burnt winding wire of Magnetic break thrust motor 3 phase 10 to 20 HP of EOT crane complete all as specified and directed
Supply and Replace Brake lining of existing size,for Magnetic break thrust motor 3 phase upto 20 ton EOT crane complete all as specified and directed
Supply and Replace Transformers of capacity 100 to 150 VA of input 440 volts output 110 volts/ 24 volts for EOT crane 2 to 5 Ton capacity complete all as specified and directed
All as per Srl item No 107 here-in-before but of capacity 300VA for EOT crane 10 Ton capacity
All as per Srl item No 107 here-in-before but of capacity 400VA for EOT crane 20 Ton capacity.
Supply and Replace Oil Tight Limit Switch Snap Action Type LIP-65, suitable for EOT crane capacity upto 20 Ton, making all electric connection and testing the crane complete all as specified and directed.
Supply and Replace Overload relay capacity 13.2 Amp to 19.4 Amp suitable for 10 to 20 Ton EOT crane complete all as specified and directed
All as per Srl item No 111 here-in-before but 2.4 Amp to 3.8 Amp suitable to 2 Ton EOT Crane
All as per Srl item No 112 here-in-before but 5.6 Amp to 9.2 Amp suitable to 3 to 5 Ton EOT Crane
Supply and Replace single GI wire rope of suitable dia as per site requirement complete all as specified and directed complete all as specified and directed
Supply and Replace MCB SPN, AC, 240 volts of 40 Amps, C curve, 10 kA rupturing capacity complete all as specified and directed
Supply and Replace MCB SPN, AC, 240 volts,63 Amps, C curve, 10 kA rupturing capacity complete all as specified and directed.
Supply and Replace MCB SP, AC, 240 volts of 06 to 32 Amps, C curve, 10 kA rupturing capacity complete all as specified and directed. .
Supply and Replace MCB-TPN,63 Amps 240/415 volts C curve, 10 kA,. rupturing capacity . complete all as specified and directed.
Supply and Replace Isolator 100 amps from crane panel , 415 volts, TPN, complete all as specified and directed.
Supply and Replace Steel wire rope any dia in mm made out of high carbon steel of ungalvanised coating connecting to the Hoist drum, load hook of EOT crane upto capacity 20 Ton including all fixing accessories such as nuts, bolts and washers etc, testing of crane on full load complete all as specified and directed
Supply and Replace Copper wire/strip of any dia/ size for bus bar/DSL system or any other requirement in the crane complete all as specified and directed
Supply and Replace pinion shaft from gear box approx 760 to 700 mm long of N-24 steel with middle pinion gear key slot and treated 50mm dia at both ends at pinion gear 30mm dia after pinion gear 34 mm at stop gap of bearing as per existing gear box shaft complete all as specified and directed
Supply and Replace Bearing 6308-M7X SKF as per sample in Gear Box 20 Ton complete all as specified and directed
Supply and Replace Bearing 6016 SKF as per sample in Gear Box 20 Ton complete all as specified and directed
Supply and Replace Bearing 6206 SKF as per sample in Gear Box 20 Ton complete all as specified and directed
Supply and Replace Steel coupling 5" long (as per sample/size) outer dia approx 50mm inner dia / bore 44mm with tightening nut bolts complete all as specified and directed.
Disconnecting the electric supply, dismantling and opening of thrust brake drum of EOT cranes and OCB's taking out care fully old transformer oil and refilling of the fresh transformer oil and reassembling the thrust brake drum and OCB's in its position complete all as specified and directed.
M & L for load hook repair for cranes of capacity 1 to 20 Ton including wheels , bearings,shaft etc complete with all connected accessories, complete all as specified and directed
Supply and replacement of load hook complete all as specified and directed by Eng-in-charge complete all as specified and directed
Supply and replacement of MS strip with insulator and copper strip channel suitable for moving of crane any size with accessories including reviting and welding work all as specified and directed by engineer in charge complete all as specified and directed
Supply and replacement of MS channel of wheel and phase collector with guide line for track with accessories complete all as specified and directed
Supply and replacement of Aluminum strip with insulator and copper strip channel suitable for moving of crane any size with accessories including reviting and welding work all as specified and directed by engineer in charge complete all as specified and directed
Supply and replacement of Copper strip channel suitable for moving of crane any size with accessories including reviting and welding work all as specified and directed by engineer in charge complete all as specified and directed
Supply and replacement of phase collector with guide line for track with accessories complete all as specified and directed
M & L for spray painting of synthetic enamal of single coat paint of matching color over one coat of red-oxide primer duly smooth funshing /scrubing of old paint surface including letter writing as existed of panels/ control panels of any size and complete all as specified and directed Note:- The rate is deemed to be included for any height / arrangement & full and entire completion of work
M & L for spray painting of synthetic enamal of single coat paint of matching color over one coat of red-oxide primer duly smooth funshing /scrubing of old paint surface including letter writing as existed of cranes of any capacity and complete all as specified and directed Note:- The rate is deemed to be included for any height / arrangement & full and entire completion of work
Supply and replacement panel(60.4cmX50.7cmX10.8cm) with body seven contactor nine fuse grip three over load relay with pendent box of 5 ton capacity including all accessories as per existing complete all as specified and directed
Supply and fixing of thruster motors of 5 ton capacity complete all as specified and directed
Supply and fixing of wheels including bearings & other connected accessories for 5 ton capacity of cranes including replacement of shaft complete all as specified and directed Note:- Item to be replaced with the concurence, specification and direction of OEM's of cranex/ TIB Engg/Pull mac/ Pioneer
carrying out / attending break downs / faults with respect to electrical equipments, control panels & connected items to rectify and ensure functionality of equipments located at 510 ABW by providing one skiled electrition and one helper for the above job complete all as specified and directed by Engineer-in-Charge Note :- Store required will be provided separately
Jain Traders
national engineering workshop
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .